IM46GR TE Connectivity, IM46GR Datasheet

RELAY, SMD, DPCO, 12VDC

IM46GR

Manufacturer Part Number
IM46GR
Description
RELAY, SMD, DPCO, 12VDC
Manufacturer
TE Connectivity
Datasheet

Specifications of IM46GR

Coil Type
DC
Contact Configuration
DPCO
Contact Current Max
2A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
220V
Coil Voltage Vdc Nom
12V
Coil Resistance
1.44kohm
Coil Power Cont
100mW
Relay
RoHS Compliant
AXICOM
Telecom-, Signal and RF Relays
IM Relay
108-98001 • Sep. 07 Rev. G • ECOC: JM10

Related parts for IM46GR

IM46GR Summary of contents

Page 1

... IM Relay 108-98001 • Sep. 07 Rev. G • ECOC: JM10 AXICOM Telecom-, Signal and RF Relays ...

Page 2

... AXICOM Telecom-, Signal and RF Relays IM Relay UL 508 File No. E 111441 UL 60950 IEC/EN60950 IEC Ref. Cert. No. 3270 All specifications subject to change. Consult Tyco Electronics for latest specifications. Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, ...

Page 3

... AXICOM Telecom-, Signal and RF Relays IM Relay Slim line AND low profile 2 pole telecom/signal relay, polarized Through Hole Types (THT), standard version with 5.08 mm, narrow version with 3.2 mm between the terminal rows or Surface Mount Type (SMT) Relay types: non-latching with 1 coil latching with 1 coil ROHS compliant (Directive 2002/95/EC) as per product date code 0438 ...

Page 4

... AXICOM Telecom-, Signal and RF Relays IM Relay Dimensions IM THT Standard mm inch L 10.00 ± 0.08 0.393 ± 0.003 W 6.00 ± 0.08 0.236 ± 0.003 H 5.65 – 0.20 0.222 – 0.008 T 3.2 0.125 T1 N/A N/A T2 5.08 ± 0.10 0.200 ± 0.004 D1 3.20 ± 0.15 0.126 ± ...

Page 5

... Upper limit of the operative range of the coil voltage (limiting voltage) when coils are continously energized = Lower limit of the operative range of the coil voltage (reliable operate voltage) For latching relays Uset min. resp. Ureset min. = Lower limit of the operative range of the coil voltage (reliable release voltage ...

Page 6

... AXICOM Telecom-, Signal and RF Relays IM Relay Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc Standard Version THT Standard non-latching 1 coil 1.5 1.13 3 2.25 4.5 3.38 5 3.75 6 4.50 9 6.75 12 9.00 24 18.00 THT Narrow non-latching 1 coil 1 ...

Page 7

... IM43JR 6-1462037-0 360 IM44JR 6-1462037-3 810 IM45JR 6-1462037-5 1440 IM46JR 6-1462037-8 2880 IM47JR 7-1462037-1 23 IM40GR 5-1462037-1 90 IM41GR 5-1462037-4 203 IM42GR 3-1462037-1 250 IM43GR 5-1462037-9 360 IM44GR 6-1462037-2 810 IM45GR 6-1462037-4 1440 IM46GR 6-1462037-7 2880 IM47GR 7-1462037-0 Tyco part number ...

Page 8

... AXICOM Telecom-, Signal and RF Relays IM Relay Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc High Sensitive Version SMT Gull Wings non-latching 1 coil 3 2.40 4.5 3.60 5 4.00 12 9.60 24 19.20 High Dielectric Version ...

Page 9

... AXICOM Telecom-, Signal and RF Relays IM Relay Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc Ultra High Sensitive Version SMT Gull Wings non-latching 1 coil 3 2.55 4.5 3.83 5 4.25 12 10.20 THT non-latching 1 coil 3 2 ...

Page 10

... AXICOM Telecom-, Signal and RF Relays IM Relay Contact Data Number of contacts and type Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting voltage Maximum switching capacity Thermoelectric potential Minimum switching voltage Initial contact resistance / measuring condition Electrical endurance at contact application 0 (≤ ...

Page 11

... AXICOM Telecom-, Signal and RF Relays IM Relay Insulation Insulation resistance at 500 Vdc Dielectric test voltage (1 min) between coil and contacts between adjacent contact sets between open contacts Surge voltage resistance according to Telcordia TR-NWT-001089 (2/10 µs) between coil and contacts between adjacent contact sets between open contacts according / EC 60950 (10/ 700 µ ...

Page 12

... AXICOM Telecom-, Signal and RF Relays IM Relay Recommended Soldering Conditions Soldering conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B sec 240 °C 180 °C 130 °C 100 °C Time (s) Recommended reflow soldering profile Time (s) Resistance to soldering heat - Reflow profile Time (s) All specifications subject to change. Consult Tyco Electronics for latest specifications. ...

Page 13

... All specifications subject to change. Consult Tyco Electronics for latest specifications. 108-98001 Rev. G Dimensions in mm Tube for THT version 50 relays per tube 1‘000 relays per box Tape and reel for SMT version 1’000 relays per reel 1’000 or 5’000 relays per box ...

Page 14

... Nominal voltage range from 3 ... 24 V, coil power consumption 65 mW, latching relays with 1 coil 30 mW. The P1 relay is available as through hole or surface mount type and capable to switch currents Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV – ...

Page 15

... D-13629 Berlin / Germany Phone +49 30 386 38573 Fax +49 30 386 38575 E-mail: axicom@tycoelectronics.com Tyco Electronics EC Trutnov s.r.o. Komenského 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.com AXICOM Telecom-, Signal and RF Relays Tyco Electronics Corporation Harrisburg, PA 17105, USA Phone +1 800-522-6752 POB 3608, ...