G6L-1F-TR-DC5 Omron, G6L-1F-TR-DC5 Datasheet - Page 2

no-image

G6L-1F-TR-DC5

Manufacturer Part Number
G6L-1F-TR-DC5
Description
SMT TAPE AND REEL RELAY
Manufacturer
Omron
Series
G6Lr
Datasheet

Specifications of G6L-1F-TR-DC5

Relay Type
Telecom
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
1A
Switching Voltage
125VAC, 60VDC - Max
Coil Type
Non Latching
Coil Current
36mA
Coil Voltage
5VDC
Turn On Voltage (max)
4 VDC
Turn Off Voltage (min)
0.5 VDC
Features
Sealed - Fully
Mounting Type
Surface Mount
Termination Style
Gull Wing
Contact Material
-
Operate Time
5ms
Release Time
5ms
Coil Power
180 mW
Coil Resistance
139 Ohms
Operating Temperature
-40°C ~ 70°C
Specifications
■ Contact Ratings
Note: This value was measured at a switching frequency of 120 operations/min. This value may vary, depending on switching frequency, operating
■ Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
■ Characteristics
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
38
Contact mechanism
Rated load
Carry current
Max. operating voltage
Max. operating current
Min. permissible load - P level (See note)
Rated voltage
Rated current
Coil resistance
Pick-up voltage
Dropout voltage
Maximum voltage
Power consumption
Contact resistance (See Note 1)
Operate time (See Note 2)
Release time (See Note 2)
Insulation resistance (See Note 3)
Dielectric strength
Surge withstand
voltage
Vibration
Shock
Service life
Ambient temperature
Humidity
Weight
conditions, expected reliability level of the relay, etc. It is always recommended to double-check relay suitability under actual load conditions.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
4. The voltage measurements for Pick-up/Dropout are the values obtained for instantaneous changes in the voltage (rectangular wave).
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking the dielec-
4. The above values are initial values.
tric strength.
Item
Low Signal Relay
Item
Coil and contacts
Contacts of same
poles
Coil and contacts
Mechanical durability
Malfunction durability 10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Mechanical durability
Malfunction durability 100 m/s
Mechanical
Electrical
Item
3 VDC
60.0 mA
50.0 Ω
75% max. of rated voltage
10% min. of rated voltage
150% of rated voltage
Approx. 180 mW
G6L
100 mΩ max.
5 ms max. (approx. 1.1 ms)
5 ms max. (approx. 0.4 ms)
1,000 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min
750 VAC, 50/60 Hz for 1 min
1,500 VAC, 10 × 160 μs
10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
1,000 m/s
5,000,000 operations min. (at 36,000 operations/hour)
100,000 operations min. (with a rated load at 1,800 operations/hour)
Operating: -40°C to 70°C (with no icing or condensation)
Operating: 5% to 85% RH
Approx. 0.6 g
4.5 VDC
40.0 mA
112.5 Ω
Single crossbar
0.3 A at 125 VAC, 1 A at 24 VDC
1 A
125 VAC, 60 VDC
1 A
1 mA at 5 VDC
2
2
5 VDC
36.0 mA
139.0 Ω
Voltage Rating
G6L-1P, G6L-1F
Resistive load
12 VDC
15.0 mA
800.0 Ω
24 VDC
9.6 mA
2,504.0 Ω
130% of rated
voltage
Approx. 230 mW

Related parts for G6L-1F-TR-DC5