IM26GR TE Connectivity, IM26GR Datasheet - Page 3

RELAY, SMD, DPCO, 12VDC

IM26GR

Manufacturer Part Number
IM26GR
Description
RELAY, SMD, DPCO, 12VDC
Manufacturer
TE Connectivity
Datasheet

Specifications of IM26GR

Coil Type
DC, Sensitive
Contact Configuration
DPCO
Contact Current Max
2A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
220V
Coil Voltage Vdc Nom
12V
Coil Resistance
2.88kohm
Coil Power Cont
50mW
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IM26GR
Manufacturer:
TE
Quantity:
1 500
Slim line AND low profile
2 pole telecom/signal relay, polarized
Through Hole Types (THT), standard version
with 5.08 mm, narrow version with 3.2 mm between the
terminal rows or Surface Mount Type (SMT)
Relay types:
ROHS compliant (Directive 2002/95/EC) as per
product date code 0438.
Features
• Telecom/signal relay (dry circuit, test access,
• Slim line 10 x 6 mm, 0.39 x 0.24 inch
• Low profile 5.65 mm, 0.222 inch
• Minimum board-space 60 mm
• Switching current 2 A / 5 A
• 2 changeover contacts (2 form C / DPDT)
• Bifurcated contacts, gold plated
• High sensitivity results in low nominal power
• Ultra high sensitive type 50 mW for non latching
• High surge capability (1.2/50 µs and 10/700 µs)
• High mechanical shock resistance
• Hermetically sealed (RT V)
Typical applications
• Communications equipment
• Office and business equipment
• Measurement and control equipment
• Consumer electronics, Set top boxes, HiFi
• Medical equipment
Options
• Surge capability 2500 V between open contacts
All specifications subject to change. Consult Tyco Electronics for latest specifications.
ringing)
consumption
140 mW for non latching standard
100 mW for latching version and non latching high
sensitive version
meets Telcordia GR 1089, FCC Part 68 and ITU-T
K20, 21, 45
1500 V between open contacts
2500 V between coil and contacts
up to 300 G functional, up to 500 G survival
Linecard application – analog, ISDN, xDSL, PABX
Voice over IP
non-latching with 1 coil
latching with 1 coil
AXICOM
Telecom-, Signal and RF Relays
IM Relay
2
Insulation category
Supplementary insulation according
Working voltage
Mains supply voltage
Repetitive peak voltage
Pollution degree
Flammability classification
Maximum operating temperature
IEC / EN 60950
≤ 300 Vrms
≤ 250 Vrms
2500 V
Internal: 1
External: 2
V-0
85 °C
108-98001 Rev. G
3 of 15

Related parts for IM26GR