LA00HLW TELEDYNE, LA00HLW Datasheet

no-image

LA00HLW

Manufacturer Part Number
LA00HLW
Description
Relay SSR 16mA 32V DC-IN 7.5A 250V AC-OUT 6-Pin (6+Tab)
Manufacturer
TELEDYNE
Datasheet

Specifications of LA00HLW

Input Type
DC
I/o Isolation Voltage
1250(RMS) V
Maximum Input Current
16 mA
Maximum Output Current
7.5(RMS) A
Maximum Input Voltage
32 V
Maximum Output Voltage
250(RMS) V
Output Type
AC
KA/LA 78
Part Number* Relay Description
KA00HF
KA58HF
LA00HL
LA58HL
* The Y suffix denotes parameters tested to MIL-PRF-28750 test methods.
ELECTRICAL SPECIFICATIONS
(-55°C TO +110°C UNLESS OTHERWISE SPECIFIED)
2 Terminal Configuration (See Fig. 1)
Input Voltage (See note 2)
Input Current (See Figure 1)
Turn-Off Voltage (Guaranteed Off)
Turn-On Voltage (Guaranteed On)
Reverse Voltage Protection
3 Terminal Configuration (See Fig. 1)
Bias Voltage (See note 2)
Bias Current (V
Control Voltage Range
Control Current (at 5 Vdc)
Turn-On Control Voltage
Turn-Off Control Voltage
Load Voltage
Frequency Range
Continuous Load Current (See Figure 3)
Output Voltatge Drop
The W suffix denotes parameters tested to Teledyne specifications.
V
KA and LA without Heat Sink
LA with Heat Sink
IN
= 5 Vdc
2 A, 250 Vrms, AC Solid-State Relay
2 A, 250 Vrms, AC Solid-State Relay with Thermal
Protection and Thermal TRIP Status
7.5 A, 250 Vrms, AC Solid-State Relay
7.5 A, 250 Vrms, AC Solid-State Relay with Thermal
Protection and Thermal TRIP Status
IN
INPUT (CONTROL) CHARACTERISTICS
INPUT (CONTROL) CHARACTERISTICS
=32 Vdc)
OUTPUT (LOAD) SPECIFICATIONS
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
Min
Min
Min
3.8
3.8
3.8
3.2
20
40
0
Max
Max
Max
250
250
440
-32
0.3
1.5
2.0
7.5
1.2
32
15
32
16
18
mA dc
Units
Units
Units
µAdc
Vrms
Arms
Arms
Vrms
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
mA
Hz
2.0 to 7.5A, 250 Vrms Optically Isolated
FEATURES/BENEFITS
• Available with thermal protection
• Optical Isolation: Isolates control
• Fully Floating Output: Eliminates
• Buffered Control: Relay can be
• Integral Snubber Circuit: Enhances
DESCRIPTION
The Series KA/LA solid-state relays
(SSRs) is designed for use in AC
power switching applications where
safety and reliability are primary
concerns. These SSRs are rated for
load voltages up to 250 Vrms from 40
to 440 Hz and are ideal for resistive
and reactive loads with power factors
as low as 0.2. Inverse parallel SCRs
are configured for zero voltage turn on.
Optical isolation to 1250 Vrms between
the control (input) and load (output)
allows the load to be safely controlled
by logic circuitry. The KA/LA series is
available with thermal protection and
thermal TRIP status. In case of a
thermal runaway condition, the SSR
will shut down the output switch and
latch off until the input is reset and the
junction temperature returns to a safe
level. When the output does latch off,
the TRIP status line will yield a logic
level output indicating the protection
state of the SSR. This feature provides
the user with failure mode indication
while enhancing the system diagnostic
capability. These SSRs are available to
the Y screening level of MIL-PRF-
28750 and are packaged in low-profile
hermetically sealed cases.
and thermal TRIP status: Provides
self-protection from thermal
runaway conditions and indicates
protection state for system BIT.
elements from load transients with
reduced EMI.
ground potential loops and allows
the output to sink or source current.
controlled directly from TTL or
CMOS logic circuits.
dV/dt capability while minimizing
EMI.
© 2002 TELEDYNE RELAYS
Series KA/LA
AC Solid-State Relay
KA/LA\072002\Q1

Related parts for LA00HLW

LA00HLW Summary of contents

Page 1

... LA58HL 7.5 A, 250 Vrms, AC Solid-State Relay with Thermal Protection and Thermal TRIP Status * The Y suffix denotes parameters tested to MIL-PRF-28750 test methods. The W suffix denotes parameters tested to Teledyne specifications. ELECTRICAL SPECIFICATIONS (-55°C TO +110°C UNLESS OTHERWISE SPECIFIED) INPUT (CONTROL) CHARACTERISTICS 2 Terminal Configuration (See Fig. 1) ...

Page 2

... MIL-PRF-28750 0.2 MECHANICAL SPECIFICATIONS 9 10 Ohm 15 pF 1250 Vrms o Max) 125 C C/W JC Output (Load) State On Tripped (Off) Off Non-applicable condition Min Max Units 32 Vdc 10 µAdc 10 mAdc DIMENSIONS ARE SHOWN IN INCHES 0.4 Vdc (800) 284-7007 • www.teledynerelays.com Series KA/LA (MILLIMETERS) KA/LA 79 KA/LA\072002\Q1 ...

Page 3

... Transient suppression must be used to limit the voltage to < 500 Vpeak when switching inductive loads. KA/LA 80 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Min Max Units o -55 +110 C -55 +125 o C 1500 g 10 3000 Hz 5000 g WIRING CONFIGURATION Series KA/LA FIGURE 1 (See Note 1 & 2) © 2002 TELEDYNE RELAYS KA/LA\072002\Q1 ...

Page 4

... TELEDYNE RELAYS TYPICAL VOLTAGE DROP VS LOAD CURRENT OF LA SERIES WITH 1 SERIES LIMIT BIAS RESISTOR VS BIAS VOLTAGE FIGURE 6 (SEE NOTE 2) TYPICAL THERMAL TRIP TIME KA58HF AND LA58HL (800) 284-7007 • www.teledynerelays.com Series KA/LA ° C/W HEATSINK FIGURE 5 FIGURE 7 KA/LA 81 KA/LA\072002\Q1 ...