MAX1030BEEG+ Maxim Integrated Products, MAX1030BEEG+ Datasheet - Page 18

IC ADC 10BIT 300KSPS 24-QSOP

MAX1030BEEG+

Manufacturer Part Number
MAX1030BEEG+
Description
IC ADC 10BIT 300KSPS 24-QSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX1030BEEG+

Number Of Bits
10
Sampling Rate (per Second)
300k
Data Interface
MICROWIRE™, QSPI™, Serial, SPI™
Number Of Converters
1
Power Dissipation (max)
762mW
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-QSOP
Number Of Adc Inputs
16
Architecture
SAR
Conversion Rate
300 KSPs
Resolution
10 bit
Input Type
Differential
Interface Type
3-Wire (SPI, QSPI, MICROWIRE)
Voltage Reference
Internal 4.096 V or External
Supply Voltage (max)
5 V
Maximum Power Dissipation
762 mW
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
10-Bit 300ksps ADCs with FIFO,
Temp Sensor, Internal Reference
In clock mode 10, the wake-up, acquisition, conversion,
and shutdown sequences are initiated by writing an
input data byte to the conversion register, and are per-
formed automatically using the internal oscillator. This
is the default clock mode upon power-up. See Figure 6
for clock mode 10 timing.
Figure 5. Clock Mode 01
18
Figure 6. Clock Mode 10
CNVST
SCLK
DOUT
EOC
DIN
SCLK
DOUT
EOC
CS
CS
______________________________________________________________________________________
(ACQUISITION1)
Conversions Using the Serial Interface
THE CONVERSION BYTE BEGINS THE ACQUISITION. CNVST IS NOT REQUIRED. X = DON'T CARE.
REQUEST MULTIPLE CONVERSIONS BY SETTING CNVST LOW FOR EACH CONVERSION. X = DON'T CARE.
(CONVERSION1)
Performing Conversions in Clock Mode 10
Internally Timed Acquisitions and
(ACQUISITION2)
(CONVERSION BYTE)
(CONVERSION2)
(UP TO 514 INTERNALLY CLOCKED ACQUISITIONS AND CONVERSIONS)
MSB1
MSB1
Initiate a scan by writing a byte to the conversion regis-
ter. The MAX1026/MAX1028/MAX1030 then power up,
scan all requested channels, store the results in the
FIFO, and shut down. After the scan is complete, EOC
is pulled low and the results are available in the FIFO. If
a temperature measurement is requested, the tempera-
ture result precedes all other FIFO results. EOC stays
low until CS is pulled low again.
LSB1
LSB1
MSB2
MSB2

Related parts for MAX1030BEEG+