Industrial Pressure Sensors 0 psi to 30 psi min 10Vdc max 24Vdc
Manufacturer
Honeywell
Type
Gager

Specifications of SPTMA0300PG5W02

Pressure Range
0 to 300Psi
Overload Pressure (max)
1500Psi
Mounting
Stud
Pin Count
4
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Operating Supply Voltage (typ)
15/18/24V
Operating Supply Voltage (min)
12.5V
Operating Supply Voltage (max)
30V
Operating Pressure
0 psi to 300 psi
Pressure Type
Gauge
Accuracy
+/- 0.25 %
Output Type
Amplified
Mounting Style
Stud
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
10 V to 24 V
Port Size
1/4 in - 18 NPT
Pressure Port
Y
Sensor Type
Transducers
Body Style
Cylindrical
Brand/series
SPTMA
Function
Pressure
Primary Type
Pressure
Range, Measurement
300 PSI
Sensing Mode
Gage
Technology
Piezoelectric
Termination
Cable
Voltage, Supply
24 VDC
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SPTMA0300PG5W02
Manufacturer:
HIROSE
Quantity:
1
SPT mA Series 0 to 3psi to 0 to 5000psi
Performance Characteristics
Specification Notes:
Note 1: Reference Conditions (unless otherwise noted): Supply, V
Note 2: Span is the algebraic difference between the output voltage at full scale positive pressure and the output at zero
Note 3: Linearity is based on best-fit straight line from the zero to the full scale pressure. Hysteresis is the maximum
Note 4: Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 C
Note 5: Long term stability over a six month period.
Note 6: Response time for a step change from the zero pressure to the full scale pressure.
Note 7: The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
Note 8: The maximum pressure that can be applied to a transducer without rupture of either the sensing element or
External Load Line
4/6/01
Characteristic
Zero pressure offset
Full scale span
Nonlinearity
Pressure hysteresis
Repeatability
Temp. effect on span
Temp. effect on offset
Temp. effect on span (0-3psi and 0-5psi only)
Temp. effect on offset (0-3psi and 0-5psi only)
Thermal hysteresis (-10 to +85 C)
Long term stability of offset & Span
Response time (10% to 90%)
pressure.
output difference at any point within the operating pressure range for increasing and decreasing pressure.
reading.
transducer case.
(3)
(2)
(3)
(4)
(4)
(6)
(1)
(5)
(4)
(4)
S
=24 Vdc 0.01Vdc; Ta=25 C.
15.84
3.84
Min
--
--
--
--
--
--
--
--
Typical
16.0
0.015
0.010
4.0
0.1
0.5
0.5
1.5
1.5
0.1
0.1
--
16.16
4.16
0.030
Max
0.25
0.03
0.5
1.5
1.5
2.5
2.5
0.3
0.3
Units
mA
mA
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
Seconds