CUB7W010 Red Lion Controls, CUB7W010 Datasheet

COUNTER 8-DIGIT YEL BKLT VOLT-IN

CUB7W010

Manufacturer Part Number
CUB7W010
Description
COUNTER 8-DIGIT YEL BKLT VOLT-IN
Manufacturer
Red Lion Controls
Series
CUB7r
Datasheet

Specifications of CUB7W010

Count Rate
30Hz
Number Of Digits/alpha
8
Input Type
Voltage
Voltage - Supply
9 V ~ 28 V
Display Type
LCD Backlit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Other names
RLCW71
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL CUB7W - MINIATURE ELECTRONIC 8 DIGIT COUNTER
DESCRIPTION
mm) high digits. It has an LCD read-out available in Positive Image Reflective,
Negative Image Transmissive with yellow/green backlighting or red
backlighting. The backlight versions require an external 9 to 28 VDC power
supply.
plated substrate, that is electrically connected by ultrasonic wire-bonding.
Proven micro-electronic assembly and manufacturing techniques provide these
units with the reliability and dependability required for industrial service.
clear viewing window. The sealed front panel with the silicone rubber reset
button meets NEMA 4X/IP65 specifications for wash-down and/or dusty
environments, when properly installed.
ORDERING INFORMATION
*Battery is included with unit.
For more information on Pricing, Enclosures & Panel Mount Kits refer to the
RLC Catalog or contact your local RLC distributor.
DIMENSIONS In inches (mm)
MODEL NO.
CUB7W *
OR RED LED BACKLIGHTING (9-28 VDC power supply required for
versions with LED backlighting)
7 YEARS OF UNINTERRUPTED OPERATION
TERMINALS
(22.2 mm)
The CUB7 series is an 8-digit miniature counter with large 0.35 inch (8.90
The CUB7 series use a CMOS LSI counter circuit chip, mounted on a gold-
The CUB7 series is housed in a lightweight, high impact plastic case with a
LCD, REFLECTIVE OR TRANSMISSIVE WITH YELLOW/GREEN
0.35" (8.90 mm) HIGH DIGITS
REPLACEABLE INTERNAL LITHIUM BATTERY PROVIDES UP TO
NEMA 4X/IP65 SEALED FRONT BEZEL
COUNT INPUT FROM 10 to 300 VAC/DC (CUB7W)
WIRE CONNECTION MADE VIA SCREW CLAMP TYPE
FITS DIN STANDARD CUT-OUT 1.77" (45 mm) x 0.874"
BNL
DESCRIPTION
Counter Positive Image Reflective
Counter w/Yel-Grn Backlighting
Counter w/Red Backlighting
3 V Lithium Battery
PART NUMBERS
CUB7W000
CUB7W010
CUB7W020
BNL10000
Note: Recommended minimum clearance (behind the panel) for mounting
clip installation is 2.15" (54.6) H x 3.00" (76.2) W.
1
SAFETY SUMMARY
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
not equipped with safeguards. To do so, can be potentially harmful to persons
or equipment in the event of a fault to the unit.
SPECIFICATIONS
1. DISPLAY: 8-digit LCD, 0.35" (8.90 mm) high digits.
2. POWER SOURCE: Replaceable Internal 3.0 V lithium battery to provide up
3. BACKLIGHT POWER REQUIREMENTS: 9 to 28 VDC; 35 mA. typical,
4. INPUTS: V
5. REMOTE RESET: 15 msec min. pulse width (active low) from 3.0 V
All safety related regulations, local codes and instructions that appear in the
Do not use this unit to directly command motors, valves, or other actuators
to 7 years of continuous operation. (Battery life is dependent upon usage.
Count and reset contacts that remain closed for long periods of time reduce
battery life.)
50 mA max. Above 26 VDC, derate max. operating temperature to 40°C.
bipolar output, an open collector transistor, or a switch contact to common.
Low speed input: 10 to 300 VAC/DC, 50/60 Hz, 30 cps max. 150 V max
for backlight versions. Unit counts on positive going edge.
IL
(low) = 0.5 V max
installation and operation of the unit.
Read complete instructions prior to
CAUTION: Risk of Danger.
PANEL CUT-OUT
Bulletin No. CUB7W-B
Drawing No. LP0601
Released 2/08

CUB7W010 Summary of contents

Page 1

... PART NUMBERS to 7 years of continuous operation. (Battery life is dependent upon usage. CUB7W000 Count and reset contacts that remain closed for long periods of time reduce CUB7W010 battery life.) 3. BACKLIGHT POWER REQUIREMENTS VDC; 35 mA. typical, CUB7W020 50 mA max. Above 26 VDC, derate max. operating temperature to 40°C. ...

Page 2

CERTIFICATIONS AND COMPLIANCES: SAFETY IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use, Part 1. IP65 Enclosure rating (Face only), IEC 529 Type 4X Enclosure rating (Face only), UL50 ELECTROMAGNETIC COMPATIBILITY Immunity to ...

Page 3

L. S. INPUT, 30 CPS MAX. The CUB7W accepts most machine control voltage signals. The input accepts AC (50/60 Hz control voltages from 10 to 300 V at count speeds cps. The unit counts on ...

Page 4

... The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property ...