R4E310-AE13-16 EBM-Papst Industries Inc, R4E310-AE13-16 Datasheet - Page 2

IMPELLER MTRZD 318X132MM 115VAC

R4E310-AE13-16

Manufacturer Part Number
R4E310-AE13-16
Description
IMPELLER MTRZD 318X132MM 115VAC
Manufacturer
EBM-Papst Industries Inc
Series
R4E310r
Type
Roundr
Datasheets

Specifications of R4E310-AE13-16

Bearing Type
Ball
Voltage Rating
115VAC
Size / Dimension
Round - 318mm Dia x 132mm W
Termination
2 Wire Leads
Fan Type
Motorized Impellers
Weight
8 lbs (3.6kg)
Power (watts)
155W
Noise
68 dB(A)
Air Flow
1265 CFM (35.82³/min)
External Diameter
310mm
Current Type
AC
Supply Voltage
115VAC
Flow Rate
1265CFM
Noise Rating
68dBA
Power Connection Type
Lead Wires
Diameter
310mm
Power Rating
155W
Material, Impeller
Aluminum
Noise Level
68 dBA
Power, Rating
155 W
Voltage, Rating
115 VAC
Cable Exit
Variable. Direction of Rotation is CW as Seen from Intake Side
Recommended Inlet Ring
31051-2-4013 (Sold Separately)
Flow Rate - Imperial
1265CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rpm
-
Termination Style
-
Static Pressure
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R4E310AE1316
1.5 Safety and protective functions
1.6 Electromagnetic radiation
Interference from electromagnetic radiation possible, e.g. in conjunction with open
and closed-loop control devices.
If unacceptable emission intensities occur when the fan is installed, suitable shield-
ing measures must be taken before the device is commissioned.
1.7 Mechanical movement
1.8 Emission
2/5
CAUTION
The motor restarts automatically when operating voltage
is applied, e.g. after a power failure.
Danger of injury
➜ Keep out of the danger zone of the device.
➜ When working on the device, switch off the mains supply voltage
➜ Wait until the device stops.
➜ If thermal overload protectors are led through, insert these into
DANGER
Missing safety device and non-functioning protective features
If there is no safety device, you could be seriously injured, for exam-
ple by reaching into the running device with your hands.
➜ Operate the device only with a fixed guard and guard grille. The
➜ The device is a built-in component that has no function on its
➜ Shut down the device immediately if you detect a missing or inef-
NOTE
Electrical or electromagnetic interferences after integrating
the device in installations on the customer's side.
➜ Verify that the entire setup is EMC compliant.
DANGER
Rotating device
Body parts that come into contact with the rotor and impeller can
be injured.
➜ Secure the unit to prevent contact. Before working on the installa-
WARNING
Rotating device
Long hair, loose items of clothing and jewellery could become
entangled and pulled into the device. You could be injured.
➜ Do not wear any loose clothing or jewellery while working
➜ Protect long hair with a hood.
WARNING
Depending on the installation and operating conditions, a sound
pressure level greater than 70 dB(A) can arise.
Danger of noise-induced hearing loss
➜ Take appropriate technical safety measures.
➜ Safeguard the operating personnel with appropriate protection
and secure the latter from being switched on again.
guard must withstand the kinetic energy of a fan blade.
fective protective feature.
tion/machine, wait until all parts have come to a standstill.
the control circuit so that the cooled off motor does not switch on
independently after a fault.
own. As the operator, you are responsible for ensuring that the
device is adequately secured.
on moving parts.
measures, e.g. ear protectors.
1.9 Hot surface
1.10 Transport
1.11Storage
Store the device in a dry and weatherproof manner in the original packing in a
clean environment.
Protect the device from environmental impacts and dirt until the final installation.
We recommend storing the device for a maximum of one year.
Maintain the storage temperature.
1.12 Disposal
When disposing of the device, please comply with all relevant requirements and
regulations applicable in your country.
CAUTION
High temperature at the motor housing
Danger of burn injuries
➜ Ensure that sufficient protection against accidental contact is
CAUTION
Transport of fan
➜ Transport the fan in its original packaging only.
➜ Secure the fan so that it does not slip, for example using a lash-
provided.
ing strap.

Related parts for R4E310-AE13-16