Specifications of SCC15D

Pressure Type
Differential
Operating Pressure
15 PSI
Port Size
Male, 0.09" (2.28mm) Tube, Dual
Output
40 ~ 95mV
Termination Style
PCB
Operating Temperature
-40°C ~ 85°C
Package / Case
4-SIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
480-2859
SCC Series
SPECIFICATION CHARACTERISTICS (Maximum Ratings for All Devices)
Supply current, I
Compensated temperature range
Operating temperature range
Storage temperature range
Humidity
Lead temperature
Common-mode pressure
PERFORMANCE CHARACTERISTICS (Individual Models) I
Part
Number
SCC05(D,G)
SCC15A
SCC15(D,G)
SCC30(D,G)
SCC100A
SCC100(D,G)
SCC300A
PERFORMANCE SPECIFICATIONS (All Models) I
Zero Pressure Offset
Combined Linearity, Hysteresis and Repeatability
Long Term Stability of Offset and Span
Response Time (10 % to 90 %)
Input Impedance
Output Impedance
Specification Notes:
Note 1: Reference Conditions; Supply Current = 1.0 mA; TA = 25 °C [77 °F], Common-mode Line Pressure = 0 psig, Pressure Applied to P1, unless otherwise noted.
Note 2: Accuracy is the sum of Hysteresis and Linearity. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and
Note 3: This is the maximum temperature shift for span when measured between 0 °C and 50 °C [32 °F to 122 °F] relative to the 25 °C [77 °F] reading. Typical
Note 4: Temperature effect on span and offset are guaranteed by design. Therefore these parameters are not 100 % tested.
Note 5: This is the maximum temperature shift for offset when measured at 0 °C and 50 °C [32 °F to 122 °F] divided by the temperature difference.
Note 6: Span is the algebraic difference between the output voltage at full-scale pressure and the ouput at zero pressure.
Note 7: The SCC100D devices can only be used in a forward gauge mode. Application of more than 30 psig to the back side of any of the SCC Series devices can result
Note 8: The zero pressure offset is 30 to -20 mV max. form parts SCCxxxGD2 and SCCxxDD4 devices.
Note 9: Maximum difference in output at any pressure with the operating pressure range and temperature within 0 °C and 50 °C [32 °F to 122 °F].
Note 10: Response time for a 0 psi to full-scale span pressure step change. 10 % to 90 % rise time.
2
decreasing pressure. Linearity refers to the best straight line fit as measured for the offset, full-scale and ½ full-scale pressure at 25 °C [77 °F].
temperature coefficients for span and resistance are -2200 ppm/°C and 2200 ppm/°C respectively.
in device failure. On the SCC100GD2 pressure can only be applied to the back side of the die. No pressure I accessible from the front/top side of die.
a) 100 temperature cycles, 0 °C and 50 °C [32 °F to 122 °F]
b) 1.0 million pressure cycles, 0 psi to full-scale span.
www.honeywell.com/sensing
(7)
S
0 psid to 15 psid (g)
0 psid to 30 psid (g)
0 psid to 5 psid (g)
0 psia to 100 psia
0 psig to 100 psig
0 psia to 300 psia
Pressure Range
0 psia to 15 psia
(8)
Operating
(10)
1.5 mA
0 °C to 50 °C [32 °F to 122 °F]
-40 °C to 85 °C [-40 °F to 185 °F]
-55 °C to 125 °C [-67 °F to 257 °F]
0 % to 100 % RH
250 °C [482 °F] Soldering 2 sec to 4 sec
150 psi
(9)
Over Pressure
Maximum
150 psia
150 psig
450 psia
30 psia
60 psi
20 psi
30 psi
(2)
s
=10.0 Ma, T
-30.0
Min.
4.00
4.00
s
Accuracy
=1.0 mA, T
0.50 %
0.50 %
0.50 %
0.50 %
0.50 %
0.50 %
0.50 %
a
=25 °C [77 °F]
(2)
A
Typ.
-10.0
0.25
0.10
0.10
5.00
5.00
=25 °C [77 °F]
0 °C to 50 °C
Effect
on Span
1.50 %
1.50 %
1.50 %
1.50 %
1.50 %
1.50 %
1.50 %
(3, 4)
Max.
20.0
0.50
6.50
6.50
(1)
0 °C to 50 °C
on Offset
Effect
30 µV/°C
40 µV/°C
40 µV/°C
60 µV/°C
30 µV/°C
90 µV/°C
50 µV/°C
(5, 4)
% FSO
kOhm
kOhm
Unit
mV
mV
ms
Full-Scale
Span
60-150
85-225
85-225
50-120
25-65
40-95
40-95
mV