METER RATE INDICATION 6-DIGIT

PAXLR000

Manufacturer Part Number
PAXLR000
Description
METER RATE INDICATION 6-DIGIT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Rate Indicatorr
Datasheets

Specifications of PAXLR000

Count Rate
25kHz
Number Of Digits/alpha
6
Input Type
Logic, Transistor
Voltage - Supply
10 V ~ 16 VDC,115 VAC, 230 VAC
Display Type
LED
No. Of Digits / Alpha
6
Signal Input Type
Pulse
Character Size
0.56"
Ip/nema Rating
IP65 / NEMA 4X
Panel Cutout Height
1.77"
Display Font Color
Red
Panel Cutout Width
3.62"
Accuracy
±0.01% %
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Digit Height
0.56
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Function
Rate Indicator
Number Of Digits
6
Primary Type
Electronic
Range, Measurement
0.01 Hz to 25 kHz
Termination
Terminal Block
Voltage, Supply
115/230 VAC
Counter Supply Voltage
115/230VAC/10-16VDC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
RLC103
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL PAXLR - PAX
GENERAL DESCRIPTION
flexibility needed to accommodate virtually any rate measuring application. The
meter has the ability to scale for direct readout in terms of the units being
measured. Whether a machine produces bottles, cloth, wire, or beverage mix,
operation is enhanced when the rate readout is expressed directly in bottles/min.,
feet/min., gallons/min., or whatever units are needed in plant applications.
open collector sensors. The pulses are received and scaled, so the desired
display can be achieved. The meter is programmed through both the front panel
buttons and DIP switches. Once the programming is complete, the front panel
buttons can be disabled by a DIP switch setting.
With NEMA 4X/IP65 sealed bezel and extensive testing to meet CE
requirements, the meter provides a tough, yet reliable application solution.
C C
DIMENSIONS In inches (mm)
The PAX
The PAXLR can accommodate magnetic pickups, logic sensors, and NPN
The meter has been specifically designed for harsh industrial environments.
U L
R
8. 8 . 8 . 8 . 8 . 8
®
Lite Rate Meter, Model PAXLR, provides the versatility and
PAR
US LISTED
US LISTED
(96.5)
3.80
IND. CONT. EQ.
51EB
(49.5)
1.95
(2.5)
.10
®
LITE RATE METER
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is
2.1" (53.4) H x 5" (127) W.
(104.1)
4.10
1
SAFETY SUMMARY
literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
 RATE INDICATION
 6-DIGIT, 0.56" (14.2 mm) HIGH RED LED DISPLAYS
 INPUT RATES UP TO 25 KHZ
 ACCEPTS A WIDE VARIETY OF SENSORS
 PROGRAMMABLE SCALING
 PROGRAMMABLE UPDATE TIME
 PROGRAMMABLE DECIMAL POINTS
 NEMA 4X/IP65 SEALED FRONT BEZEL
All safety related regulations, local codes and instructions that appear in the
installation and operation of the unit.
Read complete instructions prior to
CAUTION: Risk of Danger.
(44.5)
1.75
1
2
3
4
5 6
3.60 (91.4)
7
8
9
CAUTION: Risk of electric shock.
10
Bulletin No. PAXLR-D
Drawing No. LP0564
Released 03/10
(44.5)
1.75

PAXLR000 Summary of contents

Page 1

Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL PAXLR - PAX LISTED US LISTED R IND. CONT. EQ. 51EB GENERAL DESCRIPTION ® The PAX Lite Rate Meter, Model PAXLR, provides the versatility and ...

Page 2

ABLE F ONTENTS Ordering Information . . . . . . . . . . . . . . . . . . . . 2 General Meter Specifications . . . . . . . . ...

Page 3

G M ENERAL ETER 1. DISPLAY: 6-digit, 0.56" (14.2 mm), 7-segment red LED. Decimal points are programmed by front panel keys. 2. POWER: AC Power: 115/230 VAC, switch selectable. Allowable power line variation ±10%, 50/60 Hz, 6 VA. @ 100 ...

Page 4

S ETTING THE The meter has switches that must be checked and/or changed prior to applying power. To access the power switch, remove the meter base from the case by firmly squeezing and pulling back on the side rear ...

Page 5

POWER WIRING AC Power DC Power Terminal 1: VAC Terminal 3: +VDC Terminal 2: VAC Terminal 4: COMM 1 2 3.2 INPUT WIRING Magnetic Pickup MAGNETIC PICKUP Current Sinking Output ...

Page 6

R EVIEWING THE KEY DISPLAY MODE OPERATION PAR Access Programming Mode  No Function  No Function 5.0 S CALING THE RATE SCALING To scale the Rate, enter a Scaling Display value with a corresponding Scaling Input value. These ...

Page 7

P ROGRAMMING THE RATE DISPLAY PAR Pro PAR dEC Pt Decimal Position The Rate Indicator has five programmable parameters which are entered in the sequence shown above, using the front panel push buttons. Before programming, refer to the section ...

Page 8

... The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property ...