G32J-CA20 Omron, G32J-CA20 Datasheet - Page 15

no-image

G32J-CA20

Manufacturer Part Number
G32J-CA20
Description
AUXILIARY CONTACT BLCOK 2NO
Manufacturer
Omron
Datasheet

Specifications of G32J-CA20

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G32JCA20
■ Accessories (Order Separately)
Auxiliary Contact Blocks
Mounting
1. Insert the connector and hooks on the Auxiliary Contact Block
2. Press down on the Auxiliary Contact Block in the direction of
3. To wire the Auxiliary Contact Block, use sheathed wire (length of
Removing
Specifications
G32J-CA10
G32J-CA20
G32J-CA01
G32J-CA11
1. Gradually pull out the connector on
2. Pull the Auxiliary Contact Block in the
3. Pull the Auxiliary Contact Block in the
1NO
2NO
1NC
1NO/1NC
Control circuit method Electromagnetic relay
Current specifications
Rated operating
current
(G32J-CA) into the mounting holes of the G3JA. When doing so,
be careful that the connector terminals do not bend.
arrow 2 in the figure until you hear a click.
stripped wire: 9 mm) with a core thickness of 0.5 to 2.5 mm
(AWG18 to AWG14). Use a tightening torque of 1.0 to 1.1 N·m.
the top part of the Auxiliary Contact
Block (G32J-CA) in the direction of
arrow 1 in the figure.
direction of arrow 2 in the figure.
direction of arrow 3 in the figure and
remove it.
Contacts
Item
23
33
23
11
11
23
Contact form
Auxiliary Contact
Blocks
AC/DC
2.5 A, 300 VAC
Specifications
24
34
24
12
12
24
G32J-CA10
G32J-CA20
G32J-CA01
G32J-CA11
Model
2
Fan
G32J-CF64
It is possible to perform switching four times
per hour without a fan if the G3JA is used at
the rated current in an ambient temperature
of 50°C max. with a sine current of 300%, a
start time of 15 s, and an ON time ratio of
70% max. If a fan is used, switching can be
performed ten times per hour under the
same conditions.
Mounting
1. Mount the fan so that the arrow on the surface of the Fan (G32J-
2. Insert the fan connector into the G3JA connector until it clicks into
3. Mount the fan on the G3JA.
Round Terminal Block Adaptor
G32J-TA10
This is a terminal block adaptor for
wiring with round crimp terminals.
Mounting
Once the Terminal Block Adaptor for Round Terminals is wired,
mount it to the main circuit terminals of the G3JA. If wiring is
performed after mounting the Terminal Block Adaptor for Round
Terminals on the G3JA, tighten the screws again on the main
terminals of the G3JA and the Terminal Block Adaptor to the
specified tightening torque once wiring is completed.
Note: 1. The Round Terminal Block
CF64) is in the direction shown in the figure.
place.
2. The mounting strength of the
3. Tighten the screws to the specified torque.
Adaptor (G32J-TA10) is
delivered with the cover
removed.
cover on the Round Terminal
Block Adaptor has been
increased to prevent it from
becoming removed or falling
off.
Remove the cover by inserting
a flat-head screwdriver into the
cover bump on the back of the Round Terminal Block
Adaptor and making a gap. Be careful not to become injured
when removing the cover.
The tightening torque for mounting the Round Terminal
Block Adaptor to the G3JA is 2.3 to 3.4 N·m.
The tightening torque for wiring the Round Terminal Block
Adaptor is G3JA is 0.98 to 1.37 N·m.
Fan
13
Three, M4
23
G3JA-C
10
15

Related parts for G32J-CA20