DS12R887-5 Maxim Integrated Products, DS12R887-5 Datasheet - Page 12

no-image

DS12R887-5

Manufacturer Part Number
DS12R887-5
Description
Real Time Clock RTC with Constant Vo ltage Trickle Charge
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS12R887-5

Function
Clock, Calendar
Rtc Memory Size
114 B
Supply Voltage (max)
5.5 V
Supply Voltage (min)
4.5 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Rtc Bus Interface
Multiplexed
Package / Case
BGA
Time Format
HH:MM:SS, Binary
Date Format
DW:DM:M:Y, Binary
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS12R887-5
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS12R887-5
Manufacturer:
MAXIM/美信
Quantity:
20 000
The accuracy of the clock is dependent upon the accu-
racy of the crystal and the accuracy of the match
between the capacitive load of the oscillator circuit and
the capacitive load for which the crystal was trimmed.
Additional error is added by crystal frequency drift
caused by temperature shifts. External circuit noise cou-
pled into the oscillator circuit can result in the clock run-
ning fast. Figure 2 shows a typical PC board layout for
isolation of the crystal and oscillator from noise. Refer to
Application Note 58: Crystal Considerations with Dallas
Real-Time Clocks for more detailed information.
tory to an accuracy of ±1 minute per month at +25°C.
The real-time clock continues to operate, and the RAM,
time, calendar, and alarm memory locations remain
nonvolatile regardless of the V
remain within the minimum and maximum limits when
V
V
ble after t
lator countdown chain is not in reset (Register A). This
time allows the system to stablize after power is
applied. If the oscillator is not enabled, the oscillator-
enable bit is enabled on power-up, and the device
becomes immediately accessible.
The time and calendar information is obtained by read-
ing the appropriate register bytes. The time, calendar,
and alarm are set or initialized by writing the appropri-
ate register bytes. Invalid time or date entries result in
undefined operation. The contents of the 10 time, cal-
endar, and alarm bytes can be either binary or binary-
coded decimal (BCD) format.
The day-of-week register increments at midnight, incre-
menting from 1 through 7. The day-of-week register is
used by the daylight saving function, so the value 1 is
defined as Sunday. The date at the end of the month is
Real-Time Clocks
The encapsulated DIP modules are trimmed at the fac-
12
CC
PF
Clock Accuracy for DS12887, DS12887A,
(power-fail trip point), the device becomes accessi-
is not applied. When V
____________________________________________________________________
REC
Time, Calendar, and Alarm
—if the oscillator is running and the oscil-
Power-Down/Power-Up
DS12C887, DS12C887A Only
CC
Clock Accuracy
CC
Considerations
is applied and exceeds
input level. V
Locations
BAT
must
automatically adjusted for months with fewer than 31
days, including correction for leap years.
Before writing the internal time, calendar, and alarm reg-
isters, the SET bit in Register B should be written to logic
1 to prevent updates from occurring while access is
being attempted. In addition to writing the 10 time, calen-
dar, and alarm registers in a selected format (binary or
BCD), the data mode bit (DM) of Register B must be set
to the appropriate logic level. All 10 time, calendar, and
alarm bytes must use the same data mode. The SET bit
in Register B should be cleared after the data mode bit
has been written to allow the RTC to update the time and
calendar bytes. Once initialized, the RTC makes all
updates in the selected mode. The data mode cannot be
changed without reinitializing the 10 data bytes. Tables
2A and 2B show the BCD and binary formats of the time,
calendar, and alarm locations.
The 24-12 bit cannot be changed without reinitializing the
hour locations. When the 12-hour format is selected, the
higher-order bit of the hours byte represents PM when it
is logic 1. The time, calendar, and alarm bytes are always
accessible because they are double-buffered. Once per
second the seven bytes are advanced by one second
and checked for an alarm condition.
If a read of the time and calendar data occurs during
an update, a problem exists where seconds, minutes,
hours, etc., may not correlate. The probability of read-
ing incorrect time and calendar data is low. Several
methods of avoiding any possible incorrect time and
calendar reads are covered later in this text.
Figure 2. Layout Example
LOCAL GROUND PLANE (TOP LAYER)
NOTE: AVOID ROUTING SIGNAL LINES
IN THE CROSSHATCHED AREA
(UPPER LEFT QUADRANT) OF
THE PACKAGE UNLESS THERE IS
A GROUND PLANE BETWEEN THE
SIGNAL LINE AND THE DEVICE PACKAGE.
CRYSTAL
GND
X1
X2