8-1611454-0 TE Connectivity, 8-1611454-0 Datasheet
8-1611454-0
Specifications of 8-1611454-0
Related parts for 8-1611454-0
8-1611454-0 Summary of contents
Page 1
... Wire Leads & Screws Foot or Panel Plate 205 206 Transformers PRODUCTS PRODUCTS UNLIMITED UNLIMITED 4000 4700 Class II UL1585 UL506 Transformer Transformer Non-Inherently Energy Limited Non-Fused Secondary Fusing Required (Opt. integral fuse or breaker) 60 & 75VA 60, 100 & 150VA Quick Connect Wire Leads ...
Page 2
... Wire Leads, Class II ................. 207 4000 ................... 40-50VA, QC Terminals, Class II ............. 208 4000 ................... 60-75VA, Wire Leads, Class II ................. 209 4000 ................... 60-75VA, QC Terminals, Class II ............. 210 4700 ................... 60-150VA, Wire Leads or QC, UL 508 .... 211 57 ....................... Transformer Relay for HVAC ................... 212 Transformers........ Custom Capabilities........................................203 Transformers........ Questions and Answers..................................202 ...
Page 3
... Typical USA supply voltages are 120, 208, 240, 277, 480 (and 575 in Canada). Common International voltages include 110, 220, 380, and 415. What is an Isolation Transformer? An isolation transformer is a transformer whose primary and secondary windings are separate for the purpose of isolating the circuit from the supply source ...
Page 4
... Our electrical and mechanical design groups are ready to work with you on your specific product needs. Dimensions are shown for Dimensions are in inches over reference purposes only. (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 DFM Method • DPPM level <100 • 1 Week lead time • 1 Universal part number • ...
Page 5
... All leads are 18 AWG stranded 2/64” (.794 mm) insulation thickness. Standard parts have 12” (305 mm) total length with 1/2” (12.7 mm) strip. 50/60 Hz. UL Class B (130°C). 5VA – 10.56 oz. (300 g); 10VA – 10.88 oz. (308 g); 20VA – 14.24 oz. (404 g); 30VA – 19.2 oz. (544 g). 5VA 10VA 20VA ...
Page 6
... Standard male quick connects are .250” x .032” (6.35 x .81 mm). Other available quick connects include .187” x .032” (4.75 x .81 mm) and .187” x .020” (4.75 x .51 mm). 50/60 Hz. UL Class B (130°C). 10VA – 10.9 oz. (308 g); 20VA – 14.1 oz. (399 g); 30VA – 18.6 oz. (525 g). Primary V Secondary V 10VA ...
Page 7
... PRODUCTS UNLIMITED series File E87824 All leads are 18 AWG stranded 2/64” (.794 mm) insulation thickness. Standard parts have 12” (305 mm) total length with 1/2” (12.7 mm) strip. 50/60 Hz. UL Class B (130°C). 20VA – 19.2 oz. (544 g); 40VA – 32 oz. (906 g). ...
Page 8
... It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. All leads are 18 AWG stranded 2/64” (.794 mm) insulation thickness. Standard parts have 12” (305 mm) total length with 1/2” (12.7 mm) strip. ...
Page 9
... Standard male quick connects are .250” x .032” (6.35 x .81 mm). Other available quick connects include .187” x .032” (4.75 x .81 mm) and .187” x .020” (4.75 x .51 mm). 50/60 Hz. UL Class B (130°C). 40VA – 22.4 oz. (636 g); 50VA – 35.2 oz. (999 g). ...
Page 10
... Type K Foot Mount - features a steel bracket welded to the bottom of the laminations for easy mounting. • Type G Panel Mount - features .218” (5.54 mm) diameter holes in each corner to allow direct mounting to a panel. • For agency approval, 60 & 75VA transformers must have one of the following overcurrent protectors in series with the secondary winding: Internal fuse, integral circuit breaker ...
Page 11
... Standard male quick connects are .250” x .032” (6.35 x .81 mm). Other available quick connects include .187” x .032” (4.75 x .81 mm) and .187” x .020” (4.75 x .51 mm). 50/60 Hz. UL Class B (130°C). 60VA – 35.2 oz. (997 g); 75VA – 38.4 oz. (1087 g). ...
Page 12
... Standard male quick connects are .250” x .032” (6.35 x .81 mm). Other available quick connects include .187” x .032” (4.75 x .81 mm) and .187” x .020” (4.75 x .51 mm). 50/60 Hz. UL Class B (130°C). 60VA – 36.8 oz. (1042 g); 100VA – 80 oz. (2270 g); 150VA – 83.2 oz. (2356 g). Primary V 100VA 120 – ...
Page 13
... Cover mounts on conventional 4” square box. • All leads terminate in the box. • Leads are 8” (203.2 mm) long with 1/2” (12.7mm ) stripped) • Standard transformer is 40VA Class II Energy Limited. Other transformers are available. • Five secondary terminations (two are hot) for thermostat connection and #6-32 screw termination is standard. Quick connects are optional. • ...