Fuses 250V 5A Super Lag Renewable

RES-5

Manufacturer Part Number
RES-5
Description
Fuses 250V 5A Super Lag Renewable
Manufacturer
Cooper/Bussmann
Type
Renewabler
Datasheet

Specifications of RES-5

Acting
Super Time Lag
Voltage Rating (vac)
600V
Current Rating
5A
Mounting
Surface Mount
Product Depth (mm)
Not Requiredmm
Product Height (mm)
Not Requiredmm
Voltage Rating
250 Volts
Fuse Size / Group
Class H
Termination Style
Cartridge
Fuse Type
Long Time Delay / Slow Blow
Dimensions
5 in L x 13/16 in W
Product
Industrial Power Fuse
Interrupt Rating
10 KAmps
Lead Free Status / RoHS Status
Not Compliant
Lead Free Status / RoHS Status
Not Compliant
CATALOG SYMBOLS: REN (250V); RES (600V)
TIME-LAG
1 TO 600 AMPERES
250 AND 600 VOLTS AC (OR LESS)
NON-CURRENT LIMITING
INTERRUPTING RATING–10,000A RMS SYM.
CLASS H
Super-Lag Renewable Fuses
and Fuse Links
250 and 600 Volts, 1-600 Amps
11-27-00
J00269
Dimensional Data REN (250V)
Dimensional Data RES (600V)
• Designed for easy replacement.
• No multiple links to complicate replacement.
• Buss SUPER-LAG Renewable fuses with longer time-lag
• SUPER-LAG fuses are used in circuits of industrial and
• These fuses are generally sized at the ampere rating of non-
1/10A to 30A
35A to 60A
70A to 100A
1/10A to 30A
70A to 100A
35A to 60A
than other Class H fuses of this type can better sustain over-
loads without needlessly opening.
commercial structures where maximum short-circuit currents
are of a low level (below 10,000 amperes) and frequent out-
ages dictate the economy of the “renewable” type fuse.
inductive circuits and 300% for motor circuits.
2"
3"
5"
5.5"
.56"
5.88"
7.88"
.81"
0.81"
1.06"
110A to 200A
225A to 400A
450A to 600A
110A to 200A
225A to 400A
450A to 600A
REN and RES
7.13"
9.63"
(LKN & LKS)
11.63"
8.63"
Bussmann
10.38"
13.38"
Form No. REN/RES
BIF Doc #1028
Page 1 of 4
®

Related parts for RES-5

RES-5 Summary of contents

Page 1

... SUPER-LAG fuses are used in circuits of industrial and commercial structures where maximum short-circuit currents are of a low level (below 10,000 amperes) and frequent out- ages dictate the economy of the “renewable” type fuse. • These fuses are generally sized at the ampere rating of non- inductive circuits and 300% for motor circuits ...

Page 2

... LKS 450–600 * Weight per carton. Bussmann REN and RES (LKN & LKS) RES-70 RES-225 RES-80 RES-250 RES-90 RES-300 RES-100 RES-350 RES-110 RES-400 RES-125 RES-450 RES-150 RES-500 RES-175 RES-600 RES-200 — Weight* Lbs. Kg. 10 0.18 0.082 10 0.36 0.163 5 4.16 1.886 1 1.83 ...

Page 3

... Super-Lag Renewable Fuses and Fuse Links 250 Volts, 1-600 Amps Time-Current Characteristic Curves–Average Melt REN SUPER-LAG (250 VOLTS AC) 11-27-00 J00269 Bussmann ® REN and RES (LKN & LKS) Form No. REN/RES Page BIF Doc #1028 ...

Page 4

... Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been select- ed, it should be tested by the user in all possible applications ...