DS1013M-40 Maxim Integrated Products, DS1013M-40 Datasheet - Page 6

DELAY LINE 3TAP 40NS MAX 8-DIP

DS1013M-40

Manufacturer Part Number
DS1013M-40
Description
DELAY LINE 3TAP 40NS MAX 8-DIP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1013M-40

Function
Multiple
Delay To 1st Tap
40nS
Available Total Delays
40, 40, 40ns
Number Of Independent Delays
3
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Taps/steps
-
Tap Increment
-
Other names
DS1013M40

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS1013M-40
Manufacturer:
DALLAS
Quantity:
5 510
Part Number:
DS1013M-40
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS1013M-40+
Manufacturer:
DALLAS
Quantity:
20 000
TEST SETUP DESCRIPTION
Figure 3 illustrates the hardware configuration used for measuring the timing parameters on the DS1013.
The input waveform is produced by a precision pulse generator under software control. Time delays are
measured by a time interval counter (20 ps resolution) connected between each input and corresponding
output. Each output is selected and connected to the counter by a VHF switch control unit. All
measurements are fully automated, with each instrument controlled by a central computer over an IEEE
488 bus.
TEST CONDITIONS
INPUT:
Ambient Temperature:
Supply Voltage (V
Input Pulse:
Source Impedance:
Rise and Fall Time:
Pulse Width:
Period:
OUTPUT:
Each output is loaded with the equivalent of one 74F04 input gate. Delay is measured at the 1.5V level on
the rising and falling edge.
NOTE:
Above conditions are for test only and do not restrict the operation of the device under other data sheet
conditions.
CC
):
5.0V ± 0.1V
High = 3.0V ± 0.1V
Low = 0.0V ± 0.1V
3.0 ns Max.
500 ns
25°C ± 3°C
50 ohms Max.
1 µs
6 of 6
DS1013

Related parts for DS1013M-40