PDB-B-24-450-E-2-AD1-C Carling Technologies, PDB-B-24-450-E-2-AD1-C Datasheet

Circuit Breakers CIRCUIT BREAKER

PDB-B-24-450-E-2-AD1-C

Manufacturer Part Number
PDB-B-24-450-E-2-AD1-C
Description
Circuit Breakers CIRCUIT BREAKER
Manufacturer
Carling Technologies
Datasheet

Specifications of PDB-B-24-450-E-2-AD1-C

Product Type
Circuit Breakers
Current Rating
5 Amps
Voltage Rating
120 VoltsAC, 240 VoltsAC
Product
Hydraulic Magnetic Circuit Breakers
Actuator Type
Handle
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table B:
tection.
PD-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTOR & EARTH LEAKAGE CURRENT INTERRUPTER
UL Recognized
UL Standard 1077
UL Standard 943
Table A:
Protector.
CONFIGURATION
CONFIGURATION
Agency Certifications
Electrical
CIRCUIT
CIRCUIT
SERIES
SERIES
Carling
Technologies
Lists TUV Certified configurations and performance capabilities as a Circuit breaker incorporating residual current pro-
Lists UL Recognized & CSA Certified configurations and performance capabilities as a Component Supplementary
120-240
200-240
380-415
380-415
120/208
120/208
208-240
RATING
RATING
480Y
MAX
MAX
PD-SERIES TABLE B: CIRCUIT BREAKER WITH RESIDUAL CURRENT PROTECTION
FREQUENCY
FREQUENCY
VOLTAGE
VOLTAGE
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
Component Recognition Program as
Equipment Leakage Circuit
Interrupter and, Protectors,
Supplementary (FTTJ2, File
E177510).
Tested as Ground Fault Circuit
Interrupters for Equipment
Protection.
PHASE
PHASE
3 -Y
1
3
1
1
1
3
3
CURRENT
RATING
AMPS
AMPS
LOAD
LOAD
FULL
FULL
1-50
1-50
1-50
1-30
1-50
1-50
1-50
1-50
CURRENT RATING
www.carlingtech.com
MUST - TRIP
(MILLIAMPS)
GENERAL
PURPOSE
LEAKAGE
CURRENT
7-100mA
7-100mA
7-100mA
7-100mA
30.1-50
RATING
AMPS
---
---
---
CAPACITY (AMPS)
INTERRUPTING
BACKUP FUSE
CAPACITY (lcu)
ULTIMATE S/C
BREAKING
WITHOUT
SmartGuard is an equipment ground fault protection device that
combines hydraulic/magnetic circuit breaker and overload and
short circuit protection and ground fault protection. This breaker
senses and guards against faults to ground using a state of the
art integrated circuit. This technology detects faults and when a
fault occurs, the breaker trips and an LED illuminates. The LED
gives a clear indication that the trip occurred as a result of leak-
age. This protection helps prevent serious equipment damage
and fire.
UL / CSA
5000
5000
2000
2000
5000
2667
2000
2000
INTERRUPTING CAPACITY (AMPS)
CSA Certified
TUV Certified
CAPACITY (lcs)
SERVICE S/C
MUST - TRIP
(MILLIAMPS)
BREAKING
CURRENT
LEAKAGE
RATING
7-100
7-100
7-100
7-100
PD-Series – General Specifications
3750
2000
2000
2000
CURRENT (l m)
RESIDUAL S/C
MAKE/BREAK
1250
1000
1000
1000
Component Equipment Leakage
Current Interrupter with
Supplementary Protector, under
Class C22.2,No. 144-M91, FIle
LR47848-50
IEC 947-2 and appendix B: Circuit
Breakers incorporating Residual
Current Protection. Complies with
waveform requirements of IEC 1008-
1, Type A.
101

Related parts for PDB-B-24-450-E-2-AD1-C

PDB-B-24-450-E-2-AD1-C Summary of contents

Page 1

... SmartGuard is an equipment ground fault protection device that combines hydraulic/magnetic circuit breaker and overload and short circuit protection and ground fault protection. This breaker senses and guards against faults to ground using a state of the art integrated circuit. This technology detects faults and when a fault occurs, the breaker trips and an LED illuminates ...

Page 2

... Operating Temperature www.carlingtech.com 10,000 ON-OFF operations @ 6 per minute; with rated current and volt- age. All SmartGuard equipment leakeage circuit breakers will trip on overload or leakage to ground, even when actuator is forcibly held in the & 4 4.2 inches ( 106.7 mm) 2-pole: 3.0 inches (76.2 mm) 3-pole: 3.75 inches (95.3 mm) 4-pole: 4 ...

Page 3

Carling Technologies ™ 650 Series Voltage/ Circuit Poles 1 SERIES PD 2 SYSTEM VOLTAGE/POLES 1 System Voltage Poles A 120VAC 1Ø One plus unswitched neutral B 120/240 VAC 1Ø ...

Page 4

... PD-Series – Circuit & Terminal Diagrams CIRCUIT SCHEMATICS PDA LINE P1(L) (N) TRIPPED DUE TO TEST EARTH LEAKAGE SENSOR INDICATOR LOAD PDB PDF & PDQ (WITH UNSWITCHED NEUTRAL) P2(L) P1(N) LINE P2(L2) P1(L1) TRIPPED DUE TO EARTH LEAKAGE TEST INDICATOR SENSOR LOAD PDG & PDR (WITH SWITCHED NEUTRAL) ...

Page 5

... Carling Technologies ™ 2.250 [57.15] PDA & PDB ON I 3.000 [76.20] TRIPPED DUE TO EARTH LEAKAGE INDICATOR ON PDC & PDD I 3.750 [95.25] PDF, PDG ON I PDQ & PDR 4.500 [114.30] .649 [16.48] 2.260 [57.40] 1.125 [28.58] 2.250 [57.15] PANEL CUT-OUT DETAIL Notes: 1 All dimensions are in inches [millimeters] ...