AD7986BCPZ Analog Devices Inc, AD7986BCPZ Datasheet - Page 22

IC ADC 18BIT 2MSPS SAR 20LFCSP

AD7986BCPZ

Manufacturer Part Number
AD7986BCPZ
Description
IC ADC 18BIT 2MSPS SAR 20LFCSP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7986BCPZ

Data Interface
MICROWIRE™, QSPI™, Serial, SPI™
Number Of Bits
18
Sampling Rate (per Second)
2M
Number Of Converters
1
Power Dissipation (max)
34mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-VFQFN, CSP Exposed Pad
Resolution (bits)
18bit
Sampling Rate
2MSPS
Input Channel Type
Differential
Supply Voltage Range - Analog
2.375V To 2.625V
Digital Ic Case Style
CSP
No. Of Pins
20
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7986BCPZ
Manufacturer:
Allen Bradlley
Quantity:
100
Part Number:
AD7986BCPZ
Manufacturer:
Analog Devices Inc
Quantity:
135
AD7986
CS MODE, 4-WIRE WITH BUSY INDICATOR
This mode is usually used when a single AD7986 is connected
to an SPI-compatible digital host with an interrupt input and
when it is desired to keep CNV, which is used to sample the
analog input, independent of the signal used to select the data
reading. This independence is particularly important in
applications where low jitter on CNV is desired. This mode is
only available in normal conversion mode (TURBO = low).
The connection diagram is shown in Figure 31, and the
corresponding timing is given in Figure 32.
With SDI high, a rising edge on CNV initiates a conversion,
selects the CS mode, and forces SDO to high impedance. In this
mode, CNV must be held high during the conversion phase and
the subsequent data readback. (If SDI and CNV are low, SDO is
driven low.) Prior to the minimum conversion time, SDI can be
TURBO = 0
ACQUISITION
SDO
CNV
SCK
SDI
t
SSDICNV
t
HSDICNV
CONVERSION
t
CONV
Figure 32. CS Mode, 4-Wire with Busy Indicator Serial Interface Timing
Figure 31. CS Mode, 4-Wire with Busy Indicator Connection Diagram
t
EN
SDI
AD7986
CNV
SCK
1
Rev. B | Page 22 of 28
t
t
HSDO
DSDO
TURBO
SDO
D17
2
VIO
t
47kΩ
CYC
D16
used to select other SPI devices, such as analog multiplexers,
but SDI must be returned low before the minimum conversion
time elapses and then held low for the maximum possible
conversion time to guarantee the generation of the busy signal
indicator. When the conversion is complete, SDO goes from
high impedance to low impedance. With a pull-up on the SDO
line, this transition can be used as an interrupt signal to initiate
the data readback controlled by the digital host. The AD7986
then enters the acquisition phase and powers down. The data
bits are then clocked out, MSB first, by subsequent SCK falling
edges. The data is valid on both SCK edges. Although the rising
edge can be used to capture the data, a digital host using the
SCK falling edge allows a faster reading rate, provided that it
has an acceptable hold time. After the optional 19
edge or SDI going high (whichever occurs first), SDO returns to
high impedance.
3
ACQUISITION
CONVERT
DATA IN
CLK
CS1
IRQ
DIGITAL HOST
t
ACQ
t
SCKL
t
SCKH
17
t
SCK
18
D1
19
D0
(I/O QUIET
TIME)
t
DIS
t
QUIET
th
SCK falling

Related parts for AD7986BCPZ