2-1393248-6 TE Connectivity, 2-1393248-6 Datasheet

Circuit Breaker Thermal 2Pole 15A 50VAC 4-Pin

2-1393248-6

Manufacturer Part Number
2-1393248-6
Description
Circuit Breaker Thermal 2Pole 15A 50VAC 4-Pin
Manufacturer
TE Connectivity
Type
Thermalr
Datasheets

Specifications of 2-1393248-6

Current Rating
15 A
Voltage Rating
50 Vac
Number Of Poles
2
Actuator Type
Rocker
Mounting Style
Panel
Termination Style
Quick Connect
Lead Free Status / RoHS Status
Compliant
114
Features
• Combines on/off switch and circuit protection in a single unit.
• 2 to 20 amp ratings (<2A types available as special order).
• One or two pole sensing.
• Lighted or non-lighted rocker actuator in various colors.
• Convenient, snap-in mounting.
• Optional auxiliary switch available.
• Trip-free operation.
Time vs. Current Trip Curve @ +25°C
Dimensions are shown for
reference purposes only.
Agency Approvals
W33 series is UL 1077 Recognized as Supplementary Protectors, File
E69543, and CSA Accepted as Supplementary Protectors (Appliance
Component Protectors), File LR15734.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
1000
900
800
700
600
500
400
300
200
100
0
.1
1
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Time In Seconds
10
Issued 3-03 (PDF Rev. 9-05)
Overload
Catalog 1308242
1000%
100%
135%
200%
400%
600%
800%
100
All Models
Mechanical/Environmental Data
Termination: Poles 1&2: .250” (6.35mm) quick connect/solder terminals.
Mounting: Snaps into panel from front.
Actuator: Rocker or lighted rocker.
Shock: 30g tested to IEC 68-2-27 , test Ea.
Vibration: 8g tested to IEC 68-2-6, test Fc.
Switch Endurance Cycling:
Specifications and availability
subject to change.
Electrical Data @ 25°C
Calibration: Breaker will continuously carry 100% of rated load. It may trip
Dielectric Strength: Over 2,000 volts RMS.
Maximum Operating Voltages: 50VDC; 250VAC to 400 Hz.
Interrupt Capacity: 1,000 amps at 50VDC; 250VAC, 60 Hz. and
Resettable Overload Capacity: Ten times rated current.
W33
One- and Two-Pole, Switchable
Thermal Circuit Breaker / Power Switch
With Optional Indicator Lamp
0.25 - 2.2 Sec.
0.20 - 0.6 Sec.
Trip Times
Trip in 1 hour
3.0 - 33 Sec.
0.6 - 10 Sec.
0.34 - 5 Sec.
No Trip
between 101% and 135%, but must trip at 135% within one
hour at +25°C.
series
Opt. Aux. Sw.: .110”(2.79mm) quick connect terminals.
1000
125/250VAC, 400 Hz.
1,500 amps at 125/250VAC, 60 Hz.
To use this chart: Read up from the ambient
temperature to the curve, and across to find a
correction factor. Multiply the breaker rating by the
correction factor to determine the compensated
rating. Calculate the overloads in terms of the
compensated rating to use the published trip curve.
Ambient Compensation Chart
1.40
1.30
1.20
1.10
1.00
0.90
0.80
0.70
0.60
Ambient Temperature In Degrees Centigrade (°C)
50,000 operations at rated load.
1,000 operations at 200% rated load.
–20 –10 0
10 20 30 40 50 60
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
P&B

Related parts for 2-1393248-6

2-1393248-6 Summary of contents

Page 1

... Features • Combines on/off switch and circuit protection in a single unit. • amp ratings (<2A types available as special order). • One or two pole sensing. • Lighted or non-lighted rocker actuator in various colors. • Convenient, snap-in mounting. • Optional auxiliary switch available. • Trip-free operation. ...

Page 2

... W = Circuit breaker 2. Series Number Two pole, rocker actuated 3. Circuit Function Pole 1 – Switch only; Pole 2 – Series trip overload sensing Poles 1 & 2 – Series trip overload sensing Same as S with auxiliary switch on pole Same as T with auxiliary switch on pole Pole switching. ...