H3DK-G AC/DC24-240 Omron, H3DK-G AC/DC24-240 Datasheet - Page 4

no-image

H3DK-G AC/DC24-240

Manufacturer Part Number
H3DK-G AC/DC24-240
Description
TIMER, STAR DELTA DELAY, 24-240AC/DC
Manufacturer
Omron
Datasheet

Specifications of H3DK-G AC/DC24-240

Contact Configuration
Star - SPDT. Delta - SPDT
Delay Time Range
1s To 120s
Relay Mounting
DIN Rail
Svhc
No SVHC (15-Dec-2010)
Adjustment Type
Screwdriver Slot
Contact Current Ac Max
5A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4
H3DK-M/H3DK-S
■ Characteristics
■ Applicable standards
■ I/O
* With the H3DK-M@, if the voltage exceeds 26.4 VAC/DC in mode C, D, or G, the OFF trigger signal char-
* If the INST/TIME switch on the front of the Timer is set to INST on the H3DK-M2/-S2, relay R2 will
Accuracy of operating
time
Setting error
Minimum input signal
width
Influence of voltage
Influence of tempera-
ture
Insulation resistance
Dielectric strength
Impulse withstand volt-
age
Noise immunity
Static immunity
Vibration
resistance
Shock re-
sistance
Life ex-
pectancy
Degree of protection
Weight
Safety standards
EMC
Item
acteristics are as follows:
Accuracy of operating time: ±1% ±50 ms max.
Setting error: ±10%
Minimum input signal width: 100 ms
operate as instantaneous contacts and will turn ON/OFF in synchronization with the power supply.
Output
Input
Destruction 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions
Malfunction 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction 1,000 m/s
Malfunction 100 m/s
Mechanical 10 million operations min. (under no load at 1,800 operations/h)
Electrical
Control
output
Start
Model
cURus: UL 508/CSA C22.2 No. 14
EN 50274: Finger protection, back-of-hand proof
EN 61812-1: Pollution degree 2, Overvoltage category III
CCC: Pollution degree 2, Overvoltage category II, section DB14048.5-2008 part 5-1
LR: Test Specification No. 1-2002 Category ENV 1.2
(EMI)
Radiated Emissions:
Emission AC Mains:
Harmonic Current:
Voltage Fluctuations and Flicker: EN61000-3-3
(EMS)
ESD Immunity:
Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves):
Burst Immunity:
Surge Immunity:
+100 ms
−50 ms
Functions to start timing.
The output is turned ON/OFF according to the operating mode when the value
that is set on the dial is reached. *
±1% of FS max. (±1% ±10 ms max. at 1.2-s range)*
±10% of FS ±0.05 s max.*
50 ms* (start input)
±0.5% of FS max. (±0.5% ±10 ms max. at 1.2-s range)
±2% of FS max. (±2% ±10 ms max. at 1.2-s range)
Between current-carrying metal parts and exposed non-current-carrying metal
parts: 2,000 VAC 50/60 Hz for 1 min.
Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for
1 min.
Between contacts not located next to each other: 1,000 VAC 50/60 Hz for
1 min.
24 to 240 VAC/VDC: 3 kV between power terminals, 4.5 kV between current-
carrying metal parts and exposed non-current-carrying metal parts
12 VDC: 1 kV between power terminals, 1.5 kV between current-carrying metal
parts and exposed non-current-carrying metal parts
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs,
Malfunction: 4 kV, Destruction: 8 kV
IP30 (Terminal block: IP20)
Approx. 120 g
100 MΩ min. at 500 VDC
1-ns rise): ±1.5 kV
100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)
max.
2
3 times each in 6 directions
2
H3DK-M1/-M2
3 times each in 6 directions
EN61812-1
EN 55011 class B
EN 55011 class B
EN 61000-3-2
EN61812-1
EN 61000-4-2: 6 kV contact discharge,
EN 61000-4-3: 10 V/m (80 MHz to 1 GHz)
EN 61000-4-4: 2 kV power line,
EN 61000-4-5: 2 kV common mode,
There is no start input.
8 kV air discharge
1 kV I/O signal line
1 kV differential mode
H3DK-S1/-S2
● Installation Pitch and Output
The relation between the installation pitch
and the load current is shown in the follow-
ing graph. (Except for the H3DK-GE)
If Timer is used under load conditions that
exceed the specified values, the tempera-
ture inside the Timer will increase, reducing
the life expectancy of internal parts.
Testing Method
DIN Track
Tested Timer: H3DK-M/-S
Applied voltage: 240 VAC
Installation pitch: 0, 5, 10, and 50 mm
Switching Capacity (Reference Val-
ues)
80
70
60
50
40
30
20
10
timer
0
Test
1
Timer installation pitch: d
1
timer
Test
2
2
timer
Test
3
3
timer
Test
4
4
Load current (A)
timer
Test
5
5
d = 50 mm
d = 10 mm
d = 5 mm
d=0 A
6

Related parts for H3DK-G AC/DC24-240