5-6610138-1 TE Connectivity, 5-6610138-1 Datasheet - Page 5

1X5 MAG45(TM) 7H2,66,CAP,G/Y R

5-6610138-1

Manufacturer Part Number
5-6610138-1
Description
1X5 MAG45(TM) 7H2,66,CAP,G/Y R
Manufacturer
TE Connectivity
Datasheets

Specifications of 5-6610138-1

Product Type
Connector
Number Of Cores
6
Magnetics
Integrated Magnetics
Jack Type
RJ45
Signal Routing Type
Auto MDI/MDIX
Profile
Standard
Pcb Mounting Orientation
Side Entry (Right Angle)
Jack Configuration
1 x 5
Turns Ratio
1:1
Shielded
Yes
Emi Finger - Bottom
With
Termination Method
Solder
Port Configuration
Multiple
Emi Fingers -top And Sides
Without
Latch Orientation
Inverted - Latch Up
Pcb Tail Length (mm [in])
3.68 [0.145]
Contact Termination Type
Through Hole
Preloaded
Yes
Connector Style
Jack
Status Indicator
LED
Decoupling Capacitor
2KV
Rear Pcb Ground Tab
With
Signal Lead Quantity
8
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Wave solder capable to 240°C, Wave solder capable to 260°C, Wave solder capable to 265°C
Rohs/elv Compliance History
Always was RoHS compliant
Left Led Color (position #1)
Green - 250 ohm resistor
Right Led Color (position #2)
Yellow - 250 ohm resistor
Operating Temperature (°c [°f])
0 – 70 [32 – 158]
Applies To
Printed Circuit Board
Environmental Conditions
Office / Premises
Application
10/100BASE-T Ethernet
4.
4.1.
4.2.
4.3.
4.4.
Rev D
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form, fit or function are made to the product or manufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determined by development/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that the product meets the requirements of Figure 1. Failures
attributed to equipment, test setup or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specimens resubmitted for qualification. Testing to
confirm corrective action is required before resubmittal.
Quality Conformance Inspection
The applicable quality inspection plan shall specify the sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with the applicable product drawing
and this specification.
Specimen Selection
Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be
selected at random from current production. Test group 1 shall consist of 16 specimens. Test
groups 2 and 3 shall each consist of 1 specimen. Test group 4 shall consist of 45 specimens.
Test Sequence
Qualification inspection shall be verified by testing specimens as specified in Figure 2.
108-2100
5 of 6