PSS1212-9 POWER ONE, PSS1212-9 Datasheet - Page 12

no-image

PSS1212-9

Manufacturer Part Number
PSS1212-9
Description
Manufacturer
POWER ONE
Datasheet

Specifications of PSS1212-9

Output Current
12A
Input Voltage
15 to 80V
Output Voltage
12V
Output Power
144
Screening Level
Commercial
Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
71C
Product Length (mm)
168.5mm
Product Depth (mm)
111mm
Product Height (mm)
60mm
Mounting Style
Screw
Pin Count
15
Number Of Outputs
1
Lead Free Status / RoHS Status
Not Compliant
Electromagnetic Compatibility (EMC)
Electromagnetic Immunity
General condition: Case not earthed.
Table 8: Immunity type tests
Fig. 9
Typical disturbance voltage
(quasi-peak) at the input
according to EN 55011/22
measured at V
Electromagnetic Emissions
BCD20029-G Rev AA, 28-Apr-09
Phenomenon
Direct transients
Electrostatic
discharge
Electromagnetic
field
Electrical fast
transients/burst
Surges
Conducted
disturbances
1
2
3
4
5
i = input, o = output, c = case
Not applicable for -2 models
Valid for -2 models
A = Normal operation, no deviation from specifications, B = Normal operation, temporary loss of function or deviation from specs possible
With option C, manual reset might be necessary.
i nom
2
Standard
IEC 60571-1
IEC/EN
61000-4-2
IEC/EN
61000-4-3
IEC/EN
61000-4-4
IEC/EN
61000-4-5
IEC/EN
61000-4-6
and I
®
o nom
.
Class
Level
2
2
4
3
3
3
2
4
3
3
2
3
2
3
2
2
3
2
2
3
2
3
2
3
2
3
2
3
3
contact discharge
i, o, signal wires
80
dBμV
60
40
20
0
Coupling
i/c, +i/–i
antenna
i/c, +i/–i
mode
to case
+i/–i
i/c
1
Page 12 of 20
1000 V
4000 V
2000 V
2000 V
2000 V
8000 V
6000 V
2000 V
10 VAC
1000 V
10 V/m
applied
1500 V
3000 V
4000 V
7000 V
500 V
3 VAC
3 V/m
800 V
Value
p
p
p
p
p
3
p
p
p
p
p
p
3
3
p
p
p
p
2
3
2
2
3
2
3
2
3
2
2
bursts of 5/50 ns
5 kHz rep. rate
transients with
300 ms period
duration and
15 ms burst
Waveform
1.2/50 μs
1.2/50 μs
AM 80%
AM 80%
1/50 ns
100 μs
100 ns
50 μs
1 kHz
1 kHz
5 μs
1 μs
Positive Switching Regulators
EN 55022 A
EN 55022 B
PSS, PSK Series Data Sheet
Source
imped.
100
330
150
50
12
12
07022a
1 pos. and 1 neg.
5 pos. and 5 neg.
voltage surge per
MHz
10 positive and
80 – 1000 MHz
coupling mode
coupling mode
coupling mode
0.15 – 80 MHz
transients per
60 s negative
60 s positive
10 negative
procedure
discharges
surges per
Test
www.power-one.com
oper. form.
yes
yes
yes
yes
yes
yes
In
Per-
B
B
A
A
A
A
A
5
4