SH48R35 TELEDYNE, SH48R35 Datasheet

no-image

SH48R35

Manufacturer Part Number
SH48R35
Description
Relay SSR 13mA 32V DC-IN 35A 510V AC-OUT 3-Pin
Manufacturer
TELEDYNE
Datasheet

Specifications of SH48R35

Input Type
DC
Output Device
Triac
I/o Isolation Voltage
4000(Min) V
Maximum Input Current
13 mA
Maximum Output Current
35 A
Maximum Input Voltage
32 V
Maximum Output Voltage
510 V
Output Type
AC
© 2008 TELEDYNE RELAYS
FEATURES/BENEFITS
• Random and zero-cross models available for all applications
• Low zero-cross turn-on voltage
• Input and output protection and control LED standard
• IP20 touch-proof fl aps
• Connectors for power wiring and heat sinks available
• Designed in conformity with EN60947-4-3 (IEC947-4-3) and
Part No.
SH24D25
SH24A25
SH24D35
SH24A35
SH24D50
SH24R50
SH24R75
SH24D75
SH24D95
SH24D125
SH48R35
SH48D35
SH48A35
SH48R50
SH48D50
SH48A50
SH48R75
SH48D75
SH48A75
SH48R95
SH48D95
SH48A95
SH48R125
SH48D125
SH48A125
SH60D50
SH60D75
SH60D95
SH60D125
EN60950/VDE0805 (Reinforced Insulation)
12-275 Vac
12-275 Vac
12-275 Vac
12-275 Vac
12-275 Vac
12-275 Vac
12-275 Vac
12-275 Vac
12-275 Vac
12-275 Vac
24-510 Vac
24-510 Vac
24-510 Vac
24-510 Vac
24-510 Vac
24-510 Vac
24-510 Vac
24-510 Vac
24-510 Vac
24-510 Vac
24-510 Vac
24-510 Vac
24-510 Vac
24-510 Vac
24-510 Vac
24-690 Vac
24-690 Vac
24-690 Vac
24-690 Vac
Voltage
Load
Current
Load
125A
125A
125A
125A
125A
25A
25A
35A
35A
50A
50A
75A
75A
95A
35A
35A
35A
50A
50A
50A
75A
75A
75A
95A
95A
95A
50A
75A
95A
20-265 Vac/dc
20-265 Vac/dc
20-265 Vac/dc
20-265 Vac/dc
20-265 Vac/dc
20-265 Vac/dc
20-265 Vac/dc
3.5-32 Vdc
3.5-32 Vdc
3.5-32 Vdc
3.5-32 Vdc
3.5-32 Vdc
3.5-32 Vdc
3.5-32 Vdc
3.5-32 Vdc
3.5-32 Vdc
3.5-32 Vdc
3.5-32 Vdc
3.5-32 Vdc
3.5-32 Vdc
3.5-32 Vdc
3-32 Vdc
3-32 Vdc
3-32 Vdc
3-32 Vdc
3-32 Vdc
3-32 Vdc
3-32 Vdc
3-32 Vdc
Control
Voltage
(800) 284-7007 • www.teledynerelays.com
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Random
Random
Random
Random
Random
Random
Random
Switch
Type
High Industrial Performance (HIPpak) Solid-State Relays
IP20 touch-proof fl aps
Figure 1c — SHXXRXX relays
Figure 1a — SHXXDXX relays
Figure 1b — SHXXAXX relays
TYPICAL APPLICATION
Output to 125A, 690 Vac
NEW Series SH
SH\102008\Q4
SH Page 1

Related parts for SH48R35

SH48R35 Summary of contents

Page 1

... SH24R50 12-275 Vac 50A SH24R75 12-275 Vac 75A SH24D75 12-275 Vac 75A SH24D95 12-275 Vac 95A SH24D125 12-275 Vac 125A SH48R35 24-510 Vac 35A SH48D35 24-510 Vac 35A SH48A35 24-510 Vac 35A 20-265 Vac/dc SH48R50 24-510 Vac 50A SH48D50 24-510 Vac ...

Page 2

... SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE High Industrial Performance (HIPpak) Solid-State Relays CONTROL CHARACTERISTICS Max Units 2.0 Vdc 5.0 Vdc Figure 3a — SH24R/D, SH48R/D relays 0.185 ( ) Figure 3b — SH24A, SH48A relays Figure 3c — SH60D relays NEW Series SH Output to 125A, 690 Vac © 2008 TELEDYNE RELAYS SH\102008\Q4 ...

Page 3

... Conducted Immunity Level 2 W IEC/EN61000-4-4 (bursts) SH24 SH48/SH60 NA ±12 Vac IEC/EN61000-4-5 (surge) SH24 SH48 3 mA SH60 4kV criterion A (with external VDR (800) 284-7007 • www.teledynerelays.com NEW Series SH Output to 125A, 690 Vac 0.04 ms 8.3 ms 24.9 ms 8.3 ms 24.9 ms 500 V/μs 50 A/μs 0.1 ...

Page 4

... Output-Case Isolation 4000 Insulation Resistance @500Vdc 1000 Rated Impulse Voltage Protection Level (CEI529) Vibration (10–55 Hz according to CE168) Shock (according to CD168) Housing Material PA6 UL94VO Baseplate Aluminum, nickel-plated © 2008 TELEDYNE RELAYS Max Units +80 °C +80 °C +125 °C +125 ° Vrms Vrms MΩ ...

Page 5

... Figure 5a — 25A output power Figure 5c — 50A output power Figure 5e — 95A output power 12°C/W corresponds to a relay without heat sink 6°C/W corresponds to a relay mounted on a DIN-rail adaptor (Teledyne P/N DL12) © 2008 TELEDYNE RELAYS High Industrial Performance (HIPpak) Solid-State Relays THERMAL CURVES Figure 5b — ...

Page 6

... Fastons: Call us Special kit for high current AWG2 / 35mm 2 AWG0 / 50mm 2 NEW Series SH Output to 125A, 690 Vac With special adaptation for high-voltage relays Screwdriver Recommended Type Torque N.m Pozidriv 2 0.8 Screwdriver Recommended Type Torque N.m Pozidriv 2 1.2 © 2008 TELEDYNE RELAYS SH\102008\Q4 ...

Page 7

... HIPpak SSRs must be mounted on heat sinks. A large range of heat sinks is available. For heat-sink mounting, use thermal grease or a thermal pad with high conductibility specifi ed by Teledyne. DIN Rail Adapter Teledyne P/N DL12 Typical Loads (Random) SH relays with random turn-on are designed for high inductive loads or phase angle control applications. ...

Page 8

... SSRs are complex devices that must be interconnected with other equipment (loads, cables, etc.) to form a system. Because the other equipment or interconnections may not be under Teledyne’s control, it shall be the responsibility of the system integrator to ensure that systems containing SSRs comply with the requirement of any rules and regulations applicable at the system level. • ...