P2RVM-020B Omron, P2RVM-020B Datasheet - Page 10

Black 2-Pole Cross Bar

P2RVM-020B

Manufacturer Part Number
P2RVM-020B
Description
Black 2-Pole Cross Bar
Manufacturer
Omron
Series
G2RVr
Type
Jumperr
Datasheets

Specifications of P2RVM-020B

Accessory Type
Jumpers
Color
Black
Number Of Contacts
2POS
Number Of Contact Rows
1
Gender
M
Body Orientation
Straight
Current Rating (max)
32A
Housing Color
Black
Associated Relay Series
G2RV
Number Of Poles
2
Termination Style
Pin
Mounting Style
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
G2RV Sockets
For Use With
Z2559 - RELAY PWR SPDT 6A 24VDC DIN SKTZ2558 - RELAY PWR SPDT 6A 12VDC DIN SKTZ2557 - RELAY PWR SPDT 6A 24VDC DIN SKTZ2556 - RELAY PWR SPDT 6A 48VAC/VDCZ2555 - RELAY PWR SPDT 6A 230VAC DIN SKTZ2554 - RELAY PWR SPDT 6A 110VAC DIN SKTZ2535 - RELAY PWR 6A 24VDC W/DIN SKTZ2534 - RELAY PWR 6A 12VDC W/DIN SKTZ2533 - RELAY PWR 6A 24VAC W/DIN SKTZ2532 - RELAY PWR 6A 48VDC/VAC W/DIN SKTZ2531 - RELAY PWR 6A 230VAC W/DIN SKTZ2530 - RELAY PWR 6A 110VAC W/DIN SKT
Lead Free Status / Rohs Status
Supplier Unconfirmed
Other names
P2RVM020B
Z2674

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P2RVM-020B
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Precautions
■ Precautions for Connection
• Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components
• Do not insert the screwdriver at an angle. Doing so may break the side of socket and result in a short-circuit.
• Do not insert two or more wires in the hole. Wires may come in contact with the spring causing a temperature rise or be subject to sparks.
• Insert the screwdriver along the hole wall as shown below.
• If lubricating liquid, such as oil, is present on the tip of screwdriver, the screwdriver may fall out resulting in injury to the operator.
• Insert the screwdriver into the bottom of the hole. It may not be possible to connect cables properly if the screwdriver is inserted incorrectly.
■ General Precautions
• Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance.
• Confirm that the socket is securely attached to the mounting track before wiring. If the socket is mounted insecurely it may fall and injure
• Insure that the socket is not charged during wiring and maintenance. Not doing so may result in electric shock.
• Do not pour water or cleansing agents on the product. Doing so may result in electric shock.
• Do not use the socket in locations subject to solvents or alkaline chemicals.
• Do not use the socket in locations subject to ultraviolet light (e.g., direct sunlight). Doing so may result in markings fading, rust, corrosion, or
• Do not dispose of the product in fire.
■ Removing from Mounting Rail
To remove the socket from the mounting rail, insert the tip of screwdriver in the fixture rail, and move it in the direction shown below.
■ Wiring Procedure for G2RV-SL500 series
Wire insertion
Insert the exposed conductor into the connection hole.
No other tools are required.
Note: In case of wiring stranded wires without ferrules screwdriver
10
(e.g., deformation of the clamp spring or cracks in the housing) or cause deterioration of insulation.
(There are two wiring holes for each terminal.)
the operator.
resin deterioration.
should be inserted before inserting the wire. Screwdriver
should be removed after fully insertion of the wire.
Slim Relay
G2RV
Screwdriver hole
Wire connection hole
Wire
Wire removal
Insert the specified screwdriver into the release hole.
Removing wire.
Removing screwdriver.

Related parts for P2RVM-020B