4-644381-1 TE Connectivity, 4-644381-1 Datasheet

11P MTA156 QUAD ASSY,W/TBS C/E

4-644381-1

Manufacturer Part Number
4-644381-1
Description
11P MTA156 QUAD ASSY,W/TBS C/E
Manufacturer
TE Connectivity
Datasheets

Specifications of 4-644381-1

Connector Type
Connector Assembly
Connector Design
Closed End
Product Line
MTA-156
Termination Method To Wire/cable
IDC Standard
Wire Size (mm² [awg])
0.8-0.9² [18]
Mating Connector Lock
With
Four Points Of Contact
With
Shrouded
No
Mounting Ears
Without
Mating Connector Lock Type
Locking Ramp
Panel Mount Retention
Without
Solder Tail Contact Plating
Bright Tin
Number Of Positions
11
Centerline (mm [in])
3.96 [0.156]
Narrow
No
Post Number(s) Omitted
None
Cable Exit Angle
90°
Contact Type
Socket
Contact Plating, Mating Area, Material
Tin
Contact Base Material
High Conductivity Copper Alloy
Connector Style
Receptacle
Housing Color
Black
Mating Alignment
With
Ul Flammability Rating
UL 94V-0
Housing Material
Nylon
Mating Alignment Type
Polarizing Tab
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Applies To
Wire/Cable
Application Use
Wire-to-Board
1.
1.1.
1.2.
2.
3.
3.1.
3.2.
©2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. Company
All Rights Reserved
TE logo is a trademark.
SCOPE
Content
This specification covers performance, tests and quality requirements for the TE Connectivity (TE)
MTA-.156 Quad Contact connector system. This connector system can be mass or single wire
terminated utilizing insulation displacement technology on .156 inch centerlines and mates with .045
inch square posts. This system provides a reliable interconnection between wires and posts mounted
on printed circuit boards. Quad connector is available in 2 through 12 positions. This connector system
is designed to be terminated to 18, 20 and 22 AWG wire, solid, stranded and prefused or overcoated
wire, tin plated, UL style 1007, 1061 or wire which specifies PVC insulation with temperature rating
compatible with specified operating temperatures, see Figure 4A. Wire shall be applied per application
requirements specified in Application Specification 114-1048. Wire insulation diameter shall be .070
inch maximum OD for mass terminated wire and .095 inch maximum OD for single terminated wire.
Qualification
When tests are performed on the subject product line, procedures specified in Figure 1 shall be used.
All inspections shall be performed using the applicable inspection plan and product drawing.
APPLICABLE DOCUMENTS
The following Tyco Electronics documents form a part of this specification to the extent specified herein.
Unless otherwise specified, the latest edition of the document applies. In the event of conflict between
the requirements of this specification and the product drawing, the product drawing shall take
precedence. In the event of conflict between the requirements of this specification and the referenced
documents, this specification shall take precedence.
!
!
!
!
REQUIREMENTS
Design and Construction
Product shall be of the design, construction and physical dimensions specified on the applicable product
drawing.
Materials
!
!
!
!
109-1: General Requirements for Test Specifications
109 Series: Test Specifications as indicated in Figure 1
114-1048: Application Specification
501-247: Test Report
Contact: Copper alloy, bright tin-lead plated, lubricated
Headers: Thermoplastic polyester, UL94V-0
Header post: Brass, .045 inch square, tin plated
Housing: Nylon 6/6, black, UL94V-0
| Indicates change
*Trademark
Product
Specification
Connector System, MTA 156 Quad
For latest revision, visit our website at www.te.com/documents.
For Regional Customer Service, visit our website at www.te.com
Other products, logos, and company names might be trademarks of their respective owners.
108-1219
11Mar11 Rev C
1 of 10
LOC B

Related parts for 4-644381-1

4-644381-1 Summary of contents

Page 1

... AWG wire, solid, stranded and prefused or overcoated wire, tin plated, UL style 1007, 1061 or wire which specifies PVC insulation with temperature rating compatible with specified operating temperatures, see Figure 4A. Wire shall be applied per application requirements specified in Application Specification 114-1048. Wire insulation diameter shall be .070 inch maximum OD for mass terminated wire and ...

Page 2

... Ratings ! Voltage: 600 volts AC ! Current: See Figure 4 for applicable current carrying capability ! Temperature: -55 to 105° C 3.4. Performance and Test Description Product is designed to meet the electrical, mechanical and environmental performance requirements specified in Figure 1. All tests are performed at ambient environmental conditions per Test Specification 109-1 unless otherwise specified ...

Page 3

... TE Spec 109-30. Pull on contacts using special housing cut away to expose contact top for gripping. TE Spec 109-42, Condition A. Measure force necessary to mate connector assemblies with tin plated plain flat header a distance of 0.20 inch from point of initial contact using free floating fixtures at rate of 0 ...

Page 4

... Contact retention Mating force Unmating force Thermal shock Humidity-temperature cycling Temperature life (a) See paragraph 4.1.A. NOTE (b) Numbers indicate sequence in which tests are performed. (c) Discontinuities shall not be measured. Energize at 18 determined in Test Specification 109-151. (d) One half samples shall be subjected to straight slot test with remaining half subjected to perpendicular tensile test ...

Page 5

... Test group 4 shall consist of minimum of 30 contacts from minimum of 3 connectors for maximum wire size. Test groups 1 and 9 shall be mounted per Figure 5. Test groups 2, 3 and 6 shall be mounted per Figure 4. Test groups 4 and 7 shall be mounted per Figure 6. All wires shall be applied per AMP Specification 114-1048 ...

Page 6

... Termination resistance equals millivolts drop divided by test current less resistance of total NOTE length of wire. 2. After wave soldering, board and posts shall be cleaned to remove all flux and contaminates. Resistance & Temperature Measurement Points Rev C Figure 3 PCB 93-660164 108-1219 ...

Page 7

... Single Circuit, I Operating temperature is defined as ambient temperature plus current produced temperature rise NOTE in contact system. Operating temperature in above graph is area under curve. Rev AWG, Continuous Operating RMS DC (95% Probability and 99% Reliability) Figure 4A Current Carrying Capability 108-1219 ...

Page 8

... Figure 4B Current Rating 108-1219 Position Size ...

Page 9

... Rev C Figure 5 Vibration & Physical Shock PCB 93-660164 108-1219 ...

Page 10

Rev C Figure 6 Vibration & Current Cycling PCB 93-660092-1 108-1219 ...

Related keywords