E5CSV-R1T-F AC100-240 Omron, E5CSV-R1T-F AC100-240 Datasheet

CONTROL TEMP DGTL RELAY OUT

E5CSV-R1T-F AC100-240

Manufacturer Part Number
E5CSV-R1T-F AC100-240
Description
CONTROL TEMP DGTL RELAY OUT
Manufacturer
Omron
Series
E5CSVr
Type
Temperature Controller, Digitalr

Specifications of E5CSV-R1T-F AC100-240

Input Type
RTD, Thermocouple (Multiple)
Controller Type
On/Off or Proportional (PID)
Temperature Range
Selectable, Varies By Input Type
Output Type
Relay
Supply Voltage
100 ~ 240VAC
Size
48mm W x 48mm H (1/16 DIN)
Display Type
4 Digit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Communications
-
Other names
E5CSV-R1T-F-AC100-240
E5CSV-R1T-F-AC100240
E5CSVR1TFAC100240
Z2695
Simple to Set and Operate 1/16 DIN Size
Controllers
• Easy setting using internal DIP and rotary switches
• ON/OFF or PID control (with on-demand auto-tuning)
• Clearly visible digital display with character height of 13.5 mm
• Deviation indicator makes monitoring more effective
• Multiple temperature sensor input (thermocouple/platinum
• Models with two alarms are ideal for temperature alarm
• Setting change protection prohibits tampering
• Sampling rate (500 ms) and selectable control period (2 and
• 8-mode alarm output and sensor error detection
• “Input shift” function adjusts display to reflect known sensor
Model Number Structure
■ Model Number Legend
Models with Terminal Blocks
1. Output type
2. Number of alarms
3. Input type
Note: A functional explanation is provided here for illustration, but models are not necessarily available for all possible combinations.
selectable
resistance thermometer) models stocked; thermocouple
input only and platinum RTD input only models available
applications
20 s) improves response
offsets
Temperature Controllers
E5CSV
R:
Q:
Blank:No alarm
1:
2:
T:
KJ:
P:
Please refer to Ordering Information when ordering.
Examples
• Voltage control output, without alarm, multi-input, light gray case: 115 VAC: E5CSV-QT-W AC100-240
• Relay control output, one alarm output, multi-input, black case: 24 VDC: E5CSV-R1TD AC/DC24
Relay
Voltage for driving SSR
1 alarm
2 alarms
Thermocouple/platinum resistance thermometer
(multi-input)
Thermocouple
Platinum resistance thermometer
1 2 3 4
5 6
• ° C or ° F field selectable
• Black or white cases available to match panel aesthetics
• RoHS compliant
• Water-resistant front panel rated NEMA 4X/IP66
• Compact: measures 48 H x 48 W x 78 D mm
• Accuracy ±0.5% of value
4. Power supply voltage
5. Case color / Display scale
6. Power supply voltage
Blank:
D:
Blank:
W:
F:
AC100-240: 100 to 240 VAC
AC/DC24: 24 VAC/VDC
Temperature Controllers
100 to 240 VAC
24 VAC/VDC
Black
Light gray
Scale marked in ° F (Black case only)
E5CSV

E5CSV-R1T-F AC100-240 Summary of contents

Page 1

... Examples • Voltage control output, without alarm, multi-input, light gray case: 115 VAC: E5CSV-QT-W AC100-240 • Relay control output, one alarm output, multi-input, black case: 24 VDC: E5CSV-R1TD AC/DC24 • ° ° F field selectable • Black or white cases available to match panel aesthetics • ...

Page 2

... E5CSV Pt input TC/Pt multi-input Case color: Case color: Black Scale marked in ° F Light gray Scale marked in ° C E5CSV-RT-F AC100-240 E5CSV-QT-F AC100-240 E5CSV-R1P-W E5CSV-R1T-F AC100-240 E5CSV-Q1P-W E5CSV-Q1T-F AC100-240 E5CSV-R2T-F AC100-240 E5CSV-Q2T-F AC100-240 E5CSV-R1TD-F AC/DC24 E5CSV-Q1TD-F AC/DC24 24 VAC/VDC, 50/ VA Pt100, JPt100 Pt100, JPt100 ...

Page 3

... C ±1 digit max. at 200° less 2. The following exceptions apply to platinum resistance ther- mometers. Input set values for E5CSV: 0.5% FS ±1 digit max. Input set value 1 for E5CSV: 0.5% FS ±1 digit max. ■ Electrical Life Expectancy Curve for Relays (Reference Values) ...

Page 4

... C Pt100 JPt100 500 400 200 199 0.0 –99 –99 – 1° C 0.1° C E5CSV 500 400 The shaded value indicates the default setting status. 400 199 The shaded value indicates the default 0.1° C setting status 1,700 1,300 0 – ...

Page 5

... Otherwise, unwanted current paths will cause measurement errors. 2. Models with 100 to 240 VAC and 24 VAC/VDC are separate. Models using 24 VDC have no polarity. 3. The number of alarm outputs depends on the model. Nomenclature E5CSV Models with Terminal Blocks Deviation indicators Mode indicators Mode Key ...

Page 6

... Lock Release Key. 3. When inserting the E5CSV, check to make sure that the sealing rubber is in place and push the E5CSV toward the rear case until it snaps into position. While pushing the E5CSV into place, push down on the hooks on the top and bottom surfaces of the rear case so that the hooks are securely locked in place ...

Page 7

... Press the Key. first. The alarm value will be changed auto- matically to the maximum value in the new temperature range. Press the Key. Press the Key. Press the Key. E5CSV 400 200 ...

Page 8

... L in accordance with revisions to DIN stan- dards. Note: Turn OFF the power before changing the DIP switch settings on the E5CSV. Each of the switch settings will be enabled after the power is turned ON. For details on the position of the temperature range switch, control mode switches, and alarm mode switch, refer to page 6. ...

Page 9

... AT is executing during AT operation. Flashing stops when AT is completed. AT execution AT cancelled Note: One of the deviation indicators (▲■▼) will flash. Temperature Controllers Control output ON OFF Output level Output level Press for at least execution in progress U D Press for at least execution in progress E5CSV 9 ...

Page 10

... Using the E5CSV in Devices for Fahrenheit-scale Users (Displaying in ° F) Turn ON switch 6 to display temperatures in ° Temperature Range for ° F The temperature is set to ° F using the same temperature range switch as ° C. Thermocouple Platinum Resistance Thermometer ° F Set- Set- ting ting 200 300 ...

Page 11

... Insert the E5CSV into the mounting hole in the panel. 3. Push the adapter from the terminals up to the panel, and temporarily fasten the E5CSV. 4. Tighten the two fastening screws on the adapter. Alternately tighten the two screws little by little to maintain a balance. Tighten the screws to a torque of 0.29 to 0.39 N· ...

Page 12

... Control output fff flashing OFF --- flashing OFF fff flashing OFF --- flashing OFF E5CSV Control output Heating control (reverse operation): OFF Cooling control (direct operation): ON Heating control (reverse operation): ON Cooling control (direct operation): OFF OFF OFF The control outputs and alarm outputs ...

Page 13

... Terminal X Model with terminal block appearance Main Differences Terminal block models use the model number E5CSV. The suffix “D” is added to models with a supply voltage of 24 VAC/VDC. The suffix “W” is added to models with a light gray case color. ■ Display Previous model ...

Page 14

... Platinum resistance thermometer input ■ DIP Switch and Rotary Switch Setting Methods No change from previous models. 14 Temperature Controllers Voltage output 10 5 ALARM Platinum resistance thermometer input Multi-input (thermocouple/platinum resistance thermometer) E5CSV E5CSV Relay output VDC Alarm output 2 Alarm output ...

Page 15

... Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Controller E5CSV 48×48 E5CSV + Adapter for Flush Mounting (Provided) Hard Protective Cover The Y92A-48B Protective Cover (hard type) is available for the following applications. • To protect the set from dust and dirt. ...

Page 16

... When a noise filter is used at the power supply, first check the voltage or current, and attach the noise filter as close as possible to the temperature controller. Allow as much space as possible between the Temperature Con- troller and devices that generate powerful high frequencies (high- frequency welders, high-frequency sewing machines, etc.) or surge. E5CSV 2 ). ...

Page 17

... If the measurement accuracy is low, check whether the input shift has been set correctly. Waterproofing The degree of protection is as shown below. Sections without any specification on their degree of protection or those with IP@0 are not waterproof. Front panel: IP66, rear case: IP20, terminals: IP00 E5CSV Temperature Controllers 17 ...

Page 18

... OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. 18 Temperature Controllers Read and Understand this Catalog Warranty and Limitations of Liability Application Considerations Disclaimers E5CSV ...

Page 19

... Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. 5. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. E5CSV Temperature Controllers 19 ...

Page 20

... Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at www.omron.com/oei – under the “About Us” tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. ...