Specifications of H3YN-4 AC24

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
4PDT (4 Form C)
Delay Time
0.1 Sec ~ 10 Min
Output Type
Mechanical Relay
Contact Rating @ Voltage
3A @ 250VAC
Voltage - Supply
24VAC
Mounting Type
Socket
Termination Style
Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3YN-4AC24
H3YN4AC24
Specifications
■ Ratings
Note: 1. Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Times for details.
Time ranges
Rated supply voltage (See note 5.)
Pin type
Operating mode
Operating voltage range
Reset voltage
Power consumption
Control outputs
2. Single-phase, full-wave-rectified power supplies can be used.
3. When using the H3YN continuously in any place where the ambient temperature is in a range of 45°C to 50°C, supply 90% to 110% of
4. Set the reset voltage as follows to ensure proper resetting.
5. Refer to Safety Precautions for All Timers when combining the Timer with an AC 2-wire proximity sensor.
the rated supply voltages (supply 95% to 110% with 12 VDC type).
100 to 120 VAC: 10 VAC max.
200 to 230 VAC: 20 VAC max.
100 to 110 VDC: 10 VDC max.
Item
0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min max.
selectable)
24, 100 to 120, 200 to 230 VAC (50/60 Hz) (See note 1.)
12, 24, 48, 100 to 110, 125 VDC (See note 2.)
Plug-in
ON-delay, interval, flicker OFF start, or flicker ON start (selectable with DIP switch)
85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage)
(See note 3.)
10% min. of rated supply voltage (See note 4.)
100 to 120 VAC: Relay ON: Approx. 1.8 VA (1.6 W) at 120 VAC, 60 Hz
200 to 230 VAC: Relay ON: Approx. 2.2 VA (1.8 W) at 230 VAC, 60 Hz
24 VAC:
12 VDC:
24 VDC:
48 VDC:
100 to 110 VDC: Relay ON: Approx. 1.6 W at 110 VDC
125 VDC:
DPDT: 5 A at 250 VAC, resistive load (cosφ = 1)
4PDT: 3 A at 250 VAC, resistive load (cosφ = 1)
H3YN-2/-4/-4-Z
Relay OFF: Approx. 1 VA (0.6 W) at 120 VAC, 60 Hz
Relay OFF: Approx. 1.5 VA (1.1 W) at 230 VAC, 60 Hz
Relay ON: Approx. 1.8 VA (1.4 W) at 24 VAC, 60 Hz
Relay OFF: Approx. 0.3 VA (0.2 W) at 24 VAC, 60 Hz
Relay ON: Approx. 1.1 W at 12 VDC
Relay OFF: Approx. 0.1 W at 12 VDC
Relay ON: Approx. 1.1 W at 24 VDC
Relay OFF: Approx. 0.1 W at 24 VDC
Relay ON: Approx. 1.2 W at 48 VDC
Relay OFF: Approx. 0.3 W at 48 VDC
Relay OFF: Approx. 0.4 W at 110 VDC
Relay ON: Approx. 1.6 W at 125 VDC
Relay OFF: Approx. 0.4 W at 125 VDC
0.1 min to 10 h (1 min, 10 min, 1 h, or 10 h max.
selectable)
H3YN-21/-41/-41-Z
H3YN
3

Related parts for H3YN-4 AC24