CEB-35FD29 CUI Inc, CEB-35FD29 Datasheet - Page 2

BUZZER PIEZO ELEMENT 2.9KHZ 35MM

CEB-35FD29

Manufacturer Part Number
CEB-35FD29
Description
BUZZER PIEZO ELEMENT 2.9KHZ 35MM
Manufacturer
CUI Inc
Series
CEBr
Type
Feed Backr
Datasheet

Specifications of CEB-35FD29

Frequency
2.9kHz
Impedance
500 Ohm
Voltage - Input, Max
30V p-p
Capacitance @ Frequency
25000pF @ 1kHz
Size
1.38" Dia (35mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
102-1131
CEB35FD29
SEB-35FD29
SEB35FD29
Measuring Methods
1) Resonant frequency / Resonant impedance
2) Static capacitance
Mechanical Characteristics
Item
Solderability
Lead Wire Pull Strength
Vibration
The piezo electric diaphragm should be clamped at a node point (as shown in the following figure) to be free from any
mechanical stress. Measure its resonant frequency and resonant impedance by using a vector impedance analyzer or
equivalent.
When the input frequency is swept within 100 Hz to 5 KHz, the resonant frequency is defined as the frequency where
the impedance shows minimum value. This impedance should be the resonant impedance.
The electrostatic capacitance should be measured at 120 Hz by using an L.C.R. meter (ex. HP4194A(H.P.)) or
impedance mentioned above.
equivalent. The part should be clamped in the same way as the measurement or resonant frequency / resonant
Phone: 800.275.4899
Fax: 503.612.2381
Test Condition
Stripped wires of lead wires are immersed in
rosin for 5 seconds and then immersed in
solder bath of 270 ±5°C for 3 ±0.5 seconds.
The horizontal force of 3.0N (0.306kg) should
be applied to the double lead wire for 30 sec.
The diaphragm should be measured after
applying a vibration amplitude of 1.5 mm with
10 to 55 Hz band of vibration frequency to each
of the 3 perpendicular directions for 2 hours.
Part No: CEB-35FD29
Description: piezo electric diaphragm
www.cui.com
20050 SW 112th Ave.
Evaluation Standard
90% min. of the stripped wires
will be wet with solder.
(Except the edge of the terminal)
No damage or cutting off.
The value of the resonant
frequency should be ±10% of the
initial measurements.
Electrostatic capacitance should
be ±20% compared with the initial
measurement. The resonant
impedance should be 2000Ω
max.
Tualatin, OR 97062
Date: 6/25/2007
Unit: mm
Page No: 2 of 4