G2R1SDC12S Omron, G2R1SDC12S Datasheet - Page 3

Electromechanical Relay SPDT 10A 12VDC 278Ohm Socket

G2R1SDC12S

Manufacturer Part Number
G2R1SDC12S
Description
Electromechanical Relay SPDT 10A 12VDC 278Ohm Socket
Manufacturer
Omron
Type
General Purpose Relayr
Datasheet

Specifications of G2R1SDC12S

Contact Arrangement
SPDT
Dc Coil Voltage
12 V
Coil Current
43.2 mA
Mounting
Socket
Relay Construction
Non-Latching
Coil Voltage Dc
12V
Contact Form
1 Form C
Voltage Rating (vdc)
125V
Voltage Rating (vac)
440V
Dropout Volt (min)
1.8VDCV
Coil Resistance
278Ohm
Pick-up Voltage (max)
8.4VDC
Maximum Power Rating
300W/2.5KVA
Operate Time
15ms
Contact Current Rating
10A
Contact Material
Silver Cadmium Oxide
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
29mm
Product Depth (mm)
13mm
Product Length (mm)
29mm
Operating Temp Range
-40C to 70C
Pin Count
5
Mounting Style
Socket
Termination Style
Quick Connect
Package / Case
Dust Cover
Lead Free Status / Rohs Status
Compliant
Contact Ratings
Note: P level: λ
Characteristics
Note: Values in the above table are the initial values.
Approved Standards
UL 508 (File No. E41643)
CSA 22.2 No.0, No.14
(File No. LR31928)
Number of poles
Load
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value)
Contact resistance
Operate (set) time
Release (reset) time
Max. operating
frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
G2R-1-S SPDT
G2R-2-S DPDT
G2R-1-S SPDT
G2R-2-S DPDT
Model
Model
*4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is mounted.
Item
Contact
Contact
form
form
60
= 0.1 x 10
5 to 110 VDC
5 to 240 VAC
5 to 110 VDC
5 to 240 VAC
Coil ratings
Coil ratings
100 mΩ max.
15 ms max.
AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
Mechanical:
Electrical:
1,000 MΩ min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts of
same polarity
Destruction:
Malfunction:
Destruction:
Malfunction:
Mechanical:
Electrical:
Operating:
Operating:
Approx. 21 g
-6
/operation
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
1 pole
Resistive load
(cosφ = 1)
10 A at 250 VAC;
10 A at 30 VDC
10 A
440 VAC, 125 VDC
10 A
2,500 VA,
300 W
100 mA at 5 VDC
Contact ratings
Contact ratings
18,000 operations/hr
1,800 operations/hr (under rated load)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s
200 m/s
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)
–40°C to 70°C (with no icing or condensation)
5% to 85%
1 pole
2
when energized; 100 m/s
2
6 x 10
6 x 10
6 x 10
6 x 10
ations
ations
Oper-
Oper-
Inductive load
(cosφ = 0.4; L/R = 7 ms)
7.5 A at 250 VAC;
5 A at 30 VDC
1,875 VA,
150 W
3
3
3
3
IEC/VDE (EN61810)
LR
1 pole
2 poles
1 pole
2 poles
2
Contact
Number
of poles
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
when not energized
form
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 to 110 VDC
5 to 240 VDC
5 to 110 VDC
5 to 240 VDC
Coil ratings
Coil ratings
2 poles
Resistive load
(cosφ = 1)
5 A at 250 VAC;
5 A at 30 VDC
5 A
380 VAC, 125 VDC
5 A
1,250 VA,
150 W
10 mA at 5 VDC
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms)
2 poles
Contact ratings
Contact ratings
Inductive load
(cosφ = 0.4; L/R = 7 ms)
2 A at 250 VAC; 3 A at
30 VDC
500 VA,
90 W
G2R-@-S
100 x 10
100 x 10
Operations
100 x 10
100 x 10
Operations
3
3
3
3
3

Related parts for G2R1SDC12S