9-1393792-3 TE Connectivity, 9-1393792-3 Datasheet - Page 69

no-image

9-1393792-3

Manufacturer Part Number
9-1393792-3
Description
Electromechanical Relay DPDT 3A 5VDC 125Ohm Through Hole
Manufacturer
TE Connectivity
Type
Signal Relayr
Datasheet

Specifications of 9-1393792-3

Contact Arrangement
DPDT
Dc Coil Voltage
5 V
Coil Current
40 mA
Mounting
Through Hole
Features
• Type K Foot Mount - features a steel bracket welded to the bottom of the
• Type G Panel Mount - features .218” (5.54 mm) diameter holes in each
• For agency approval, 60 & 75VA transformers must have one of the
• Multiple voltage combinations are available. Consult factory for availability.
Standard “999” Models Available
For more details about standard models see Part Numbering System table at
beginning of transformer section in this catalog . All 75VA standard models
come with an integral circuit breaker.
Type K
Foot Mount -
Internally
Fused
Type K
Foot Mount -
Integral
Circuit
Breaker
Type G
Panel Mount
Dimensions are shown for
reference purposes only.
Outline Dimensions
Voltage
Color
Length [inches (mm)]
Strip Length [inches (mm)]
Details regarding leads on standard models
laminations for easy mounting.
corner to allow direct mounting to a panel.
following overcurrent protectors in series with the secondary winding:
Internal fuse, integral circuit breaker. Any customer-supplied fusing or
protection must be approved by the factory.
120/208/240/480
Primary V
208/240
120
277
575
.187 DIA
(4.75)
Secondary V
.187 DIA
(4.75)
(19.05)
(19.05)
.750
.750
24
24
24
24
24
0.5 (12.7)
12 (305)
COM
Black
3.562 (90.47)
2.106 (53.49)
2.106 (53.49)
3.562 (90.47)
2.106 (53.49)
Dimensions are in inches over
(millimeters) unless otherwise
specified.
0.5 (12.7)
12 (305)
4000-01J15K999
4000-03J15K999
4000-09J15K999
4000-78J15K999
4000-08J15K999
White
120
75VA
(5.59)
(5.59)
.22
.22
0.5 (12.7)
12 (305)
Red
208
(63.5)
2.50
(63.5)
2.50
Catalog 1308242
Primary Leads
Issued 3-03
“A” and “B” Dimensions for 60VA & 75VA Models
0.5 (12.7)
“A” Dimension [inches (mm)]
“B” Dimension [inches (mm)]
12 (305)
Orange
240
3.00 (76.2)
2.50 (63.5)
3.00 (76.2)
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Specifications
Frequency: 50/60 Hz.
Insulation Class: UL Class B (130°C).
Weight:
* A three digit customer ID suffix will be assigned by the factory.
For Type G Panel Mount, replace K in above part numbers with G.
Specifications and availability
subject to change.
4000
Class II UL 1585 Transformer
60VA -75VA Non-Inherently Energy Limited
Secondary Fusing Required
Wire Leads
Wire Size: All leads are 18 AWG stranded 2/64” (.794 mm) insulation
Partial Listing of Custom Models
120/208/240
208/240/480
Primary V
.218 (5.54)
208/240
380/415
120
240
277
480
575
0.5 (12.7)
12 (305)
Brown
277
(50.8)
.218 DIA
60VA – 35.2 oz. (997 g); 75VA – 38.4 oz. (1087 g).
2.0
File E87824
(1.57)
.062
thickness. Standard parts have 12” (305 mm) total length with
1/2” (12.7 mm) strip.
(5.54)
(1.57)
.062
series
Secondary V
Internally Fused w/ Integral Circuit Breaker Standard Part
Black/Red
0.5 (12.7)
24
24
24
24
24
24
24
24
24
12 (305)
2.475 (62.86)
L15K & J15K
1.00 (25.4)
480
4000-01L15K*
4000-02L15K*
4000-03L15K*
4000-04L15K*
4000-05L15K*
4000-09L15K*
“B” DIM.
SEE TABLE
SEE TABLE
0.5 (12.7)
12 (305)
SEE TABLE
Gray
(46.48)
60VA
575
1.830
(46.48)
(46.48)
1.830
1.830
L15K & J15K
3.25 (82.55)
PRODUCTS UNLIMITED
1.00 (25.4)
“A” DIM.
“A” DIM.
0.5 (12.7)
12 (305)
“A” DIM.
Blue
24
Secondary Leads
4000-01J15K*
4000-02J15K*
4000-03J15K*
4000-04J15K*
4000-05J15K*
4000-09J15K*
4000-13J15K*
4000-51J15K*
4000-78J15K*
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
“B” DIM.
75VA
“B” DIM.
1.125 (28.58)
3.45 (87 .63)
0.5 (12.7)
12 (305)
(21.1)
Yellow
.830
J41K
VAC
209