B84113H0000B116 EPCOS Inc, B84113H0000B116 Datasheet

FILTER LINE 250VAC 16A PANEL

B84113H0000B116

Manufacturer Part Number
B84113H0000B116
Description
FILTER LINE 250VAC 16A PANEL
Manufacturer
EPCOS Inc
Datasheet

Specifications of B84113H0000B116

Filter Type
Power Line
Voltage - Rated
250V
Current
16A
Mounting Type
Chassis Mount
Termination Style
Fast-On
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Inductance
-
Other names
495-2809
© EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures
hereto and the information contained therein without EPCOS’ prior express consent is prohibited.
2−line filters
SIFI−H for very high insertion loss
250 V DC/AC, 50/60 Hz, 3 ... 36 A
Series/Type:
Date:
Version:
2008−08−11
05
B84113H0000*

Related parts for B84113H0000B116

B84113H0000B116 Summary of contents

Page 1

... SIFI−H for very high insertion loss 250 V DC/AC, 50/60 Hz, 3 ... 36 A Series/Type: B84113H0000* Date: 2008−08−11 Version: 05 © EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS’ prior express consent is prohibited. ...

Page 2

... SIFI H for very high insertion loss Construction S 2 line filter S Metal case S Polyurethane potting ( Features S Easy to install S Compact design S Cost optimized construction S Medical version with low leakage current S ENEC10, UL and cUL approval c us Applications S Switched mode power supplies for ...

Page 3

... SIFI H for very high insertion loss Typical circuit diagram of B84113H0000B* and B84113H0000G* LINE Technical data and measuring conditions of B84113H0000B* and B84113H0000G* Rated voltage Rated frequency Test voltage line to line for 2 s Test voltage line to case for 2 s Leakage current ...

Page 4

... SIFI H for very high insertion loss Typical circuit diagram of B84113H0000M* (for medical applications) LINE Technical data and measuring conditions of B84113H0000M* Rated voltage Rated frequency Test voltage line to line for 2 s Test voltage line to case for 2 s Leakage current Rated temperature ...

Page 5

... Please read and Cautions and warnings and Important notes at the end of this document. I Case Approx. Ordering code leak style weight 250 B84113H0000B030 1 260 B84113H0000B060 2 420 B84113H0000B110 2 440 B84113H0000B116 3 860 B84113H0000G120 3 870 B84113H0000G125 3 870 B84113H0000G136 I Case Approx. Ordering code leak style weight µA g < 250 B84113H0000M030 < ...

Page 6

... SIFI H for very high insertion loss Dimensional drawing (case style 1) B84113H0000B030...B84113H0000B060 B84113H0000M030...B84113H0000M060 Please read and Cautions and warnings and Important notes at the end of this document. Page B84113H0000* B84143-H0000-*-05-7659 ...

Page 7

... SIFI H for very high insertion loss Dimensional drawing (case style 2) B84113H0000B110...B84113H0000B116 B84113H0000M110...B84113H0000M116 Please read and Cautions and warnings and Important notes at the end of this document. Page B84113H0000* B84143-H0000-*-05-7659 ...

Page 8

... SIFI H for very high insertion loss Dimensional drawing (case style 3) B84113H0000G120...B84113H0000G136 B84113H0000M120...B84113H0000M136 Please read and Cautions and warnings and Important notes at the end of this document. Page B84113H0000* B84143-H0000-*-05-7659 ...

Page 9

... Insertion loss (typical values unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84113H0000B030 100 B84113H0000B110 100 Please read and Cautions and warnings and Important notes at the end of this document. B84113H0000B060 100 B84113H0000B116 100 Page B84113H0000 B84143-H0000-*-05-7659 ...

Page 10

... SIFI H for very high insertion loss Insertion loss (typical values unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84113H0000B120 100 B84113H0000B136 100 Please read and Cautions and warnings and Important notes at the end of this document. ...

Page 11

... SIFI H for very high insertion loss Insertion loss (typical values unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84113H0000M030 100 B84113H0000M110 100 Please read and Cautions and warnings and Important notes at the end of this document. ...

Page 12

... SIFI H for very high insertion loss Insertion loss (typical values unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84113H0000M120 100 B84113H0000M136 100 Please read and Cautions and warnings and Important notes at the end of this document. ...

Page 13

... SIFI H for very high insertion loss Caution and warnings S Please note the advices in our data book “EMC Filters” (latest edition); attention should be paid to the chapter “General safety notes” shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance ...

Page 14

... SIFI H for very high insertion loss Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. ...

Related keywords