G5V2DC48 Omron, G5V2DC48 Datasheet - Page 2

Electromechanical Relay DPDT 2A 48VDC 4KOhm Through Hole

G5V2DC48

Manufacturer Part Number
G5V2DC48
Description
Electromechanical Relay DPDT 2A 48VDC 4KOhm Through Hole
Manufacturer
Omron
Type
Signal Relayr
Datasheet

Specifications of G5V2DC48

Contact Arrangement
DPDT
Dc Coil Voltage
48 V
Coil Current
12 mA
Mounting
Through Hole
Relay Construction
Non-Latching
Coil Voltage Dc
48V
Contact Form
2 Form C
Voltage Rating (vdc)
125V
Voltage Rating (vac)
125V
Dropout Volt (min)
2.4VDCV
Coil Resistance
4kohm
Pick-up Voltage (max)
33.6VDC
Maximum Power Rating
60W/62.5VA
Operate Time
7ms
Contact Current Rating
2A
Contact Material
Ag/Au Clad
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
11.5mm
Product Depth (mm)
10.1mm
Product Length (mm)
20.5mm
Operating Temp Range
-25C to 65C
Pin Count
8
Mounting Style
Through Hole
Termination Style
PC Pin
Package / Case
DIP
Lead Free Status / Rohs Status
Compliant
■ Coil Data
Standard Type
High-sensitivity Type
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Characteristics
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
78
3
5
6
9
12
24
48
3
5
6
9
12
24
48
Contact resistance (See note 1)
Operate time (See note 2)
Release time (See note 2)
Operating frequency
(max.)
Insulation resistance (See note 3)
Dielectric strength
Surge withstand voltage
Vibration
Shock
Ambient temperature
Humidity
Service life
Weight
Rated voltage
Rated voltage
(VDC)
(VDC)
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
2. Values in parentheses are typical values unless otherwise stated.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those for checking the dielectric strength.
4. The above values are initial values.
Low Signal Relay
Rated current
166.70
100
83.30
55.60
41.70
20.80
12
Rated current
50
30
25
16.70
12.50
8.33
6.25
(mA)
(mA)
Mechanical
Electrical
Mechanical durability 10 to 55 Hz, 1.50 mm double amplitude
Malfunction
durability
Mechanical durability 1,000 m/s
Malfunction
durability
Operating/storage
Mechanical
Electrical
18
50
72
162
288
1,152
4,000
60
166.7
240
540
960
2,880
7,680
resistance
resistance
Coil
Coil
(Ω)
(Ω)
G5V-2
Armature OFF Armature ON
0.04
0.09
0.16
0.31
0.47
1.98
7.23
Armature OFF Armature ON
0.18
0.46
0.70
1.67
2.90
6.72
20.10
50 mΩ max. (G5V-2); 100 mΩ max. (G5V-2-H1)
7 ms max. (mean value: approx. 3.5 ms)
3 ms max. (mean value: approx. 0.8 ms)
36,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles
750 VAC, 50/60 Hz for 1 minute between contacts of same poles
(500 VAC, 50/60 Hz for 1 minute between contacts of same poles for high-sensitive type)
1,500 V (10 X 160 μs) between coil and contacts (conforms to part 68 of FCC rules)
200 m/s
-25° to 70°C (“-H1” versions) with no icing
-25° to 65°C (standard versions) with no icing
5% to 85% RH
15 million operations min. (at operating frequency of 36,000 operations/hour)
100,000 operations min. (at 1,800 operations/hr). See “Characteristic Data”
Approx. 5 g
Coil inductance
Coil inductance
(Ref. value) (H)
(Ref. value) (H)
2
0.05
0.11
0.19
0.49
0.74
2.63
10.00
0.57
0.71
0.97
2.33
3.99
9.27
26.70
(approx. 20 G), 100 m/s
2
(approx. 100 G)
75% max.
75% max.
Pick-up
voltage
Pick-up
voltage
2
(approx. 10 G) for high-sensitive type
% of rated voltage
% of rated voltage
5% min.
5% min.
Dropout
Dropout
voltage
voltage
120% max.
at 23°C
180% max.
at 23°C
150% max.
at 23°C
Maximum
Maximum
voltage
voltage
Approx. 500
Approx. 580
Approx. 150
Approx. 200
Approx. 300
consumption
consumption
Power
Power