G6WK-1P DC24 Omron, G6WK-1P DC24 Datasheet - Page 3

HF TH RELAY

G6WK-1P DC24

Manufacturer Part Number
G6WK-1P DC24
Description
HF TH RELAY
Manufacturer
Omron
Series
G6Wr
Datasheet

Specifications of G6WK-1P DC24

Relay Type
RF
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
0.01A @ 30VAC/DC
Coil Type
Latching, Dual Coil
Coil Current
15mA
Coil Voltage
24VDC
Control On Voltage (max)
19.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Form
1 Form C
Power Consumption
360 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6WK-1PDC24
G6WK1PDC24
■ Characteristics
Note: 1. The above values are initial values.
Engineering Data
Note: “Maximum voltage” is the maximum
Contact resistance (See note 2)
Operate (set) time (See note 3)
Release (reset) time (See note 3)
Minimum set/reset signal width
Insulation resistance (See note 4)
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Ambient Temperature vs.
Maximum Voltage
250
200
150
100
50
0
−40
2. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
3. Values in parentheses are typical values.
4. The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those used for checking the dielectric strength.
voltage that can be applied to the relay
coil.
−20
0
20
Ambient temperature (°C)
Item
40
Coil and contacts
Coil and ground,
contacts and ground
Contact of same
polarity
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
60
80
100
100
Ambient Temperature vs.
Must Set or Must Reset Voltage
90
80
70
60
50
40
30
20
10
−60
0
DISCONTINUED
−40
100 mΩ max.
10 ms max. (Approx. 3.5 ms) 10 ms max. (Approx. 2.5 ms)
10 ms max. (Approx. 2.5 ms)
-----
1,000 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min
500 VAC, 50/60 Hz for 1 min
500 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 1.5-mm double amplitude
10 to 55 Hz, 2-mm double amplitude
1,000 m/s
500 m/s
1,000,000 operations min. (at 36,000 operations/hour)
300,000 operations min. (with a rated load at 1,800 operations/hour)
100,000 operations min. (2.5GHz, 50 Ω, 10 W)
Operating: -40°C to 70°C (with no icing or condensation)
Operating: 5% to 85%
Approx. 3 g
−20
G6W-1F, G6W-1P
Non-latching
2
2
0
Ambient temperature (°C)
20
Max. estimated value
40
Must set voltage
Must reset voltage
60
max.
avg.
max.
avg.
min.
min.
min.
80 100
12 ms
High-frequency Relay
G6WU-1F, G6WU-1P
Single-coil latching
Conditions: Shock is applied in ±X, ±Y, and
±Z directions three times each with and
without energizing the relays to check the
number of contact malfunctions.
Shock direction
Y
Y'
1,000
1,000
X
Z'
X
X'
Z
Z'
Shock Malfunction
1,000
200
400
600
800
Y
Y'
1,000
800
600
400
200
G6WK-1F, G6WK-1P
G6W
Dual-coil latching
Unit: m/s
Sample: G6WK-1P 4.5 VDC
Number of Relays: 10
Not
energized
Energized
2
1,000
1,000
Z
X'
329

Related parts for G6WK-1P DC24