... S-Bus, ACTION PIN* connectors and product intended for term ination to .025 inch centerline ribbon cable and surface m ount product. 1.2. Qualification W hen tests are perform ed on subject product line, procedures specified in Figure 1 shall be used. All inspections shall be perform ed using the applicable inspection plan and product drawing. 2. APPLICABLE DOCUM ENTS The following TE Connectivity (TE) docum ents form a part of this specification to the extent specified herein ...
Page 2
... Perform ance and Test Description Product is designed to m eet the electrical, m echanical and environm ental perform ance requirem ents specified in Figure 1. Unless otherwise specified, all tests shall be perform bient environm ental conditions per Test Specification 109-1. 3.5. Test Requirem ents and Procedures Sum m ary Test Description Exam ination of product ...
Page 3
... Procedure TE Spec 109-42, Condition A. Measure force necessary to m ate sam ples without locking latches at m axim um rate of 1 inch per m inute. TE Spec 109-42, Condition A. Measure force necessary to unm ate sam ples without locking latches at m axim um rate of 1 inch per m inute. ...
Page 4
... Tem perature life Mixed flowing gas (a) See paragraph 4.1.A. NOTE (b) Numbers indicate sequence in which tests are performed. (c) No wires or printed circuit boards used with test sequence 4. (d) Precondition samples with 10 cycles durability. Rev F RECEPTACLE # Denotes energized circuit Figure 2 Current Energizing Circuit Test Group ( ...
Page 5
... Acceptance Acceptance is based on verification that the product m eets the requirem ents of Figure 1. Failures attributed to equipm ent, test setup or operator deficiencies shall not disqualify the product. W hen product failure occurs, corrective action shall be taken and sam ples resubm itted for qualification. ...
Page 6
... Certification Product has been recognized under the Com ponent Recognition Program of Underwriters' Laboratories Inc., Electrical File num ber E-28476, and certified by Canadian Standards, File Num ber LR-86179-1. Note: Voltage drop due to “X” of wire rem oved from all readings. Term ination Resistance Measurem ent Points ...
Page 7