MLH500PSL01A Honeywell Sensing and Control, MLH500PSL01A Datasheet

MLH SERIES ALL METAL PRESSURE SENSOR, SEALED GAGE, AMPLIFIED, 0 PSI TO 500 PSI PRESSURE RANGE, 1/4-18 NPT PORT STYLE, 0.5 VDC TO 4.5 VDC RATIOMETRIC OUTPUT TYPE, 1 M CABLE TERMINATION TYPE

MLH500PSL01A

Manufacturer Part Number
MLH500PSL01A
Description
MLH SERIES ALL METAL PRESSURE SENSOR, SEALED GAGE, AMPLIFIED, 0 PSI TO 500 PSI PRESSURE RANGE, 1/4-18 NPT PORT STYLE, 0.5 VDC TO 4.5 VDC RATIOMETRIC OUTPUT TYPE, 1 M CABLE TERMINATION TYPE
Manufacturer
Honeywell Sensing and Control
Series
MLHr
Datasheet

Specifications of MLH500PSL01A

Pressure Type
Sealed Gauge
Operating Pressure
500 PSI
Port Size
Male, 1/4" (6.35mm) NPT
Output
0.5 ~ 4.5V
Voltage - Supply
5V
Termination Style
Cable 3'
Operating Temperature
-40°C ~ 125°C
Package / Case
Cylinder, Metal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
480-2611
DESCRIPTION
MLH Series pressure sensors combine Application Specific
Integrated Circuit (ASIC) technology with a media isolated,
metal diaphragm design. This digitally compensated sensor
offers value and performance, making it the ideal pressure
sensing solution for demanding applications. Fully temperature
compensated, calibrated and amplified, the MLH is available in
50 psi to 8,000 psi pressure ranges.
MLH sensors deliver ±0.25% full scale accuracy Best Fit
Straight Line (BFSL) and as low as 2% total error over a
temperature range of -40 °C to 125 °C [-40 °F to 257 °F].
Industry standard connectors and process ports are offered for
enhanced reliability and user flexibility.
FEATURES
All metal wetted parts for use in wide variety of fluid
applications
No internal elastomeric seals mean no o-ring compatibility
issues
Amplified outputs eliminate cost of external amplifiers
Input reverse voltage protection guards against mis-wiring
Less than 2 ms response time provides accurate, high
speed measurement
Rated IP65 or better for protection from harsh environments
The MLH has six standard output options:
A.
B.
C. 1 Vdc to 6 Vdc regulated
D. 0.25 Vdc to 10.25 Vdc regulated
E.
G. 1 Vdc to 5 Vdc regulated
POTENTIAL APPLICATIONS
Compressors
Refrigeration and HVAC/R
General industrial
General hydraulics
Multiple transportation applications including braking and
alternate fuels
Medical
0.5 Vdc to 4.5 Vdc ratiometric from 5 Vdc excitation
4 mA to 20 mA
0.5 Vdc to 4.5 Vdc regulated

Related parts for MLH500PSL01A

MLH500PSL01A Summary of contents

Page 1

DESCRIPTION MLH Series pressure sensors combine Application Specific Integrated Circuit (ASIC) technology with a media isolated, metal diaphragm design. This digitally compensated sensor offers value and performance, making it the ideal pressure sensing solution for demanding applications. Fully temperature compensated, ...

Page 2

Table 1. Pressure Range Specifications Pressure 50 100 Proof pressure 150 300 Burst pressure 500 1000 Pressure 6 10 Proof pressure 18 30 Burst pressure 60 100 Note: 1. Comparable metric units follow same proof and burst specifications. Table 2. ...

Page 3

... Refer to the “How to Order” on previous page for possible combinations. Contact your Honeywell representative for details. 250 Ohm Load Operating and Temperature Compensated Area for Output Supply Voltage (Vdc) Pin Voltage Current a + excitation + excitation b output - excitation c common no connection Honeywell Sensing and Control 30 3 ...

Page 4

Nomenclature and Order Guide MLH Series Pressure psi bar Range 050 500 006 100 100 01K 010 160 150 02K 016 250 200 03K 025 350 250 05K 040 500 300 08K 060 550 Unit P ...