HIH-5031-001S Honeywell, HIH-5031-001S Datasheet

no-image

HIH-5031-001S

Manufacturer Part Number
HIH-5031-001S
Description
Board Mount Humidity Sensors HyCal Sensing Produc 3600 Series CMOS Sen
Manufacturer
Honeywell
Datasheets

Specifications of HIH-5031-001S

Rh Range
0 % to 100 %
Rh Accuracy
+/- 3 %
Output Type
Analog
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Supply Current
200 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Body Style
Rectangular
Current, Switching
500 μA
Function
Humidity
Mounting Type
Surface Mount
Primary Type
Humidity
Range, Measurement
0 to 100 % RH
Voltage, Supply
2.7 to 5.5 VDC
Lead Free Status / RoHS Status
Supplier Unconfirmed
Installation Instructions for the
HIH-5030/5031 Series Humidity Sensors
SOLDERING AND ASSEMBLY
Sensing and Control
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
• The sensor’s housing does not provide electrical safety
Failure to comply with these instructions could result in
death or serious injury.
CAUTION
IMPROPER HANDLING
• Do not remove the sensor from its original protective
• Do not touch the sensor surface. Use latex finger cots.
• Do not allow objects to enter the cavity of the sensor
Failure to comply with these instructions may result in
product damage.
NOTICE
• For HIH-5030 only: Under condensing conditions where
• Shade the sensor from direct light. Intense direct light
• At the end of its working life, dispose the sensor in
CAUTION
IMPROPER CLEANING
• Insert and solder the sensor after the PCB cleaning
Failure to comply with these instructions may result in
product damage.
process.
enough liquid water forms on the sensor to create a
parasitic leakage path, the HIH-5030 Humidity Sensor
produces an erroneous reading of 0% humidity. If this
erroneous reading is assumed to be correct by your
control function, excess humidity is likely to be introduced
into the system. Once the liquid water evaporates from
the sensor and the environment returns to a non-
condensing state, the device returns to normal
functionality.
can flood junctions in the CMOS (Complementary Metal
Oxide Semiconductor) device and drive the output signal
to the minimum. This does not harm the sensor or affect
calibration. Proper operation resumes shortly after the
direct light is removed. Ambient scattered light normally
does not affect performance.
accordance with Directive 2002/96/EC (WEEE).
stop devices or in any other application where failure of
the product could result in personal injury.
isolation. Mount the sensor in a location where it cannot
be touched, or where a surrounding barrier prevents
human contact.
packaging until it is ready to be installed.
Handle the sensor by its package edges or leads.
element.
WARNING
PROTECTIVE TAPE REMOVAL
1.
2.
3.
Figure 1. Protective Tape Removal
SOLDERING
Hand soldering is acceptable. If reflow soldering is required,
use a no-clean flux. Limit the contact of the flux to the leads
only. Reflow soldering profile is specified by J-STD-020B for a
small package with a peak temperature of 250
MOISTURE SEALING THE LEADS
If, in the presence of intermittent moisture or other
contaminants, there is the possibility of galvanic paths between
the leads, moisture seal the leads and exposed pads.
CAUTION
IMPROPER SENSOR POSITIONING
• Position the sensor so that its face is exposed to the
Failure to comply with these instructions may result in
product damage.
CAUTION
IMPROPER SOLDERING
• For better product reliability, the HIH-5030/5031 Series is
• After soldering, remove the protective tape as shown
Failure to comply with these instructions may result in
product damage.
atmosphere being monitored.
factory-shipped with a protective tape on the cover
(sensing face). This tape must remain in place during
soldering.
below to activate the sensor.
Use proper ESD protection.
Using covered fingers or tweezers to ensure that no
foreign debris falls into the filter, sensor cover or die, grip
the overhanging front edge of the protective tape and peel
it back from the top surface of the sensor.
Ensure the complete rectangle of protective tape is
removed.
50038351
ISSUE 1
o
C [482
o
F].

Related parts for HIH-5031-001S

HIH-5031-001S Summary of contents

Page 1

... Failure to comply with these instructions may result in product damage. CAUTION IMPROPER SOLDERING • For better product reliability, the HIH-5030/5031 Series is factory-shipped with a protective tape on the cover (sensing face). This tape must remain in place during soldering. • After soldering, remove the protective tape as shown below to activate the sensor ...

Page 2

... Non-condensing environment. When liquid water falls on the humidity sensor die, output goes to a low rail condition indicating no humidity. 4. Total accuracy including interchangeability is ±3 %RH. Figure 2. Operating Environment (Non-condensing environment for HIH-5030 catalog listings only.) 2 Honeywell • Sensing and Control Minimum Typical Maximum -7 – ...

Page 3

... HIH-5030/5031 Series Figure 3. Storage Environment (Non-condensing environment for HIH-5030 catalog listings only.) Figure 4. HIH-5030 Mounting Dimensions (For reference only. mm/[in]) Figure 5. HIH-5031 Mounting Dimensions (For reference only. mm/[in]) 50038351 Issue 1 Honeywell • Sensing and Control 3 ...

Page 4

... HIH-5030/5031 Series Figure 6. Tape and Reel Dimensions (For reference only. mm/[in]) WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details ...

Related keywords