E5AK-AA2-500 Omron, E5AK-AA2-500 Datasheet

CONTROL TEMP DIGITAL HEAT/COOL

E5AK-AA2-500

Manufacturer Part Number
E5AK-AA2-500
Description
CONTROL TEMP DIGITAL HEAT/COOL
Manufacturer
Omron
Series
E5AKr
Type
Digital Controllerr
Datasheets

Specifications of E5AK-AA2-500

Input Type
Current, Voltage, RTD, Thermocouple (Multiple)
Controller Type
On/Off
Temperature Range
Selectable, Varies By Input Type
Output Type
Output Units Available
Supply Voltage
100 ~ 240VAC
Size
96mm W x 96mm H (1/4 DIN)
Features
Burnout Detection, Terminal Cover
Display Type
4 Digit (2); Bar Graphs, LEDs
Analog / Digital
Digital
Control Method
ON/OFF, PID Control
Voltage Rating
100 VAC to 240 VAC
Mounting
Horizontal
Operating Temperature Max
50°C
Operating Temperature Min
-10°C
Temperature Accuracy ±
0.3%
Output Voltage Max
250VAC
Length/height, External
96mm
External Width
96mm
Supply Voltage Max
240VAC
Mounting Type
1/4 DIN
Supply Voltage Min
100VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Communications
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E5AKAA2500
Z2412
Advanced Digital Controllers Ideal for
Worldwide Use
• Modular structure
• High-accuracy: 100 ms sampling (for analog input)
• Auto-tuning and fuzzy self-tuning
• Conforms to international EMC and safety standards.
• IP66/NEMA4 (indoor use) front face
• Remote set point
• Serial communications (RS-232C, RS-422 and RS-485) and
• Position-proportional control model
• Heating/cooling control
Model Number Structure
■ Model Number Legend
1. Model
2. Number of alarms
E5AK- @@@ @ -500
transfer output (4 to 20 mA)
Digital Controller
E5AK
AA:
PRR: Position-proportional model
T:
2:
Refer to Safety Precautions for All Temperature Controllers.
Standard model
Programmable type
Two alarms
1
2
Refer to E5
procedures.
@
K Operation for operating
CSM_E5AK_DS_E_3_1
1

E5AK-AA2-500 Summary of contents

Page 1

... Remote set point • Serial communications (RS-232C, RS-422 and RS-485) and transfer output ( mA) • Position-proportional control model • Heating/cooling control Refer to Safety Precautions for All Temperature Controllers. Model Number Structure ■ Model Number Legend E5AK- @@@ @ -500 Model AA: Standard model PRR: Position-proportional model T: Programmable type 2 ...

Page 2

... Ordering Information ■ List of Models Description Base Unit E5AK-AA2 AC100-240 E5AK-AA2-500 AC100-240 E5AK-PRR2 AC100-240 E5AK-PRR2-500 AC100-240 E5AK-TAA2 AC100-240 E5AK-TAA2-500 AC100-240 E5AK-TPRR2 AC100-240 E5AK-TPRR2-500 AC100-240 Note: 1. When using the heater burnout alarm function with a standard model, the Linear Output Unit cannot be used for the control outputs (heat). ...

Page 3

... Conforms to IEC IP66 and NEMA4 (Indoor use) Note: Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Temperature Controllers. *1.All control outputs are isolated electrically from the input circuits. *2.The E5AK-T/-TP do not support fuzzy self-tuning. Model 5 ...

Page 4

... L2 −199.9 −100 −199.9 0 0.0 to 400.0 to 400.0 600 to 850 400.0 to 400.0 −199.9 −100 −199.9 0 0.0 to 750.0 to 700.0 1,100 to 750.0 to 700.0 1,500 Voltage input E5AK −200 100 1,700 1,700 1,800 2,300 1,300 −300 300 3,000 3,000 3,200 4,100 2,300 PLII 0 to 1,300 0 to ...

Page 5

... Operating: Degree of protection Front panel: NEMA4 for indoor use (equivalent to IP66) Rear case: Terminals: Memory protection Non-volatile memory (number of writings: 100,000 operations) Weight E5AK: approx. 450 g E5EK: approx. 320 g Mounting bracket: approx EMC Emission Enclosure: Emission AC Mains: Immunity ESD: Immunity RF-interference: ...

Page 6

... Synchronization method: Start-stop synchronization (asynchronous method) RS-422 Baud rate: 1.2/2.4/4.8/9.6/19.2 kbps RS-485 Transmission code: ASCII mA: Permissible load impedance: 600 Ω max. Resolution: approx. 2,600 2 (10G) Single-phase 50 A VAC (See note 1.) ±5% FS±1 digit max. 0.1 to 49.9 A (in units of 0.1 A) (See note 2.) 190 ms (See note 3.) E5AK Specifications 6 ...

Page 7

... AT Flashes during auto-tuning. • RSP Lights during remote SP opera- tion. • Bar Graph On a standard model (E5AK- AA2), this bar graph indicates the manipulated variable (heat) in 10% increments per single segment position- proportional model (E5AK-PRR2), this bar graph indicates the valve opening in 10% increments per single segment ...

Page 8

... E54-CT1 120 min. Note: 1. Recommended panel thickness mm. 2. Maintain the specified vertical and horizontal mounting space between each Unit. Units must not be closely mounted vertically or horizontally. E54-CT3 5.8 dia. E5AK Panel Cutouts 110 min. E53-COV08 2.36 dia. 12 dia. 40x40 Two, M3 (depth: 4) ...

Page 9

... Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required. E5AK 9 ...

Page 10

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...