PFP-100N2 Omron, PFP-100N2 Datasheet
PFP-100N2
Specifications of PFP-100N2
PFP100N2
Z2611
Related parts for PFP-100N2
PFP-100N2 Summary of contents
Page 1
Switching Power Supply Compact and Economical Switching Power Supply Models range from Open-frame and covered types Wide range of output voltage: 5-, 12-, 15- and 24-V models UL, CSA approved 3-year warranty Ordering Information ...
Page 2
... L drop type, automatic reset Yes (5-V output models only) (This table continues on the next page.) S8E1 3. Configuration A: Open-frame type, front terminals D: Covered-type, front terminals Part number PFP-50N PFP-100N PFP-100N2 Part number 15 S82Y-01N S82Y-03N S82Y-10N 0.7 A max. ...
Page 3
... OUTPUT MODELS ONLY) Models with a power rating incorporate a Zener diode clamp circuit. If the protection circuit is triggered, contact your OMRON representative for repairs. Models with a power rating incorporate a shut-off circuit. If the protection circuit is triggered, turn off the input power and leave the power supply off for at least one minute before turning it on again ...
Page 4
S8E1 OVERLOAD PROTECTION The power supply has an overload protection function that protects the load and the power supply from possible damage by overcurrent. When the output current rises above a set value (105% of the rated output current), ...
Page 5
... If operation amplifiers as loads are connected in series, connect a diode between the positive and negative output terminals of each power supplies as shown in the illustration below. Consult your OMRON representative for the specifications of the diode. No diode is necessary for models with power ratings Input ...
Page 6
S8E1 Dimensions Unit: mm (inch) SWITCHING POWER SUPPLIES 10W Open-frame Type/Covered Type 12 max. 85 (3.35) 8.2 9.5 Five terminal 24 24.5 screws 28 R1.75 3.5 dia. Two, M3 holes ...
Page 7
... L2 114.8 mm (4.52) Note: The figures in row L1 are applied if a mounting bracket is attached to the power supply. The figures in row L2 are applied if either PFP-50N or PFP-100N DIN rail is used. Add 10 each figure in the L1 row if PFP-100N2 DIN rail is used. DIN RAIL (ORDER SEPARATELY) PFP-100N/PFP-50N 4 ...
Page 8
... Forced-air cooling is recommended. Air Metal plate 20 mm NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS, INC. One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC PS5 7/99 Open-Frame and Covered-Type (A). Side mounting (B) ...