KD22CKY TELEDYNE, KD22CKY Datasheet

no-image

KD22CKY

Manufacturer Part Number
KD22CKY
Description
Relay SSR 15mA 18V DC-IN 5A 60V DC-OUT 6-Pin
Manufacturer
TELEDYNE
Datasheet

Specifications of KD22CKY

Output Device
Power FET
I/o Isolation Voltage
1000 V
Maximum Input Current
15 mA
Maximum Output Current
5 A
Maximum Input Voltage
18 V
Maximum Output Voltage
60 V
Output Type
DC
© 2002 TELEDYNE RELAYS
Part Number* Relay Description
KD00CK
KD02CK
KD20CK
KD22CK
LD00CM
LD02CM
LD20CM
LD22CM
* The Y suffix denotes parameters tested to MIL-PRF-28750 specifications.
ELECTRICAL SPECIFICATIONS
(-55°C TO +105°C UNLESS OTHERWISE NOTED)
When used in 2 terminal configuration
(TTL or direct control) (See Fig. 1)
Input Current @ V
Turn-Off Voltage (Guaranteed Off)
Turn-On Voltage (Guaranteed On)
Reverse Voltage Protection
Input Supply Range (See Note 1)
When used in 3 terminal configuration
(CMOS or open collector TTL) (See Fig. 1)
Control Current
Control Voltage Range
Bias Supply Voltage (See Note 1)
Bias Supply Current
Turn-Off Voltage (Guaranteed Off)
Turn-On Voltage (Guaranteed On)
The W suffix denotes parameters tested to Teledyne specifications.
V
V
CONTROL
CONTROL
5A Solid-State Relay (SSR)
5A SSR with Switch Status
5A SSR with Short-Circuit Protection
5A SSR with Short-Circuit Protection and Switch
Status
10A Solid-State Relay
10A SSR with Switch Status
10A SSR with Short-Circuit Protection
10A SSR with Short-Circuit Protection and Switch
Status
INPUT (CONTROL) SPECIFICATION
INPUT (CONTROL) SPECIFICATION
= 5 Vdc
= 18 Vdc
BIAS
= 5 Vdc (See Fig. 2)
(800) 284-7007 • www.teledynerelays.com
Min
Min
3.8
3.8
3.8
3.2
0
Typ
Typ
Max Units
Max Units
250 µAdc
1.5
-32
0.3
15
32
18
32
16
1
10A, 60Vdc Optically Isolated, Short-Circuit Protected
mAdc
mAdc
mAdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
FEATURES
• Available with short-circuit/current
• Available with switch status output
• TTL and CMOS compatible control
• Low ON resistance power FET output
• Fast switching speed
• Meets 28 Vdc system requirements of
• Optical isolation
• Low profile hermetic package
• Built and tested to the requirements of
DESCRIPTION
The Series KD and LD solid-state relays
are screened utilizing MIL-PRF-28750
test methods and are packaged in low
profile hermetically sealed cases. These
relays are constructed with state-of-the-
art solid state techniques and feature
fully
technology. This allows the load to be
connected to either output terminal and
provides a low ON resistance. The input
(control) and output are optically isolated
to protect input logic circuits from output
transients. Available options include
short circuit and current overload
protection, which provides complete
protection for both the relay and system
wiring. This feature not only provides
protection should a short or overload
occur while the relay is on, but will also
provide protection should the relay be
switched into a short. The second option
is a status output line. Switch status
returns the true status of the output
switch and is optically isolated from the
load. It provides status indication
independent of the control circuit of the
relay. The status line provides a logic 0
(low) when the relay output is off with
load voltage and continuity present, and
a logic 1 (high) when the output is on.
overload protection
MIL-STD-704
MIL-PRF-28750
floating
power
Series KD/LD
DC Solid-State Relay
FET
KD/LD\072002\Q1
output
KD/LD 51

Related parts for KD22CKY

KD22CKY Summary of contents

Page 1

... SSR with Short-Circuit Protection LD22CM 10A SSR with Short-Circuit Protection and Switch Status * The Y suffix denotes parameters tested to MIL-PRF-28750 specifications. The W suffix denotes parameters tested to Teledyne specifications. ELECTRICAL SPECIFICATIONS (-55°C TO +105°C UNLESS OTHERWISE NOTED) INPUT (CONTROL) SPECIFICATION When used in 2 terminal configuration (TTL or direct control) (See Fig ...

Page 2

... Vdc .70 Vdc 1.2 Vdc 1.4 Vdc 60 Vdc 80 Vdc .075 Ohm .075 Ohm MECHANICAL SPECIFICATION .100 Ohm .100 Ohm ±600 Vpk 1600 1000 Vac 10 9 Ohms 130 °C 150 ° °C °C/W JC Series KD/LD NO STATUS © 2002 TELEDYNE RELAYS KD/LD\072002\Q1 ...

Page 3

... Hz 5000 g 1500 g State Status Output Level Low (V ≤ 0.4 Vdc) SO High ( STATUS Min Typ Max Units 30 Vdc 10 µAdc 100 µAdc 600 µAdc 3.5 ms 8.0 ms (800) 284-7007 • www.teledynerelays.com Series KD/LD WIRING CONFIGURATIONS FIGURE 1 (See Note 1) KD/LD 53 KD/LD\072002\Q1 ...

Page 4

... FIGURE 4 (See Note 3) OUTPUT TURN-ON AND TURN-OFF TIMING FIGURE 5 SERIES LIMIT BIAS RESISTOR VS STATUS TURN-ON AND TURN-OFF TIMING FIGURE 6 CHARACTERISTICS FOR SHORT Series KD/LD TRIP (TYPICAL) FIGURE 7 BIAS VOLTAGE FIGURE 8 (See Note 1) TYPICAL TRIP CURRENT CIRCUIT CONDITIONS FIGURE 9 © 2002 TELEDYNE RELAYS KD/LD\072002\Q1 ...

Related keywords