4-644695-1 TE Connectivity, 4-644695-1 Datasheet - Page 4

11P MTA100 STR HDR RETENTIVE

4-644695-1

Manufacturer Part Number
4-644695-1
Description
11P MTA100 STR HDR RETENTIVE
Manufacturer
TE Connectivity
Datasheets

Specifications of 4-644695-1

Connector Type
Header
Product Line
MTA-100
Pcb Mounting Orientation
Vertical
Pcb Mount Retention
With
Mating Connector Lock
Without
Four Points Of Contact
Without
Shrouded
No
Mounting Ears
Without
Post Size (mm [in])
0.64 [.025]
Panel Mount Retention
Without
Voltage Rating (vac)
250
Solder Tail Contact Plating
Tin
Number Of Positions
11
Centerline (mm [in])
2.54 [0.100]
Narrow
Yes
Post Number(s) Omitted
None
Pcb Mount Retention Type
Boardlock(s)
Contact Type
Pin
Contact Shape
Square
Contact Plating, Mating Area, Material
Tin
Contact Base Material
Copper Alloy
Connector Style
Plug
Housing Color
White
Mating Alignment
Without
Ul Flammability Rating
UL 94V-0
Housing Material
Polyester
Backwall/post Interruption(s)
Without
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Wave solder capable to 240°C
Rohs/elv Compliance History
Always was RoHS compliant
Applies To
Printed Circuit Board
Application Use
Wire-to-Board
3.6.
Rev H
Product Qualification and Requalification Test Sequence
NOTE
(a) See paragraph 4.1.A.
(b) Numbers indicate sequence in which tests are performed.
(c)
(d) Gold plated samples.
(e) Discontinuities shall not be measured. Energize at 18
(f)
(g) Precondition samples with 5 cycles durability.
Examination of product
Termination resistance
Insulation resistance
Dielectric withstanding voltage
Temperature rise vs current
Solderability
Termination tensile strength
Vibration
Physical shock
Durability
Mating force
Unmating force
Thermal shock
Humidity-temperature cycling
Temperature life
Mixed flowing gas
Tin-lead plated samples.
Test Specification 109-151.
Subject half the samples to the parallel tensile test and the remaining half to the
perpendicular tensile test.
Test or Examination
Figure 2
1,9
3,7
1
5
6
4
2
8
2(c)
6(e)
4(g)
1,9
2,7
3,8
5
Test Sequence (b)
Test Group (a)
3(d)
3(g)
1,5
2,4
1,8
2,6
3,7
4
4
5
E
C level for 100% loadings per
2(f)
1,3
5
1,3
6
2
108-1050
4 of 9

Related parts for 4-644695-1