KUP-5D55-24 TE Connectivity, KUP-5D55-24 Datasheet - Page 2

no-image

KUP-5D55-24

Manufacturer Part Number
KUP-5D55-24
Description
POWER RELAY, SPDT, 24VDC, 10A, BRACKET
Manufacturer
TE Connectivity
Series
KUPr
Datasheet

Specifications of KUP-5D55-24

Relay Type
General Purpose
Coil Voltage Vdc Nom
24V
Contact Current Max
10A
Contact Voltage Ac Nom
240V
Contact Voltage Dc Nom
32V
Coil Resistance
472ohm
Contact Configuration
SPDT
Rohs Compliant
Yes
Brand/series
KUP Series
Contact Form
SPDT
Current, Rating
10 A
Dimensions
1.532 in. L x 1.406 in. W x 1.907 in. H
Function
General Purpose
Material, Contact
Silver Cadmium Oxide
Mounting Type
Bracket
Number Of Pins
9
Resistance, Coil
472 Ohms
Standards
UL, CSA, RoHS
Termination
Quick Connect
Tyco Part Number
7-1393118-1
Voltage, Control
24 VDC
Voltage, Rating
300 VAC
Coil Voltage
24 V
Coil Current
51 mA
Contact Rating
10 A
Contact Termination
Solder
Mounting Style
Bracket Mount
Power Consumption
1.2 W
Contact Material
Silver Cadmium Oxide
Coil Type
Monostable
Lead Free Status / Rohs Status
RoHS Compliant part
724
Environmental Data (Continued)
Maximum Allowable Ambient Temperature vs. Voltage (KUP enclosed)
Dimensions are shown for
reference purposes only.
Ordering Information
Note: All part numbers are RoHS compliant.
Our authorized distributors are more likely to stock the following items for immediate delivery.
KUP-5A15-24
KUP-5A15-120
KUP-5A15-240
KUP-5A55-120
KUP-5D15-12
KUP-5D15-24
KUP-5D55-12
KUP-5D55-24
KUP-11A11-120
1. Basic Series & Type:
2.
3.
4.
5.
5A. Gold Flashed Contact Option:
6.
75°
70°
60°
50°
40°
30°
20°
Available
KU = Basic open relay.
KUP = Basic enclosed relay.
Contact Arrangement:
1 = 1A (SPST-NO)
5 = 1C (SPDT)
11 = 2C (DPDT)
Coil Input:
A = AC 50/60 Hz.
D = DC
Mountings:
OPEN STYLE
1 = #6-32 stud, .218" (5.54mm) locating tab.
3 = #6-32 tapped core, .125" (3.18mm) locating tab.
4 = #6-32 tapped core, .218" (5.54mm) locating tab.
Terminal & Contact Material:
1 = .187" (4.75mm) quick-connect/solder; silver, 5 amps.
5 = .187" (4.75mm) quick connect/solder; silver-cadmium oxide, 10 amps.
7 = .047” (1.19mm) printed circuit; silver-cadmium oxide, 10 amps.
9 = 4 pole KU, KUP: .110" (2.79mm) quick connect/solder; silver-cadmium oxide, 10 amps.
K = .250" (6.35mm) quick connect; silver-cadmium oxide, 10 amps.
F = Optional gold flashing for silver and silver-cadmium oxide contacts.
Coil Voltage:
To 240VAC, 50/60 Hz. or 110VDC.
Codes
100 110 120 130 140 150 160
Available
Type
Codes
Type
% of Nominal Voltage DC
1 & 2 Pole Models
1, 5, 7, K
KUP-11A15-12
KUP-11A15-24
KUP-11A15-120
KUP-11A15-240
KUP-11A35-120
KUP-11A55-24
KUP-11A55-120
KUP-11AT5-120
KUP-11D11-24
1,3,4
KU
14 = 3C (3PDT)
17 = 4C (4PDT)
3 Pole Models
1, 5, 7
75°
60°
50°
40°
30°
20°
Dimensions are in inches over
(millimeters) unless otherwise
specified.
70°
KUP-11D15-5
KUP-11D15-12
KUP-11D15-24
KUP-11D15-110
KUP-11D35-24
KUP-11D55-6
KUP-11D55-12
KUP-11D55-24
KUP-11D55-48
100
% Of Nominal 60 Hz. Voltage
Typical Part No.
110
4 Pole Models
1**, 5**,7, 9
120
KUP (through 3 poles)
Issued 3-03 (PDF Rev. 9-07)
* Indicator lamps are available on models with the following coils:
6-24VAC and DC, 110VDC and 120-240VAC. Only models with
120-240VAC coils are UL recognized.
130
Catalog 1308242
1 = PLAIN CASE;
2 = with test button.
3 = with indicator lamp.*
4 = with test button & indicator lamp.*
5 = BRACKET MOUNT CASE.
A = PLAIN CASE, #6-32 stud, locating tab.
E = PLAIN CASE, tapped core, locating tab.
T = TOP FLANGE CASE.
KUP-11D55-110
KUP-14A11-120
KUP-14A15-12
KUP-14A15-24
KUP-14A15-120
KUP-14A15-240
KUP-14A25-120
KUP-14A35-120
KUP-14A45-120
1,2,3,4,5,
>
140
A,E,T
**4 pole KUP with .187" (4.75mm) quick connect/solder
KU
KUP
terminals will not plug into sockets. Must use .110" (2.79
mm) quick connect solder terminals for socket mounting.
Specifications and availability
subject to change.
Mechanical Data
Termination: Quick connect, solder and PC board.
Enclosure: Clear polycarbonate dust cover.
Weight: 3.0 oz. (85g) approximately.
-14
KUP-14A55-24
KUP-14A55-120
KUP-14A55-240
KUP-14D11-24
KUP-14D15-6
KUP-14D15-12
KUP-14D15-24
KUP-14D15-48
KUP-14D15-110
KUP (4 pole models)
1,3,5,A,E
A
KUP-14D25-24
KUP-14D35-24
KUP-14D55-12
KUP-14D55-24
KUP-17A19-120
KUP-17A55-24
KUP-17D19-24
KUP-17D55-24
1
5
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
F
-120
P&B