Manufacturer Part Number
MLH010BGG01B
Description
Industrial Pressure Sensors SST PRESSURE TRANSDUCERS-ATF
Manufacturer
Honeywell
Type
Gager
Datasheet

Specifications of MLH010BGG01B

Pressure Range
0 to 10bar
Overload Pressure (max)
30bar
Mounting
Stud
Pin Count
3
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (min)
9.5V
Operating Supply Voltage (max)
30V
Operating Pressure
0 bar to 10 bar
Pressure Type
Gauge
Accuracy
+/- 0.5 %
Output Type
Amplified
Mounting Style
Stud
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
9.5 V to 30 V
Supply Current
4 mA to 20 mA
Output Voltage
9.5 V to 30 V
Port Size
1/4 in - 18 NPT
Pressure Port
N
Sensor Type
Sensors
Lead Free Status / RoHS Status
Supplier Unconfirmed
Table 4. Performance Specifications (At 25 C [77 F] and at rated excitation unless otherwise specified.)
Notes:
1.
2.
Figure 2. Operating and Temperature Compensated Area
for All Regulated Output Options
Figure 4. Mounting Dimensions (For reference only. mm/(in).)
Parameter
Response time
Accuracy
Total error band
Note:
The dashed line indicates the operating and temperature
compensated area with a 24 V supply.
>100 psi
<100 psi
Gage:
Seal gage:
Seal gage without L, M, P termination:
Seal gage with L, M, P termination:
<300 psig
>300 psig
>300 psis
100 psis to 299 psis (-40 °C to 85 °C [-40 °F to 185 °F])
100 psis to 299 psis (>85 °C to 125 °C [>185 °F to 257 °F])
>300 psis (-40 °C to 125 °C [-40 °F to 257 °F])
100 psis to 299 psis (-40 °C to 65 °C [-40 °F to 149 °F])
100 psis to 299 psis (>65 °C to 125 °C [>149 °F to 257 °F])
>300 psis (-40 °C to 65 °C [-40 °F to 149 °F])
>300 psis (>65 °C to 125 °C [>149 °F to 257 °F])
Includes pressure non-linearity (BFSL), pressure hysteresis and non-repeatability. Thermal errors are not included.
Includes zero error, span error, thermal effect on zero, thermal effect on span, thermal hysteresis, pressure-non-linearity,
pressure hysteresis and non-repeatability.
116
125
124
123
120
119
118
117
122
121
6
1
:
8
2
:
10
Operating and Temperature
Compensated Area for
12
Regulated Output
14
Supply Voltage (Vdc)
16
18
20
22
24
26
28
30
Figure 3. Operating and Temperature Compensated Area for
4 mA to 20 mA Output
Note:
The operating area is extended with a 250 Ohm resistor.
Higher loads extend the operating area. The dashed line
indicates the operating and temperature compensated area
with a 24 V supply using a 250 Ohm load.
Characteristic
±0.25% FSS
±0.50% FSS
±3% FSS
±2% FSS
±2% FSS
±3% FSS
±10% FSS
±2% FSS
±10% FSS
±15% FSS
±5% FSS
±15% FSS
2 ms
125
120
115
110
105
100
95
90
85
80
75
70
65
60
6
10 Ohm
Load
8
Pin and Wire Codes (Option B – Packard)
A variety of pressure ports and electrical
termination connection options are available.
Refer to the “How to Order” on previous page for
possible combinations. Contact your Honeywell
representative for details.
10
Compensated Area for 4 mA
Operating and Temperature
Pin
a
b
c
12
to 20 mA Output
250 Ohm
14
Supply Voltage (Vdc)
Load
Honeywell Sensing and Control
16
+ excitation
common
Voltage
output
18
20
22
no connection
24
+ excitation
- excitation
Current
26
28
30
3