JCT-3E Cooper/Bussmann, JCT-3E Datasheet - Page 2

Fuses 15500V 3A

JCT-3E

Manufacturer Part Number
JCT-3E
Description
Fuses 15500V 3A
Manufacturer
Cooper/Bussmann
Type
Limiterr
Datasheet

Specifications of JCT-3E

Voltage Rating (vac)
15500V
Current Rating
3A
Mounting
Surface Mount
Product Depth (mm)
Not Requiredmm
Product Height (mm)
Not Requiredmm
Voltage Rating
15.5 KVolts
Termination Style
Cartridge
Fuse Type
Time Delay / Slow Blow
Dimensions
17 1/2 in L x 1 3/5 in W
Product
Medium Voltage Fuse
Interrupt Rating
130 KAmps / 80 KAmps
Lead Free Status / RoHS Status
Compliant
Lead Free Status / RoHS Status
Compliant
Dimensional Data
Specifications
Buss
Catalog No.
2400V; E-Rated Fuse; Indicating
JCD-1/2E
JCD-1E
JCD-2E
JCD-5E
2400/4800V; E-Rated Fuse; Non-Indicating
JCW-1/2E
JCW-1E
JCW-2E
JCW-3E
JCW-4E
JCW-5E
5500V; E-Rated Fuse; Non-Indicating
JCE-1/2E
JCE-1E
JCE-2E
JCE-3E
JCE-4E
JCE-5E
4800V; E-Rated Fuse; Indicating
JCQ-1/2E
JCQ-1E
JCQ-1-1/2E
JCQ-3E
JCQ-5E
JCQ-10E
7200V; E-Rated Fuse; Indicating
JCI-1/2E
JCI-3E
JCI-5E
JCI-10E
14,400V; E-Rated Fuse; Indicating
JCT-1/2E
JCT-1E
JCT-1-1/2E
JCT-3E
JCT-5E
JCT-10E
Fuse clip for 1.6” Diameter Fuses - 1A0835
Fuse clip for 0.81” Diameter Fuses - 1A1837
E-Rated Fuses
For Potential & Small Power Trans.
Medium Voltage
The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled. This bulletin is intended to clear-
ly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any prod-
ucts and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected,
it should be tested by the user in all possible applications.
2-27-02
C
SB02090
A
Amperage
.50E
1.0E
2.0E
5.0E
.5E
1E
2E
3E
4E
5E
.5E
1E
2E
3E
4E
5E
.5E
1.0E
1.5E
3.0E
5.0E
10.0E
.50E
3.0E
5.0E
10.0E
.5E
1.0E
1.5E
3.0E
5.0E
10.0E
Maximum
Design Voltage
2750V
2750V
2750V
2750V
2750V/5500V
2750V/5500V
2750V/5500V
2750V/5500V
2750V/5500V
2750V/5500V
5500V
5500V
5500V
5500V
5500V
5500V
5500V
5500V
5500V
5500V
5500V
5500V
8300V
8300V
8300V
8300V
15500V
15500V
15500V
15500V
15500V
15500V
B
Dimensions (Inches)
A
4.5
4.5
4.5
4.5
7.31
7.31
7.31
7.31
7.31
7.31
5.6
5.6
5.6
5.6
5.6
5.6
9.5
9.5
9.5
9.44
9.44
9.44
9.5
12.88
12.88
12.88
12.93
12.93
12.93
17.5
17.5
17.5
B
0.8
0.8
0.8
0.8
1.56
1.56
1.56
1.56
1.56
1.56
0.81
0.81
0.81
0.81
0.81
0.81
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
C
0.63
0.63
0.63
0.63
1.38
1.38
1.38
1.38
1.38
1.38
0.63
0.63
0.63
0.63
0.63
0.63
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
Construction
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
JCQ, JCI, & JCT
JCD, JCW, JCE
Maximum Interrupting Capacity
Amps (Asym.)
100,000
63,000
63,000
40,000
60,000
60,000
60,000
60,000
60,000
60,000
60,000
60,000
60,000
60,000
60,000
60,000
130,000
130,000
130,000
130,000
130,000
130,000
130,000
130,000
130,000
130,000
130,000
130,000
130,000
130,000
130,000
130,000
Bussmann
Form No. JCD, JCW, JCE,
JCQ, JCI, and JCT
Data Sheet: 6002
Amps (Sym.)
63,000
40,000
40,000
25,000
40,000
40,000
40,000
40,000
40,000
40,000
50,000
50,000
50,000
50,000
50,000
50,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
Page 2 of 2
®

Related parts for JCT-3E