CSNR151 Honeywell, CSNR151 Datasheet - Page 2

Board Mount Current Sensors +/-200 A +/-0.5 % Closed Loop Linear

CSNR151

Manufacturer Part Number
CSNR151
Description
Board Mount Current Sensors +/-200 A +/-0.5 % Closed Loop Linear
Manufacturer
Honeywell
Type
Closed Loop Linearr
Datasheets

Specifications of CSNR151

Current Rating
+/- 200 A
Supply Voltage
+/- 12 VDC to +/- 15 VDC
Response Time
< 0.5 us
Operating Temperature
- 40 C to + 85 C
Accuracy
+/- 0.5 %
Body Style
Rectangular
Brand/series
CSN
Current, Switching
62.5 mA
Function
Current
Mounting Type
PCB
Output
Current
Primary Type
Current
Range, Measurement
200 A
Technology
Hall Effect
Termination
Solder
Voltage, Supply
15 VDC
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CSNR151-004
Quantity:
387
Solid State Sensors
Closed Loop Current Sensors
FEATURES
60
Current sensing up to 1200 amps
Measures AC, DC and impulse
currents
Lowest cost/performance ratio
Rapid response, no overshoot
High overload capacity
High level of electrical isolation
between primary and secondary
circuits
Small size and weight
Honeywell Sensing and Control 1-800-537-6945 USA
CLOSED LOOP SENSORS
Closed loop current sensors measure
AC, DC and impulse currents over 0-25,
0-50, 0-100, 0-600 and 0-1200 Amp rang-
es. The CSN Series is based on the princi-
ples of the Hall effect and the null balance
or zero magnetic flux method (feedback
system). The magnetic flux in the sensor
core is constantly controlled at zero. The
amount of current required to balance
zero flux is the measure of the primary
current flowing through the conductor,
multiplied by the ratio of the primary to
secondary windings. This closed loop
current is the output from the device and
presents an image of the primary current
reduced by the number of secondary
turns at any time. This current can be
expressed as a voltage by passing it
through a resistor.
1-815-235-6847 International 1-800-737-3360 Canada
CATALOG NUMBER SYSTEM
PLEASE NOTE: This matrix is intended
only to aid you in identifying sensor cata-
log listings. It is not all-inclusive, and must
not be used to form new listings.
Example: CSNA111
CSN Closed Loop Current Sensor
Current Range (Peak/RMS nom.)
A
B
C
D
E
F
J
K
L
M
P
R
T
Supply Voltage
1
2
3
4
5
6
Coil Characteristics
1 1:1000 turns/90
2 1:2000 turns/160
3 1:2000 turns/130
4 1:1000 turns/50
5 1:1000 turns/110
6 1:1000 turns/30
7 1:2000 turns/80
8 1:2000 turns/25
9 1:5000 turns/50
Housing Material
1 Polycarbonate/ABS blend
PDFINFO
p a g e - 0 6 0
70 A/50 A rms nom.
100 A/50 A rms nom.
90 A/50 A rms nom.
22 A/15 A rms nom.
36 A/25 A rms nom.
150 A/100 A rms nom.
600 A/300 A rms nom.
1200 A/500 A rms nom.
600 A/300 A rms nom.
1200 A/500 A rms nom.
90 A/50 A rms nom.
200 A/125 A rms nom.
150 A/50 A rms nom.
15 V
13 V
5 V
12 V to 18 V
15 V to 24 V
12 V to 15 V
@ 70 C
@ 70 C
@ 70 C
@ 70 C
@ 70 C
@ 85 C
@ 70 C
@ 70 C
@ 70 C
CSN Series