E5ZE-8VQAD1TCB-V2 DC24 Omron, E5ZE-8VQAD1TCB-V2 DC24 Datasheet

no-image

E5ZE-8VQAD1TCB-V2 DC24

Manufacturer Part Number
E5ZE-8VQAD1TCB-V2 DC24
Description
CONTROLLER TEMP 24V THERMOCOUPLE
Manufacturer
Omron
Series
E5ZEr
Type
Temperature Controller, Multipointr
Datasheet

Specifications of E5ZE-8VQAD1TCB-V2 DC24

Input Type
Thermocouple (Multiple)
Controller Type
Proportional (PID)
Temperature Range
Selectable, Varies By Input Type
Output Type
Voltage
Supply Voltage
24VDC
Size
65mm W x 243mm H
Display Type
Separate Display Available
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Communications
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E5ZE-8VQAD1TCB-V2DC24
E5ZE8VQAD1TCBV2DC24
Controls Up to Eight Zones, Built-in
DeviceNet Communications
H
H
H
H
H
Ordering Information
J TEMPERATURE CONTROLLERS
Note: 1. The output operation can be switched to provide cooling control.
J ACCESSORIES (ORDER SEPARATELY)
Control
Control
points
points
8
8
Description
Display unit shows
Display unit shows
settings, allows
settings, allows
programming without
programming without
software; 1/4 DIN size
software; 1/4 DIN size
Current transformer;
order only if using heater
order only if using heater
burnout alarm function
Software
I/O cable to E5ZE
DeviceNet connectors
DeviceNet connectors
Multi--point Temperature Controller
Applications include plastic injection and
extrusion machines, and continuous
temperature control processes
DeviceNet allows the controller to
communicate with a remote I/O master
without programming, or communicate
directly with an Omron PLC via explicit
messaging
Fast sampling rate of 0.2 s for 8 inputs
Optional 1/4 DIN size Display Unit shows
temperature and settings for each zone
without using software
3-year warranty
2. Models are available without the Heater open circuit/SSR fault detection functions.
3. Number of connectable units will be limited according to remote I/O points at host system.
Control method
Control method
Heat
Heat
(See Note 1)
(See Note 1)
Heat and cool
Heat and cool
Specifications
RS-232C connection; 100 to 240 VAC, 50/60 Hz supply voltage
RS-232C connection; 24 VDC supply voltage
1.5 m length cable from E5ZE to Display Unit, RS-232C with 25-pin connector
1.5 m length cable from E5ZE to Display Unit, RS-232C with 9-pin connector
50 A load, 5.8 mm hole dia.
120 A load, 12 mm hole dia.
For setup and monitoring
2 m length cable connects XW2B-20G4 or XW2B-20G5 screw terminals for
control and current transformer inputs and alarm outputs; order 3 cables
Color-coded terminals assure correct wiring; plugs into DeviceNet port; order 2
One-branch, T-branch tap with three connectors
Three-branch, T-branch tap with five connectors
Terminal block with terminating resistor: 121 W
Control
Control
output
output
Voltage
Voltage
Current
Voltage
Voltage
Current
Heater open circuit/
Heater open circuit/
SSR fault detection
SSR fault detection
Yes (See Note 2)
No
No
Yes (See Note 2)
No
No
Part number
Thermocouple
E5ZE-8AQHD1TCB-V2
E5ZE-8AQAD1TCB-V2
E5ZE-8ACAD1TCB-V2
E5ZE-8VQHD1TCB-V2
E5ZE-8VQAD1TCB-V2
E5ZE-8VCAD1TCB-V2
E5ZE-8j j D1j j B-V2
Platinum resistance thermometer
E5ZE-8AQHD1PB-V2
E5ZE-8AQAD1PB-V2
E5ZE-8ACAD1PB-V2
E5ZE-8VQHD1PB-V2
E5ZE-8VQAD1PB-V2
E5ZE-8VCAD1PB-V2
Part number
E5ZD-SDL1 AC100-240
E5ZD-SDL1 DC24
ES100-CT022-202
ES100-CT023-202
E54-CT1
E54-CT3
SYS-CONFIG V2.0
E5ZE-CBL200
XW4B-05C1-H1-D
DCN1-1C
DCN1-3C
DRS1-T
1

E5ZE-8VQAD1TCB-V2 DC24 Summary of contents

Page 1

... RS-232C connection; 24 VDC supply voltage programming without programming without 1.5 m length cable from E5ZE to Display Unit, RS-232C with 25-pin connector software; 1/4 DIN size software; 1/4 DIN size 1.5 m length cable from E5ZE to Display Unit, RS-232C with 9-pin connector Current transformer ...

Page 2

... E5ZE-8V V D1V V B- max. 100 kW min. 2 VDC max max. Setting (See Note 1) Minimum units 0 1_C or 0.1_C 1_C or 0.1_C 1 2 ...

Page 3

... IP00 Weight Case-type Unit: 1,700 g max. Note: 1. The measurement accuracy of the E5ZE used with a thermocouple B at 400°C or 750°F max. is not guaranteed. The following measurement accuracy values are applied to the E5ZE. K and T at --100°C max. and U: K and T at --100°F max. and and W at 200° ...

Page 4

... This product has been tested by ODVA’s authorized Independent Test Lab and found to comply with ODVA Conformance Test Software Version 2.0-1.00. For the specifications of objects in details, refer to the E5ZE-8 Multi-point Temperature Controller Communications Manual (H114). CompoBus/D Communications Items Remote I/O communications ...

Page 5

... The bank number that has been selected is displayed. Lit at the time of key shift. Lit when the displayed unit is being controlled. Flashes while auto-tuning is being executed. Lit when heater burnout or heater short circuit alarm output is ON. Lit when alarm output 1 is ON. Lit when alarm output 2 is ON. E5ZE-8V V D1V V B-V2 5 ...

Page 6

... Maximum point : All points Maximum unit : All units All banks connection when the E5ZE is mounted to equipment. Host Unit Compatible with Explicit Messaging Communications Explicit messaging can be used with many different manufacturers Device- Net Master units OMRON’s CS1W-DRM21 and CJ1W-DRM21 Note 1. When not communicating using the ...

Page 7

... Use flat washers and spring washers with screws to mount the E5ZE to control panels so that the screws will not loosen. The mounting brackets must be attached to the E5ZE with the four screws provided with the E5ZE and each of the screws should be tightened to a torque of 0. 4.4 to 5.9 kgf S cm. ...

Page 8

... One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. H103-E3-2 11/01 8 OMRON ON- -LINE Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci Specifications subject to change without notice. E5ZE-8V V D1V V B-V2 OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in U.S.A. ...