SCD20CDY TELEDYNE, SCD20CDY Datasheet

no-image

SCD20CDY

Manufacturer Part Number
SCD20CDY
Description
Relay SSR 15mA 18V DC-IN 1A 60V DC-OUT 6-Pin CDIP SMD
Manufacturer
TELEDYNE
Datasheet

Specifications of SCD20CDY

Package
6CDIP SMD
Output Device
Power FET
I/o Isolation Voltage
1000 V
Maximum Input Current
15 mA
Maximum Output Current
1 A
Maximum Input Voltage
18 V
Maximum Output Voltage
60 V
Output Type
DC
© 2002 TELEDYNE RELAYS
Part*
Number
CD00CFW
CD00CFY
CD01CFW
CD01CFY
CD20CDW
CD20CDY
CD21CDW
CD21CDY
* The Y suffix denotes parameters tested to MIL-PRF-28750 specifications.
ELECTRICAL SPECIFICATIONS
(-55°C TO +105°C UNLESS OTHERWISE NOTED)
When used in 2 terminal configuration
(TTL or direct control) (See Fig. 1)
Input Current @ V
Turn-Off Voltage (Guaranteed Off)
Turn-On Voltage (Guaranteed On)
Reverse Voltage Protection
Input Supply Range (See Note 4)
When used in 3 terminal configuration
(CMOS or open collector TTL) (See Fig. 1)
Control Current
Control Voltage Range
Bias Supply Voltage (See Note 4)
Bias Supply Current @ V
Turn-Off Voltage (Guaranteed Off)
Turn-On Voltage (Guaranteed On)
The W suffix denotes parameters tested to Teledyne specifications.
For surface mount (SMT), add “S” prefix to part number. Example:
SCD00CFW
V
V
CONTROL
CONTROL
= 5 Vdc
= 18 Vdc
DESC Drawing
90091-008
90091-006
90091-004
90091-002
IN
Number
INPUT (CONTROL) SPECIFICATION
INPUT (CONTROL) SPECIFICATION
= 5 Vdc (See Fig. 2)
BIAS
= 5 Vdc
Relay Description
Basic Solid-State Relay (SSR)
SSR with Control Status
SSR with Short-Circuit Protection
SSR with Short-Circuit Protection
and Control Status
(800) 284-7007 • www.teledynerelays.com
Min
Min
3.8
3.8
3.8
3.2
0
Typ
Typ
14
14
Max Units
Max Units
250
1.5
-32
0.3
15
18
15
6
1
6
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
2A, 60Vdc Optically Isolated, Short-Circuit Protected
mA
mA
mA
µA
FEATURES
• Available with short circuit/current
• Available with input status monitor
• TTL and CMOS compatible control
• Low ON resistance power FET output
• Fast switching speed
• Meets 28 Vdc system requirements of
• Optical isolation
• Low profile hermetic ceramic package
• Built and tested to the requirements of
DESCRIPTION
This all solid-state relay utilizes the
latest technology to provide a low ON
resistance. The control (input) and load
(output) are optically isolated to protect
input logic circuits from voltage and
current transients which can occur on
the output supply. The optical isolation
also provides a full floating output, thus
allowing the load to be connected to
either output terminal. The control circuit
is buffered to enable the relay to be
driven directly from standard CMOS or
open collector TTL logic circuits.
Available options include short circuit
and current overload protection, which
provides complete protection for both
the relay and the system wiring. This
feature not only provides protection
should a short or overload occur while
the relay is on, but will also provide
protection should the relay be switched
into a short. In either case, the relay will
sense the short circuit condition and
then block it indefinitely until the short is
removed and the unit is reset by cycling
the input control. The second option is a
status output, which provides a built-in-
test function. This feature checks the
input circuitry of the relay and provides a
logic (0) low when the input circuit is
turned on and operational. Both options
are
separately as standard features.
overload protection
MIL-STD-704
MIL-PRF-28750
available
either
DC Solid-State Relay
Series CD
together
CD\072002\Q1
or
CD 41

Related parts for SCD20CDY

SCD20CDY Summary of contents

Page 1

... SSR with Short-Circuit Protection and Control Status CD21CDY 90091-002 * The Y suffix denotes parameters tested to MIL-PRF-28750 specifications. The W suffix denotes parameters tested to Teledyne specifications. For surface mount (SMT), add “S” prefix to part number. Example: SCD00CFW ELECTRICAL SPECIFICATIONS (-55°C TO +105°C UNLESS OTHERWISE NOTED) ...

Page 2

... Ohm 0.36 0.45 Ohm 0.16 0.22 Ohm 0.16 0.22 Ohm 1.5 ms 0.25 ms ±600 Vdc 475 1000 Vac 9 10 Ohm Max) 150 °C 150 ° °C °C/W JC Min Typ Max Units 30 Vdc 4 µAdc 2 mAdc Series CD MECHANICAL SPECIFICATIONS © 2002 TELEDYNE RELAYS CD\072002\Q1 ...

Page 3

... TELEDYNE RELAYS Min Typ Max Units 2.4 Adc Min Typ Max Units -55 +105 °C -55 +125 °C 10 3000 Hz 5000 g 1500 g Status Output Level High ( STATUS Low (V ) ≤ 0.3 Vdc) SO WIRING CONFIGURATIONS FIGURE 1 (SEE NOTE 8) (800) 284-7007 • www.teledynerelays.com Series CD\072002\Q1 ...

Page 4

... Select the status resistor such that it does not allow more than flow through the status output 0.3V STATUS STATUS Iso 8. Inductive loads should be diode suppressed. Input transitions should be ≤ duration and the input drive should be a bounceless contact type. © 2002 TELEDYNE RELAYS Series CD CD\072002\Q1 ...

Related keywords