PKY4716PI Ericsson Power Modules, PKY4716PI Datasheet
PKY4716PI
Specifications of PKY4716PI
Available stocks
Related parts for PKY4716PI
PKY4716PI Summary of contents
Page 1
... PKY 4616 PI ......................................... 5 PKY 4716 PI ......................................... 9 ........................................................... 13 ........................................................... 14 ........................................................... 16 ........................................................... 17 ........................................................... 18 ........................................................... 19 ........................................................... 19 ........................................................... 20 Technical Specifi cation Rev Reference Rev Reference EN/LZT 146 380 R2A Oct 2008 C C © Ericsson Power Modules AB Design for Environment Meets requirements in high- temperature lead-free soldering processes. 1 (3) 1 (1) ...
Page 2
... Warranty period and conditions are defined in Ericsson Power Modules General Terms and Conditions of Sale. Limitation of Liability Ericsson Power Modules does not make any other warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a person’ ...
Page 3
... Approved PKY 4000 PI series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output A/700 W Safety Specification General information Ericsson Power Modules DC/DC converters and DC/DC regulators are designed in accordance with safety Safety of Information standards IEC/EN/UL60950, Technology Equipment . IEC/EN/UL60950 contains requirements to prevent injury or damage due to the following hazards: • ...
Page 4
... PRODUCT SPECIFICATION No. 2/1301-BMR 638/1 Uen Checked Date ECHWANG 2008-10-9 Positive logic option Negative logic option Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules AB min typ max -40 +100 -55 +125 -0.5 +100 1500 100 -100 +12 ...
Page 5
... V, 0-100 % max +25° 0-100 % max I O max 36- Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules AB PKY 4616 PI min typ max 36 75 32.1 33 34.5 33.3 35 35.5 35.2 0 600 95 93.5 94.5 95 93.5 94,5 34.9 41 ...
Page 6
... Dissipated power vs. load current and input voltage at = +25° +25°C P1 Current Limit Characteristics [V] 35 7.0 0 utput voltage vs. load current at I Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules [A] > max +25° (10) 6 PKY 4616 [ ...
Page 7
... Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules AB PKY 4616 PI at: Top trace: output voltage 10 V/div. I Bottom trace: input voltage 20 V/div. Time scale: 50 ms/div. Trace: output voltage 0.5 V/div. Time scale: 0.2 ms/div. ...
Page 8
... Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section 100 [°C] Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules AB 0.5 1.0 1.5 2.0 2.5 3.0 [m/ (10) ...
Page 9
... V, 0-100 % max +25° 0-100 % max I O max 36- Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules AB PKY 4716 PI min typ max 36 75 32.1 33 34.5 33.3 35 35.5 35.2 0 700 94.0 92.5 94.1 94.3 93 94.2 44 ...
Page 10
... P1 Current Limit Characteristics [V] 35 7.0 0 [A] Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules Dissipated power vs. load current and input voltage +25° utput voltage vs. load current at I > max (10) 10 PKY 4716 PI ...
Page 11
... Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules AB PKY 4716 PI at: Top trace: output voltage 10 V/div. I Bottom trace: input voltage 20 V/div. Time scale: 50 ms/div. Top trace: output voltage (1 V/div.). Bottom trace: load current (10 A/div.). ...
Page 12
... Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section 100 [°C] Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules AB 0.5 1.0 1.5 2.0 2.5 3.0[m/ (10) ...
Page 13
... See Design Note 022 for detailed information. C1, C2 5µF (100V, ceramic) C4 10nF (2000V, ceramic 2x470µF (100V, electrolytic) L1 200µH common mode inductor Output ripple and noise test setup Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules AB 1 (6) 13 ...
Page 14
... To decrease the output voltage, the resistor should be connected between the V Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules AB ) adj pin and +Sense pin. The resistor value of the adj pin and –Sense pin. adj ...
Page 15
... overloaded, the main converter will be switched off. An example of a 5V/45mA power supply driven by the auxiliary output voltage is given in the figure below. Thermal Consideration Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules AB 3 (6) 15 ...
Page 16
... P1 safety margins, proper operation and high reliability ot the product. Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules AB Temp. limit 100º C 120º C 125º C 120º C 120º (6) ...
Page 17
... Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 C © Ericsson Power Modules AB Function Remote on/off “plus” input Remote on/off “minus” input Positive input Negative input Auxiliary power supply output Power Good output N/A ...
Page 18
... PKY 4000 PI series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output A/700 W Mechanical Information PRODUCT SPEC. MECHANICAL No. 4/1301-BMR 638 Uen Checked Date See § 1 2008-10-10 Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 B © Ericsson Power Modules AB 1 (2) 18 ...
Page 19
... Box capacity 5 products (1 full tray/box) Tray weight 55 g empty, 880 g full tray PROD. SPECIFICATION MECHANICAL No. 5/1301-BMR 638 Checked Date See §1 2007-06-27 12 Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 A © Ericsson Power Modules AB 1 (3) 19 ...
Page 20
... Preconditioning Temperature, SnPb Eutectic Temperature, Pb-free Frequency Spectral density Duration Technical Specifi cation Rev Reference EN/LZT 146 380 R2A Oct 2008 A © Ericsson Power Modules AB -40 to +100°C 1000 15 min/0-1 min -45° +85° 1000 hours +125°C 1000 h Class 2, 2000 V Class 3, 200 V +55° ...