SPM0204HE5 Knowles Acoustics, SPM0204HE5 Datasheet - Page 9

Touch Sensor

SPM0204HE5

Manufacturer Part Number
SPM0204HE5
Description
Touch Sensor
Manufacturer
Knowles Acoustics
Datasheet

Specifications of SPM0204HE5

Transducer Function
Microphone
Device Type
Mini Microphone
Directivity
Omni
Connector Type
SMD
Sensitivity
-42
Output Impedance
300ohm
Length
4.72mm
Termination Type
SMD
No. Of Pins
4
Operating Temperature Range
-40°C To +100°C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SPM0204HE5-PB-6
Manufacturer:
KNOWLES
Quantity:
8 829
Part Number:
SPM0204HE5-PB-6
Manufacturer:
KNOWLES
Quantity:
20 000
Part Number:
SPM0204HE5-PB-T
Manufacturer:
ALPS
Quantity:
8 473
Note: After test conditions are performed, the sensitivity of the microphone shall not deviate more
than 3dB from its initial value.
Thermal Shock
High Temperature Storage
Test
Low Temperature Storage
Test
High Temperature Operating
Test
Low Temperature Operating
Test
Humidity Test
Vibration Test
Electrostatic Discharge
Reflow
Mechanical Shock
13. RELIABILITY SPECIFICATIONS
Test
Knowles Acoust ics, a division of Knowles
Microphone unit must operate when exposed to air-to-air thermal shock 100 cycles,
from –40ºC to +125ºC. (IEC 68-2-4),
Microphone unit must maintain sensitivity after storage at +105ºC for 1,000 hours. (IEC
68-2-2 Test Ba)
Microphone unit must maintain sensitivity after storage at –40ºC for 1,000 hours. (IEC
68-2-1 Test Aa)
Microphone unit must operate within sensitivity specifications for 1,000 hours at 105ºC.
(IEC 68-2-2 Test Ba)
Microphone unit must operate within sensitivity specifications for 1,000 hours at –40ºC.
(IEC 68-2-1 Test Aa)
Tested under Bias at 85ºC/85% R.H. per JESD22-A101A-B
Microphone unit must operate under test condition: 4 cycles, from 20 to 2,000 Hz in
each direction (x,y,z), 48 minutes, using peak acceleration of 20 G (+20%, -0%). (MIL
883E, method 2007.2, A)
Tested to 8kV direct contact discharge to the case and tested to 2kV direct contact to
I/O terminals.
Microphone is tested to 5 passes through reflow oven, with microphone mounted
upside-down under conditions of 260ºC for 30 seconds maximum.
Microphone must operate after exposure to shock test of 10,000 G per IEC 68-2-27, Ea.