E5C2-R20K AC200-240 0-200 Omron, E5C2-R20K AC200-240 0-200 Datasheet - Page 3

no-image

E5C2-R20K AC200-240 0-200

Manufacturer Part Number
E5C2-R20K AC200-240 0-200
Description
CONTROLLER TEMP ON/OFF 200V
Manufacturer
Omron
Series
E5C2r
Type
Temperature Controller, Analogr

Specifications of E5C2-R20K AC200-240 0-200

Input Type
Thermocouple (K)
Controller Type
On/Off
Temperature Range
0 ~ 200°C
Output Type
Relay
Supply Voltage
200 ~ 240VAC
Size
48mm W x 48mm H (1/16 DIN)
Features
8-Pin Plug In Mounting
Display Type
Scale
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Communications
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E5C2-R20KAC200-2400-200
E5C2R20KAC2002400200
■ Connections
Connecting the Input
• Connect a thermocouple, the E52-THE@ Thermistor (replaceable
• On the E52-@@1D, the lead wires are thermocouple element wires,
Nomenclature
element) or a platinum resistance thermometer to terminals 1
(positive) and 2 (negative) on the E5C2 as shown in the following
illustration.
making them difficult to solder because solder will not stick to them
easily. Remove the crimp terminal and polish the ends before
attempting to solder them.
Thermocouple input
Thermistor with
replaceable element
Temperature setting knob
Platinum resistance
thermometer input
RESET adjustment shaft
No reset function is incorporated by any
E5C2 model with ON/OFF control.
Power supply
100/110/120 VAC (same model) or
200/220/240 VAC (same model)
50/60 Hz
Operation indicator
Output
• If the load circuit is a heating control system, be sure to connect the
• We recommend using an external relay to extend the electrical life
Power Supply
• If a single power supply is used for the E5C2 and the load, the
• The E5C2 operates at either 50 or 60 Hz.
• Different models must be order for 100 to 120 VAC and 200 to
Operation Indicator
Red Lit
load to terminals 4 and 5. If the load circuit is a cooling control
system, be sure to connect the load to terminals 4 and 6.
of internal relays when driving a large capacity load. This is
particularly important when the output relay is switched frequently
(e.g., with proportional control).
supply voltage of the power supply may vary greatly when the load
is open or closed if the capacity of the power supply is not large
enough. Make sure that the capacity of the power supply is large
enough so that the supply voltage range will be always from 90% to
110% of the rated supply voltage.
240 VAC.
Indicator
Not lit
NO contacts (4 and 5) NC contacts (4 to 6)
ON
OFF
Output
OFF
ON
E5C2
3