1571112-1 TE Connectivity, 1571112-1 Datasheet - Page 292

no-image

1571112-1

Manufacturer Part Number
1571112-1
Description
Switch Rocker ON OFF DPST Faston Rocker 16A 250VAC >100000Cycle
Manufacturer
TE Connectivity
Datasheets

Specifications of 1571112-1

Mounting
Panel Mount
Switch Configuration
ON OFF
Pole Throw Configuration
DPST
Maximum Ac Voltage Rating
250 V
Actuator Style
Rocker
Current Rating (max)
16A
Illumination Type
Lamp
Ac Voltage Rating (max)
250VVAC
Mechanical Life
>100000
Contact Material
Silver Tin Oxide
Contact Plating
Silver
Housing Material
N/A/Nylon
Product Height (mm)
37.3mm
Product Depth (mm)
29.3mm
Product Length (mm)
31.5mm
Operating Temp Range
-20C to 85C
Mounting Style
Panel
Terminal Type
Faston
Lead Free Status / Rohs Status
Compliant
Catalog 1308390
Issued 9-04
www.tycoelectronics.com
• Actuation Force (Operating Force): The force required to
• Actuator: A movable part of a switch which causes a change in
• Alternate Action: See Push-Push.
• Angle of Throw: The angle or arc through which an actuator
• Antistatic: An antistatic device will withstand a specified
• Bifurcated Contact: A wiping movable contact consisting of
• Bobbin Contact: A movable contact shaped like a thread bobbin
• Bounce: See Contact Bounce.
• Break-Before-Make (Non-shorting, Break First): On
• Break First: See Break-Before-Make.
• Butt Contact: A contact mechanism in which the movable
• Capacitive Load: A load in which the initial current on making
• Carrying Current: The maximum current that can be passed
• Contact (Contact Area): The metal surfaces that come into
• Contact Block: A switching element which is added singly or in
change the actuator of a switch from one position to the other.
Unit of Measure: Slides - lbs., oz. or grams. Toggles and
pushbuttons - oz. Rotary products-torque.
the electrical configurations of the switch.
Example:
passes during actuation. Typically used to refer to the
movement of toggle or rocker actuators. Unit of Measure:
Degree.
potential without conducting between the actuator and any
conducting element, usually the terminals or bushing. Unit of
Measure: Typical value 15-20 kilovolts DC.
two spring fingers that grip fixed contacts. Typically found in
slide switches. Self-cleaning action. See Wiping Contact.
that rolls along the stationary contacts. Found only in slide
switches.
actuation, the movable contact breaks contact with one fixed
contact before making contact with another fixed contact.
Contrast with make-before-break. Typical of toggle and
pushbutton switches. (BBM)
contact makes contact with the fixed (stationary) contact
without wiping motion between the surfaces. Typical of toggle
and pushbutton switches. See Wiping Contact.
(closing) of the contacts is higher than the steady state current
on breaking (opening) of the contacts, the current is less than
steady state. Current leads voltage in capacitive loads. See
Resistive Load, Inductive Load, Power Factor and Inrush.
through the already closed contacts of a switch. Contrast with
“Contact Rating.”
physical contact to complete an electrical circuit. These
surfaces are found on moveable contacts (see) and terminals
(see).
groups to an operator (see) to make a complete switch.
Plunger
Toggle
Dimensions are in inches
and millimeters unless otherwise
specified. Values in parentheses
or brackets are metric equivalents. to change.
Rocker
Paddle
Index/Matrixes
Glossary
Slider
Shaft
Dimensions are shown for
reference purposes only.
Specifications subject
• Contact Bounce (Bounce): The time during switching in which
• Contact Gap: The distance between a stationary contact and a
• Contact Rating (Switching Rating): The capacity to switch
• Contact Resistance: The total resistance of the switch,
• Cycles: The number of times a switch can be actuated from one
• Detent: A mechanical stop that holds the contacts in a given
• Detent Angle: The angle or arc between detent positions in
• Dielectric Strength (Dielectric Withstanding Voltage, DWV,
• Dielectric Withstanding Voltage: See Dielectric Strength.
• DIP: Dual-in-Line Package refers to a component with two rows
• Double-Break Contacts: A contact mechanism using two sets of
• Dry Circuit (Low Energy, Logic Level): An application in
• DWV: See Dielectric Strength.
• Electrical Life: The number of operations at a given electrical
electrical instability caused by the rebound of the contacts is
observed. Unit of Measure: Millisecond.
moveable contact in the open position.
(connect or interrupt) an electrical load. Unit of Measure: Volts,
amps, load characteristic (resistive, inductive, capacitive, power
factor). Contrast with non-switching rating.
comprised of the contact interface and terminals. Unit of
Measure: Milliohms.
extreme position to the opposite extreme position and back to
the original position.
position after the actuation force is removed or prevents the
changing of contact position at less than a specified actuation
force.
rotary switches. Unit of Measure: Degree.
Leakage Resistance, Breakdown Voltage): The ability of an
insulator to withstand a voltage without arcing across its
surface. Most often applies to insulator between switch
terminals and metal exposed to operator of switch. Unit of
Measure: Volts RMS, Volts AC.
of PC terminals. The terminals are most commonly on a 0.100"
pitch with 0.300" between rows.
contacts to make or break a given circuit. This provides better
power handling capacity and longer switch life. Typical of high
power industrial switches. See Single-Break Contacts.
which power levels do not cause arcing, melting or softening of
contacts. Typically requires gold plated contacts for reliable
switch operation. Typical Definition: 0.4VA max. @ 20 VDC
or peak AC.
load that does not result in a degredation of any electrical or
mechanical parameter beyond the standard set by the applicable
end-of-life criteria. Unit of Measure: Cycles (on-off operations)
(rotations).
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967
M7