ACV13012 PANASONIC EW, ACV13012 Datasheet - Page 5

MICRO AUTOMOTIVE RELAY, SPDT, 12VDC, 20A

ACV13012

Manufacturer Part Number
ACV13012
Description
MICRO AUTOMOTIVE RELAY, SPDT, 12VDC, 20A
Manufacturer
PANASONIC EW
Datasheet

Specifications of ACV13012

Coil Voltage Vdc Nom
12V
Contact Current Max
20A
Contact Voltage Dc Nom
14V
Coil Resistance
180ohm
Contact Configuration
SPDT
Relay Mounting
PCB
External Height
16.7mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
CV (ACV)
4-(3). Electrical life test (Motor load)
Sample: ACV12212, 3pcs.
Load: inrush: 80A/steady: 18A,
radiator fan actual load (motor free)
Switching frequency: (ON : OFF = 2s : 6s)
Ambient temperature: Room temperature
Circuit
Load current waveform
Inrush current: 80A, steady current: 18A
Cautions regarding the protection element
1. Part numbers without protection
elements
• 12 V models
When connecting a coil surge protection
circuit to these relays, we recommend a
Zener diode with a Zener voltage of 24 V
or higher, or a resistor (680 to 1,000 ).
When a diode is connected to the coil in
parallel, the release time will slow down
and working life may shorten. Before use,
please check the circuit and verify that
the diode is not connected in parallel to
the coil drive circuit.
2. Part numbers with diodes
These relays use a diode in the coil surge
protection element. Therefore, the
release time is slower and the working life
might be shorter compared to part
numbers without protection elements and
part numbers with resistors.
Be sure to use only after evaluating under
actual load conditions.
For Cautions for Use, see Relay Technical Information.
13.5VDC
Up: Coil
voltage
waveform
10V
500ms
Down: Load
current
waveform
20A
M
500ms
M
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Change of pick-up and drop-out voltage
3. Part numbers with resistors
This part number employs a resistor in
the coil surge protection circuit; therefore,
an external surge protection element is
not required. In particular, when a diode
is connected in parallel with a coil, the
revert time becomes slower which could
adversely affect working life. Please
check the circuit and make sure that a
diode is not connected in parallel with the
coil drive circuit.
10
9
8
7
6
5
4
3
2
1
0
0
Drop-out voltage
Pick-up voltage
No. of operations,
10
4
20
Max.
Min.
Max.
Min.
X
X
Change of contact resistance
30
25
20
15
10
5
0
0
No. of operations,
10
4
20
Max.
X
Min.